IPR Medical

Recertified

Philips IntelliVue M3001A Multi-Measurement Module | Option A02C06, Nellcor OxiMax SpO2, IBP & Temp

$1,095.00 Original price was: $1,095.00.$995.00Current price is: $995.00.

The Philips IntelliVue M3001A (Option A02C06) is the extended-measurement configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Nellcor OxiMax sensors. Building on the A02 standard package — ECG, arrhythmia, ST, respiration, Nellcor OxiMax-compatible SpO2, and oscillometric NBP — the C06 option adds a combined invasive pressure and temperature connector, enabling the module to support either invasive blood pressure monitoring or temperature measurement in addition to the full core parameter set. The A02C06 is the OxiMax-sensor equivalent of the A01C06, delivering an identical clinical measurement footprint while using a dedicated OxiMax-compatible SpO2 interface in place of the Philips FAST SpO2 circuit. This configuration is widely deployed in ICU, cardiovascular step-down, post-anesthesia care, and critical care transport environments where arterial line monitoring or core temperature tracking is routinely required alongside a Nellcor OxiMax sensor fleet. As with all M3001A variants, patient demographics, trend data, and measurement settings are stored in the module itself and travel with the patient between IntelliVue host monitors.

Part Number / Option M3001A, Option A02C06
Parameters Monitored ECG (3/5-lead), Arrhythmia, ST, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)
SpO2 Technology Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connection
IBP / Temp Port One combined connector — supports invasive pressure transducer OR temperature probe; pressure and temperature cannot be used simultaneously on this port
Host Monitor Compatibility IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)
Data Storage Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

SKU: philips-intellivue-m3001a-a02c06 Categories: , Brand:
Send In Philips IntelliVue M3001A Multi-Measurement Module | Option A02C06, Nellcor OxiMax SpO2, IBP & Temp for Repair

Philips IntelliVue M3001A — Specifications (Option A02C06)


Manufacturer Philips Healthcare
Model IntelliVue Multi-Measurement Module (MMS)
Part Number / Catalog Number M3001A
Option Covered by This Listing A02C06 — Nellcor OxiMax-compatible SpO2, ECG/Respiration, NBP, plus one combined Invasive Pressure/Temperature channel
Device Classification Multi-parameter Multi-Measurement Module (MMS) for use with IntelliVue host patient monitors
Intended Use Acquisition and transmission of physiological measurement data — ECG, arrhythmia, ST, respiration, SpO2, NBP, and invasive pressure or temperature — to a compatible IntelliVue host patient monitor. The MMS stores patient demographics, trends, and settings and supports seamless patient data transfer between compatible host monitors.
Parameters — Option A02C06 Full Package ECG (3-lead and 5-lead), Arrhythmia, ST Segment, Respiration (impedance), Nellcor OxiMax-compatible SpO2 / Pleth, Pulse Rate, NBP (oscillometric), Invasive Pressure OR Temperature (shared port)
ECG Leads 3-lead and 5-lead monitoring configurations; a 10-electrode lead set can be connected but only standard 5 electrodes (RA, LA, RL, LL, V) are used for monitoring in Option A02C06
12-Lead ECG Not included in Option A02C06. Available with Option A02C18 (12-lead ECG + invasive pressure/temperature)
Arrhythmia Detection Yes — full arrhythmia monitoring and alarm capability via host monitor
ST Segment Analysis Yes — ST monitoring with alarms via host monitor display
NIBP Method Oscillometric; adult, pediatric, and neonatal modes with manual, auto, and stat measurement options
SpO2 Technology Nellcor OxiMax-compatible SpO2 (Option A02) — for direct use with Nellcor OxiMax sensors; requires OxiMax-specific adapter cable (M1943NL) for connection
Invasive Pressure / Temperature — C06 Channel One combined connector (red/brown) supports either an invasive pressure transducer or a temperature probe. Invasive pressure and temperature cannot be used simultaneously on this port. To monitor both simultaneously, an MMS extension (M3012A or M3015A) is required.
Trend Storage Up to 8 hours of trend data at 1-minute resolution for all numeric parameters, stored within the MMS itself
Data Retention While Disconnected Patient demographics, trends, and active parameter settings retained in the MMS for up to 6 hours while disconnected from a host monitor
Connection to Host Monitor Direct cable-free attachment to rear of compatible IntelliVue host monitor, or via MSL (Measurement Link) cable for remote placement in patient vicinity
Host Monitor Compatibility Philips IntelliVue MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90; MX-series monitors; M3046A (M/M4 series, Release E and later)
Optional MMS Extensions M3015A (sidestream CO2 + additional press/temp); M3016A (mainstream CO2); M3012A (additional invasive pressure/temperature/CO2) — extensions add measurement channels without replacing the C06 connector
Power Source Powered by host monitor via MSL connection; no independent battery or AC power supply
Preventive Maintenance NBP calibration test required once every two years per OEM service documentation
Regulatory FDA 510(k) cleared; product code MHX (Class II); CE marked

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips or Nellcor.

Overview

The Philips IntelliVue M3001A (Option A02C06) is the extended-measurement configuration of the IntelliVue Multi-Measurement Module for facilities using Nellcor OxiMax sensors. The C06 designation adds a combined invasive pressure and temperature channel to the A02 standard package, making the A02C06 capable of acquiring ECG with arrhythmia and ST monitoring, impedance respiration, Nellcor OxiMax-compatible SpO2, oscillometric NBP, and either invasive arterial pressure or core temperature — all within a single plug-and-play module that docks directly to any compatible IntelliVue host monitor. The A02C06 is the direct Nellcor OxiMax equivalent of the A01C06: clinically identical in every respect except that the SpO2 interface is built around a dedicated OxiMax-compatible circuit rather than the Philips FAST SpO2 technology, and OxiMax sensors connect through the M1943NL adapter cable rather than directly to the module’s SpO2 port. This configuration is widely deployed in ICU, cardiovascular step-down, post-anesthesia care, and critical care transport environments where arterial line monitoring or core temperature tracking is standard practice alongside a Nellcor OxiMax sensor infrastructure. Patient demographics, up to eight hours of trend data at one-minute resolution, and active measurement settings are stored in the module itself and travel with the patient during transfers between IntelliVue host monitors.


The C06 Channel — Invasive Pressure or Temperature

The defining clinical addition in the A02C06 is the C06 measurement channel: a single combined connector on the module that accepts either an invasive pressure transducer (colored red) or a temperature probe (colored brown). This connector enables the module to deliver arterial line pressure waveforms and numerics — including systolic, diastolic, and mean — or continuous temperature monitoring, depending on which transducer or probe is connected at a given time. A critical operational detail confirmed in Philips OEM service documentation is that invasive pressure and temperature cannot be used simultaneously through this single connector. If a clinical situation requires both measurements to be active at the same time, an MMS extension module — such as the M3012A or M3015A — must be added to provide the additional channel. This constraint is specific to the C06 single-port design and applies equally to the A01C06, A02C06, A03C06, and A04C06 configurations. For the large majority of acute care and transport situations where only one hemodynamic or thermal parameter is active at a given time, the A02C06 meets the clinical need without supplemental hardware. The invasive pressure channel supports zeroing via a dedicated button on the module and is compatible with standard Philips-approved invasive pressure transducer kits.


Nellcor OxiMax SpO2 in the C06 Configuration

The A02C06 uses the same Nellcor OxiMax-compatible SpO2 interface found in the A02 standard module, providing SpO2 saturation, pulse rate, and a real-time plethysmogram waveform using the OxiMax sensor platform. OxiMax sensors connect to the module’s SpO2 port via the M1943NL adapter cable, which bridges the module’s 8-pin D-Connect to the OxiMax connector standard. The OxiMax platform — now maintained by Medtronic — supports a broad catalog of adult, pediatric, and neonatal sensors for finger, forehead, ear, and multisite applications, each carrying an embedded identification chip that communicates sensor type and calibration data to the monitor. The addition of the C06 pressure/temperature channel does not affect the SpO2 interface or sensor compatibility in any way — facilities already running OxiMax sensors on A02 standard modules will find the A02C06 uses identical sensors and the same M1943NL adapter cable, with the C06 connector as an additional hardware feature on the module’s connector panel.


ECG, Arrhythmia, ST, and Respiration

ECG monitoring in the M3001A A02C06 supports 3-lead and 5-lead configurations using the connected ECG trunk cable and leadset. Arrhythmia analysis delivers alarm notification for lethal and non-lethal rhythm events through the host IntelliVue monitor’s alarm infrastructure, with configurable limits and lead selection. ST segment monitoring provides continuous analysis across the monitored leads with threshold-based alarms and on-screen visualization on the host display. Respiration rate is derived from thoracic impedance using the ECG electrodes already in place, adding a continuous respiratory waveform and rate numeric without any additional patient connections. All alarm processing and display are managed by the host IntelliVue monitor once the M3001A is docked or connected via MSL cable. The A02C06 configuration is particularly suited to high-acuity environments where a complete vital signs picture — cardiac rhythm, oxygenation, blood pressure, and at least one hemodynamic line — is required at the bedside, and where the clinical team is standardized on Nellcor OxiMax sensors.


NBP Measurement and Trend Storage

Non-invasive blood pressure measurement in the A02C06 uses the oscillometric method with adult, pediatric, and neonatal measurement modes available through the host IntelliVue monitor’s interface. Manual, automatic, and stat NBP modes are supported, with each result automatically entered into the module’s trend record alongside SpO2, ECG, respiration, and pressure or temperature values. The module stores up to eight hours of numeric trend data at one-minute resolution for all active parameters within the module itself rather than on the host monitor. When the A02C06 docks to a new IntelliVue host, this complete record uploads automatically without manual re-entry. Invasive pressure calibration and zeroing settings are also preserved in the module, meaning the clinical team does not need to reconfigure the pressure channel when the patient is reconnected at a new bedside monitor. The module retains the full patient record — including demographics, trends, and active measurement settings — for up to six hours while disconnected from any host. The NBP pneumatic assembly requires a performance calibration check once every two years per OEM service documentation.


MMS Extensions and Simultaneous Pressure and Temperature

For facilities that need simultaneous invasive pressure and temperature monitoring, the A02C06’s single shared C06 port can be supplemented with MMS extension modules. The M3012A Measurement Server Extension adds an additional pressure and temperature channel, enabling both the C06 connector on the M3001A and the extension’s channels to be used concurrently — in practice allowing one channel for invasive pressure and one for temperature at the same time. The M3015A extension adds sidestream CO2 capnography and an additional pressure/temperature channel. The M3016A adds mainstream CO2. These extensions attach physically to the M3001A and inherit power and network connectivity from the host monitor through the module without requiring separate power supplies or additional MSL cables. Facilities that routinely need simultaneous pressure and temperature may also wish to consider the A02C18 configuration, which provides a different connector arrangement supporting more concurrent measurements in a single module without an extension.


Host Monitor Connectivity and System Integration

The M3001A A02C06 connects to compatible IntelliVue host monitors in either the direct-dock configuration — locking to the rear of the host monitor without cables — or the remote configuration via MSL cable. Once connected, all monitoring, alarm, and configuration functions are managed through the host monitor’s interface. The A02C06 is compatible with the full IntelliVue MP-series platform (MP20 through MP90), the MX-series monitors, and the M3046A (M/M4 series) running Release E or higher software. When the host monitor is networked to the IntelliVue Information Center, all measurement data from the A02C06 — including invasive pressure waveforms and temperature — flows transparently for central monitoring, trend archiving, and clinical reporting alongside all other networked patient data.


IPR Medical — Buy, Sell, Repair, and Parts

IPR Medical is a secondary market specialist for Philips IntelliVue patient monitoring equipment, including the M3001A across all option configurations. For the M3001A A02C06, IPR Medical purchases units in various conditions, sells tested and refurbished modules, and provides repair services for component-level issues including the NBP pneumatic assembly, Nellcor OxiMax SpO2 interface circuitry, invasive pressure and temperature interface, ECG acquisition hardware, and MSL connectivity. IPR Medical also stocks commonly requested accessories for the A02C06, including ECG trunk cables and leadsets, the M1943NL OxiMax adapter cable, Nellcor OxiMax sensors, NIBP cuffs and hoses, invasive pressure transducer kits, temperature probes, and MSL cables. Contact our team to confirm current availability, discuss configuration requirements, or request a service assessment.

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips or Nellcor.

Weight 1 lbs
Dimensions 8 × 6 × 4 in
Output Options

A01 – Fast SPO2, NIBP, ECG/RESP, A01C06 – Fast SPO2, NIBP, ECG/RESP, IBP, A01C12 – Fast SPO2, NIBP, 12 ECG/RESP, A01C18 – Fast SPO2, NIBP, 12 ECG/RESP, IBP, A2 – Nellcor Oximax SPO2, NIBP, ECG/RESP, A02C06 – Nellcor Oximax SPO2, NIBP, ECG/RESP, IBP, A02C12 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, A02C18 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, IBP, A03 – Masimo SET SPO2, NIBP, ECG/RESP, A03C06 – Masimo SET SPO2, NIBP, ECG/RESP, IBP, A03C12 – Masimo SET SPO2, NIBP, 12 ECG/RESP, A03C18 – Masimo SET SPO2, NIBP, 12 ECG/RESP, IBP, A04 – Nellcor Oximax SPO2, NIBP, ECG/RESP, A04C06 – Nellcor Oximax SPO2, NIBP, ECG/RESP, IBP, A04C12 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, A04C18 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, IBP

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the Philips IntelliVue M3001A (Option A02C06). The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.


MMS Extension Modules

M3012A Hemodynamic/Pressure/Temperature MMS Extension — adds an additional invasive pressure channel and temperature channel, enabling simultaneous use of pressure and temperature when combined with the A02C06’s shared C06 port
M3015A Sidestream CO2 Measurement Server Extension — attaches to the M3001A to add sidestream capnography plus an additional pressure/temperature channel; powered via host monitor MSL connection
M3016A Mainstream CO2 Measurement Server Extension — attaches to the M3001A to add mainstream capnography; powered via host monitor MSL connection

ECG Cables and Leadsets

M1668A 5-lead ECG trunk cable (12-pin connector) — compatible with M3001A; also accepts 3-lead sets
M1669A 3-lead ECG trunk cable — compatible with M3001A for 3-lead monitoring configurations
M1977A 5-lead ECG set, direct-connect pinch/grabber leadwires — for use with M3001A compatible trunk cables (AAMI color coding)
3-lead direct-connect leadwires 3-lead snap and pinch/grabber leadwire sets compatible with M3001A trunk cables — contact IPR Medical to confirm specific part numbers available

SpO2 Adapter Cable (Required for OxiMax Sensors)

M1943NL Philips SpO2 adapter cable — 8-pin D-Connect to OxiMax interface; required to connect Nellcor OxiMax sensors to the M3001A Option A02C06 SpO2 port

Nellcor OxiMax SpO2 Sensors

M4789A / M4789B Nellcor OxiMax SpO2 finger probe sensors — adult; for use with M3001A Option A02C06 via M1943NL adapter cable
P3119A Nellcor Covidien OxiMax adult finger probe sensor — compatible with M3001A Option A02C06 via M1943NL adapter
D-YS Nellcor Covidien OxiMax adult ear clip sensor — compatible with M3001A Option A02C06 via M1943NL adapter
Nellcor DB9 MultiSite sensor Nellcor OxiMax multisite sensor — compatible with M3001A Option A02C06 via M1943NL adapter; contact IPR Medical to confirm current part number and availability

Invasive Pressure Accessories

IBP adapter cables Invasive pressure adapter cables connecting the M3001A C06 port (12-pin connector) to standard pressure transducer brands including BD and Utah connector styles — contact IPR Medical to confirm specific part numbers and transducer compatibility
Disposable pressure transducer kits Single-use invasive pressure transducer kits compatible with the M3001A C06 channel — contact IPR Medical to confirm compatible transducer brands and part numbers for your facility’s protocol

Temperature Probes

Temperature probes (C06 port) Reusable and single-use temperature probes compatible with the M3001A C06 temperature connector — rectal, esophageal, skin, and nasopharyngeal probe types available; contact IPR Medical to confirm specific part numbers and probe type availability

NIBP Cuffs and Hoses

M1599B Philips NIBP single hose, male-to-female metal connector — replacement NBP hose compatible with M3001A
M3918A Philips NIBP single hose — replacement NBP hose compatible with M3001A
Adult NIBP cuffs Single-patient and reusable adult NBP cuffs compatible with the M3001A NBP hose connection — contact IPR Medical to confirm sizing and part number availability
Pediatric / neonatal NIBP cuffs Pediatric and neonatal cuff sizes compatible with the M3001A — contact IPR Medical to confirm current availability

Cables and Connectivity

MSL cable Measurement Link cable — connects the M3001A to the host IntelliVue monitor when the module is not directly docked; carries power, data, and network communication

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Reviews