Philips IntelliVue M3001A Multi-Measurement Module | Option A03C06, Masimo SET SpO2, IBP & Temp
The Philips IntelliVue M3001A (Option A03C06) is the extended-measurement configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. Building on the A03 standard package — ECG, arrhythmia, ST, respiration, Masimo SET SpO2, and oscillometric NBP — the C06 option adds a combined invasive pressure and temperature connector, enabling the module to support either invasive blood pressure monitoring or temperature measurement in addition to the full core parameter set. The A03C06 is the Masimo SET equivalent of the A01C06 and A02C06, delivering an identical clinical measurement footprint while using a dedicated Masimo SET SpO2 interface and requiring the Masimo LNC MP-10 dual-key patient cable for sensor connection. This configuration is widely deployed in ICU, cardiovascular step-down, post-anesthesia care, and critical care transport environments where arterial line monitoring or core temperature tracking is standard practice alongside a Masimo LNCS sensor fleet. As with all M3001A variants, patient demographics, trend data, and measurement settings are stored in the module itself and travel with the patient between IntelliVue host monitors.
| Part Number / Option | M3001A, Option A03C06 |
| Parameters Monitored | ECG (3/5-lead), Arrhythmia, ST, Respiration, Masimo SET SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous) |
| SpO2 Technology | Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection |
| IBP / Temp Port | One combined connector — supports invasive pressure transducer OR temperature probe; pressure and temperature cannot be used simultaneously on this port |
| Host Monitor Compatibility | IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4) |
| Data Storage | Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected |
IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
Philips IntelliVue M3001A — Specifications (Option A03C06)
| Manufacturer | Philips Healthcare |
| Model | IntelliVue Multi-Measurement Module (MMS) |
| Part Number / Catalog Number | M3001A |
| Option Covered by This Listing | A03C06 — Masimo SET SpO2, ECG/Respiration, NBP, plus one combined Invasive Pressure/Temperature channel |
| Device Classification | Multi-parameter Multi-Measurement Module (MMS) for use with IntelliVue host patient monitors |
| Intended Use | Acquisition and transmission of physiological measurement data — ECG, arrhythmia, ST, respiration, SpO2, NBP, and invasive pressure or temperature — to a compatible IntelliVue host patient monitor. The MMS stores patient demographics, trends, and settings and supports seamless patient data transfer between compatible host monitors. |
| Parameters — Option A03C06 Full Package | ECG (3-lead and 5-lead), Arrhythmia, ST Segment, Respiration (impedance), Masimo SET SpO2 / Pleth, Pulse Rate, NBP (oscillometric), Invasive Pressure OR Temperature (shared port) |
| ECG Leads | 3-lead and 5-lead monitoring configurations; a 10-electrode lead set can be connected but only standard 5 electrodes (RA, LA, RL, LL, V) are used for monitoring in Option A03C06 |
| 12-Lead ECG | Not included in Option A03C06. Available with Option A03C18 (12-lead ECG + invasive pressure/temperature) |
| Arrhythmia Detection | Yes — full arrhythmia monitoring and alarm capability via host monitor |
| ST Segment Analysis | Yes — ST monitoring with alarms via host monitor display |
| NIBP Method | Oscillometric; adult, pediatric, and neonatal modes with manual, auto, and stat measurement options |
| SpO2 Technology | Masimo SET SpO2 (Option A03) — for use with Masimo LNCS sensors; connection requires the Masimo LNC MP-10 dual-key patient cable (Masimo part 2281) |
| Invasive Pressure / Temperature — C06 Channel | One combined connector (red/brown) supports either an invasive pressure transducer or a temperature probe. Invasive pressure and temperature cannot be used simultaneously on this port. To monitor both simultaneously, an MMS extension (M3012A or M3015A) is required. |
| Trend Storage | Up to 8 hours of trend data at 1-minute resolution for all numeric parameters, stored within the MMS itself |
| Data Retention While Disconnected | Patient demographics, trends, and active parameter settings retained in the MMS for up to 6 hours while disconnected from a host monitor |
| Connection to Host Monitor | Direct cable-free attachment to rear of compatible IntelliVue host monitor, or via MSL (Measurement Link) cable for remote placement in patient vicinity |
| Host Monitor Compatibility | Philips IntelliVue MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90; MX-series monitors; M3046A (M/M4 series, Release E and later) |
| Optional MMS Extensions | M3015A (sidestream CO2 + additional press/temp); M3016A (mainstream CO2); M3012A (additional invasive pressure/temperature/CO2) — extensions add measurement channels without replacing the C06 connector |
| Power Source | Powered by host monitor via MSL connection; no independent battery or AC power supply |
| Preventive Maintenance | NBP calibration test required once every two years per OEM service documentation |
| Regulatory | FDA 510(k) cleared; product code MHX (Class II); CE marked |
IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Trademark Notice: Philips, Masimo, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips, Masimo, or Nellcor.
Overview
The Philips IntelliVue M3001A (Option A03C06) is the extended-measurement configuration of the IntelliVue Multi-Measurement Module for facilities using Masimo LNCS sensors. The C06 designation adds a combined invasive pressure and temperature channel to the A03 standard package, making the A03C06 capable of acquiring ECG with arrhythmia and ST monitoring, impedance respiration, Masimo SET SpO2, oscillometric NBP, and either invasive arterial pressure or core temperature — all within a single plug-and-play module that docks directly to any compatible IntelliVue host monitor. The A03C06 is the direct Masimo SET equivalent of the A01C06 and A02C06: clinically identical in every respect except that the SpO2 interface is built around a dedicated Masimo SET circuit, and Masimo LNCS sensors connect via the Masimo LNC MP-10 dual-key patient cable rather than directly or through an OxiMax adapter. This configuration is widely deployed in ICU, cardiovascular step-down, post-anesthesia care, and critical care transport environments where arterial line monitoring or core temperature tracking is standard practice alongside a Masimo LNCS sensor infrastructure. Patient demographics, up to eight hours of trend data at one-minute resolution, and active measurement settings are stored in the module itself and travel with the patient during transfers between IntelliVue host monitors.
The C06 Channel — Invasive Pressure or Temperature
The defining clinical addition in the A03C06 is the C06 measurement channel: a single combined connector on the module that accepts either an invasive pressure transducer (colored red) or a temperature probe (colored brown). This connector enables the module to deliver arterial line pressure waveforms and numerics — including systolic, diastolic, and mean — or continuous temperature monitoring, depending on which transducer or probe is connected at a given time. A critical operational detail confirmed in Philips OEM service documentation is that invasive pressure and temperature cannot be used simultaneously through this single connector. If a clinical situation requires both measurements to be active at the same time, an MMS extension module — such as the M3012A or M3015A — must be added to provide the additional channel. This constraint is specific to the C06 single-port design and applies equally across all A-option C06 configurations. For the large majority of acute care and transport situations where only one hemodynamic or thermal parameter is active at a given time, the A03C06 meets the clinical need without supplemental hardware. The invasive pressure channel supports zeroing via a dedicated button on the module and is compatible with standard Philips-approved invasive pressure transducer kits.
Masimo SET SpO2 in the C06 Configuration
The A03C06 uses the same Masimo SET SpO2 interface found in the A03 standard module, providing SpO2 saturation, pulse rate, and a real-time plethysmogram waveform using the Masimo SET signal extraction technology. Masimo SET is specifically designed to reduce erroneous readings and false alarms under conditions of patient motion and low perfusion, making it particularly well suited to hemodynamically unstable patients — exactly the population likely to be monitored via an arterial line using the C06 pressure channel. Masimo LNCS sensors connect to the module’s SpO2 port via the Masimo LNC MP-10 dual-key patient cable (Masimo part 2281), confirmed in Philips’ own product documentation as the appropriate connection method for IntelliVue Masimo SET modules and Multi-Measurement Servers. The dual-key design prevents incorrect cable orientation in fast-paced clinical environments. The addition of the C06 pressure/temperature channel does not affect the Masimo SET interface or sensor compatibility in any way — facilities already running Masimo LNCS sensors on A03 standard modules will find the A03C06 uses identical sensors and the same LNC MP-10 cable, with the C06 connector as an additional hardware feature on the module’s connector panel.
ECG, Arrhythmia, ST, and Respiration
ECG monitoring in the M3001A A03C06 supports 3-lead and 5-lead configurations using the connected ECG trunk cable and leadset. Arrhythmia analysis delivers alarm notification for lethal and non-lethal rhythm events through the host IntelliVue monitor’s alarm infrastructure, with configurable limits and lead selection. ST segment monitoring provides continuous analysis across the monitored leads with threshold-based alarms and on-screen visualization on the host display. Respiration rate is derived from thoracic impedance using the ECG electrodes already in place, adding a continuous respiratory waveform and rate numeric without any additional patient connections. All alarm processing and display are managed by the host IntelliVue monitor once the M3001A is docked or connected via MSL cable. The A03C06 is particularly suited to high-acuity environments where a complete vital signs picture — cardiac rhythm, oxygenation, blood pressure, and at least one hemodynamic line or temperature measurement — is required at the bedside alongside a Masimo LNCS sensor infrastructure.
NBP Measurement and Trend Storage
Non-invasive blood pressure measurement in the A03C06 uses the oscillometric method with adult, pediatric, and neonatal measurement modes available through the host IntelliVue monitor’s interface. Manual, automatic, and stat NBP modes are supported, with each result automatically entered into the module’s trend record alongside SpO2, ECG, respiration, and pressure or temperature values. The module stores up to eight hours of numeric trend data at one-minute resolution for all active parameters within the module itself rather than on the host monitor. When the A03C06 docks to a new IntelliVue host, this complete record uploads automatically without manual re-entry. Invasive pressure calibration and zeroing settings are also preserved in the module, meaning the clinical team does not need to reconfigure the pressure channel when the patient is reconnected at a new bedside monitor. The module retains the full patient record — including demographics, trends, and active measurement settings — for up to six hours while disconnected from any host. The NBP pneumatic assembly requires a performance calibration check once every two years per OEM service documentation.
MMS Extensions and Simultaneous Pressure and Temperature
For facilities that need simultaneous invasive pressure and temperature monitoring, the A03C06’s single shared C06 port can be supplemented with MMS extension modules. The M3012A Measurement Server Extension adds an additional pressure and temperature channel, enabling both the C06 connector on the M3001A and the extension’s channels to be used concurrently — in practice allowing one channel for invasive pressure and one for temperature at the same time. The M3015A extension adds sidestream CO2 capnography and an additional pressure/temperature channel. The M3016A adds mainstream CO2. These extensions attach physically to the M3001A and inherit power and network connectivity from the host monitor through the module without requiring separate power supplies or additional MSL cables. Facilities that routinely need simultaneous pressure and temperature may also wish to consider the A03C18 configuration, which provides a different connector arrangement supporting more concurrent measurements in a single module without an extension.
Host Monitor Connectivity and System Integration
The M3001A A03C06 connects to compatible IntelliVue host monitors in either the direct-dock configuration — locking to the rear of the host monitor without cables — or the remote configuration via MSL cable. Once connected, all monitoring, alarm, and configuration functions are managed through the host monitor’s interface. The A03C06 is compatible with the full IntelliVue MP-series platform (MP20 through MP90), the MX-series monitors, and the M3046A (M/M4 series) running Release E or higher software. When the host monitor is networked to the IntelliVue Information Center, all measurement data from the A03C06 — including invasive pressure waveforms and temperature — flows transparently for central monitoring, trend archiving, and clinical reporting alongside all other networked patient data.
IPR Medical — Buy, Sell, Repair, and Parts
IPR Medical is a secondary market specialist for Philips IntelliVue patient monitoring equipment, including the M3001A across all option configurations. For the M3001A A03C06, IPR Medical purchases units in various conditions, sells tested and refurbished modules, and provides repair services for component-level issues including the NBP pneumatic assembly, Masimo SET SpO2 interface circuitry, invasive pressure and temperature interface, ECG acquisition hardware, and MSL connectivity. IPR Medical also stocks commonly requested accessories for the A03C06, including ECG trunk cables and leadsets, the Masimo LNC MP-10 patient cable, Masimo LNCS sensors, NIBP cuffs and hoses, invasive pressure transducer kits, temperature probes, and MSL cables. Contact our team to confirm current availability, discuss configuration requirements, or request a service assessment.
IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Trademark Notice: Philips, Masimo, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips, Masimo, or Nellcor.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 6 × 4 in |
| Output Options | A01 – Fast SPO2, NIBP, ECG/RESP, A01C06 – Fast SPO2, NIBP, ECG/RESP, IBP, A01C12 – Fast SPO2, NIBP, 12 ECG/RESP, A01C18 – Fast SPO2, NIBP, 12 ECG/RESP, IBP, A2 – Nellcor Oximax SPO2, NIBP, ECG/RESP, A02C06 – Nellcor Oximax SPO2, NIBP, ECG/RESP, IBP, A02C12 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, A02C18 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, IBP, A03 – Masimo SET SPO2, NIBP, ECG/RESP, A03C06 – Masimo SET SPO2, NIBP, ECG/RESP, IBP, A03C12 – Masimo SET SPO2, NIBP, 12 ECG/RESP, A03C18 – Masimo SET SPO2, NIBP, 12 ECG/RESP, IBP, A04 – Nellcor Oximax SPO2, NIBP, ECG/RESP, A04C06 – Nellcor Oximax SPO2, NIBP, ECG/RESP, IBP, A04C12 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, A04C18 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, IBP |
Compatible Parts and Accessories
IPR Medical stocks a range of compatible parts and accessories for the Philips IntelliVue M3001A (Option A03C06). The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.
MMS Extension Modules
| M3012A | Hemodynamic/Pressure/Temperature MMS Extension — adds an additional invasive pressure channel and temperature channel, enabling simultaneous use of pressure and temperature when combined with the A03C06’s shared C06 port |
| M3015A | Sidestream CO2 Measurement Server Extension — attaches to the M3001A to add sidestream capnography plus an additional pressure/temperature channel; powered via host monitor MSL connection |
| M3016A | Mainstream CO2 Measurement Server Extension — attaches to the M3001A to add mainstream capnography; powered via host monitor MSL connection |
ECG Cables and Leadsets
| M1668A | 5-lead ECG trunk cable (12-pin connector) — compatible with M3001A; also accepts 3-lead sets |
| M1669A | 3-lead ECG trunk cable — compatible with M3001A for 3-lead monitoring configurations |
| M1977A | 5-lead ECG set, direct-connect pinch/grabber leadwires — for use with M3001A compatible trunk cables (AAMI color coding) |
| 3-lead direct-connect leadwires | 3-lead snap and pinch/grabber leadwire sets compatible with M3001A trunk cables — contact IPR Medical to confirm specific part numbers available |
SpO2 Patient Cable (Required for Masimo LNCS Sensors)
| Masimo LNC MP-10 (part 2281) | Masimo LNCS dual-key patient cable for IntelliVue Masimo SET module and MMS — required to connect Masimo LNCS sensors to the M3001A Option A03C06 SpO2 port; confirmed compatible in Philips product documentation for this cable |
| Masimo LNCS-4-EXT (part 2021) | Masimo LNCS extension cable, 4 ft — extends reach between Masimo LNCS sensor and LNC MP-10 patient cable at the M3001A A03C06 SpO2 port |
Masimo LNCS SpO2 Sensors
| Masimo 1863 (LNCS DC-I) | Masimo LNCS adult reusable SpO2 sensor, 3 ft — for use with M3001A Option A03C06 via LNC MP-10 patient cable |
| Masimo 1864 (LNCS DC-IP) | Masimo LNCS pediatric reusable SpO2 sensor, 3 ft — for use with M3001A Option A03C06 via LNC MP-10 patient cable |
| Masimo 2653 (LNCS DBI) | Masimo LNCS neonatal/infant reusable SpO2 sensor — for use with M3001A Option A03C06 via LNC MP-10 patient cable |
| Masimo LNCS disposable sensors | Adult, pediatric, neonatal, and multisite disposable LNCS sensors compatible with M3001A Option A03C06 via LNC MP-10 cable — contact IPR Medical to confirm specific sensor availability |
Invasive Pressure Accessories
| IBP adapter cables | Invasive pressure adapter cables connecting the M3001A C06 port (12-pin connector) to standard pressure transducer brands including BD and Utah connector styles — contact IPR Medical to confirm specific part numbers and transducer compatibility |
| Disposable pressure transducer kits | Single-use invasive pressure transducer kits compatible with the M3001A C06 channel — contact IPR Medical to confirm compatible transducer brands and part numbers for your facility’s protocol |
Temperature Probes
| Temperature probes (C06 port) | Reusable and single-use temperature probes compatible with the M3001A C06 temperature connector — rectal, esophageal, skin, and nasopharyngeal probe types available; contact IPR Medical to confirm specific part numbers and probe type availability |
NIBP Cuffs and Hoses
| M1599B | Philips NIBP single hose, male-to-female metal connector — replacement NBP hose compatible with M3001A |
| M3918A | Philips NIBP single hose — replacement NBP hose compatible with M3001A |
| Adult NIBP cuffs | Single-patient and reusable adult NBP cuffs compatible with the M3001A NBP hose connection — contact IPR Medical to confirm sizing and part number availability |
| Pediatric / neonatal NIBP cuffs | Pediatric and neonatal cuff sizes compatible with the M3001A — contact IPR Medical to confirm current availability |
Cables and Connectivity
| MSL cable | Measurement Link cable — connects the M3001A to the host IntelliVue monitor when the module is not directly docked; carries power, data, and network communication |
IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.