IPR Medical

Recertified

Philips IntelliVue M3001A Multi-Measurement Module | Option A03C12, 12-Lead ECG & Masimo SET SpO2

$1,595.00 Original price was: $1,595.00.$1,395.00Current price is: $1,395.00.

The Philips IntelliVue M3001A (Option A03C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. Building on the A03 standard package — ECG, arrhythmia, ST, respiration, Masimo SET SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG using only 5 electrodes. The A03C12 is the Masimo SET equivalent of the A01C12 and A02C12: clinically identical in 12-lead ECG capability and overall parameter set, with the SpO2 interface built around a dedicated Masimo SET circuit, and Masimo LNCS sensors connecting via the Masimo LNC MP-10 dual-key patient cable (part 2281). It is the correct choice for facilities that require documented, diagnostic-quality 12-lead ECG recordings alongside continuous monitoring and are standardized on Masimo LNCS sensors, but do not need invasive pressure or temperature within the MMS module itself.

Part Number / Option M3001A, Option A03C12
Parameters Monitored ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Masimo SET SpO2, NBP (oscillometric)
SpO2 Technology Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection
12-Lead ECG Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported
Invasive Pressure / Temperature Not included in Option A03C12 — available with Option A03C18
Host Monitor Compatibility IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)
Data Storage Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

SKU: philips-intellivue-m3001a-a03c12 Categories: , Brand:
Send In Philips IntelliVue M3001A Multi-Measurement Module | Option A03C12, 12-Lead ECG & Masimo SET SpO2 for Repair

Philips IntelliVue M3001A — Specifications (Option A03C12)


Manufacturer Philips Healthcare
Model IntelliVue Multi-Measurement Module (MMS)
Part Number / Catalog Number M3001A
Option Covered by This Listing A03C12 — Masimo SET SpO2, 3/5/12-lead ECG, NBP (no invasive pressure or temperature)
Device Classification Multi-parameter Multi-Measurement Module (MMS) for use with IntelliVue host patient monitors
Intended Use Acquisition and transmission of physiological measurement data — including 12-lead ECG, arrhythmia, ST, respiration, SpO2, and NBP — to a compatible IntelliVue host patient monitor. The MMS stores patient demographics, trends, and settings and supports seamless patient data transfer between compatible host monitors.
Parameters — Option A03C12 Full Package ECG (3-lead, 5-lead, and 12-lead), EASI ECG, Arrhythmia, ST Segment (up to 12-lead analysis), QT/QTc, Respiration (impedance), Masimo SET SpO2 / Pleth, Pulse Rate, NBP (oscillometric)
ECG Leads 3-lead, 5-lead, and conventional 12-lead (10-electrode lead set) monitoring; any number of electrodes between 3 and 10 can be used for ECG monitoring using conventional lead placements
12-Lead ECG Capability Conventional 12-lead ECG capture providing diagnostic signal quality as defined in the ANSI/AAMI EC11-1991 standard when used with IntelliVue host monitors; ECG data can be transmitted to and stored in compatible ECG management systems via the IntelliVue Information Center iX
EASI ECG Yes — EASI lead placement provides derived 12-lead ECG data using only 5 electrodes; reduces setup time, minimizes interference with clinical procedures, and increases patient comfort
Arrhythmia Detection Yes — full arrhythmia monitoring and alarm capability via host monitor
ST Segment Analysis Yes — up to 12-lead ST segment monitoring with alarms at the bedside; ST Map visualization available via host monitor display
QT/QTc Monitoring Yes — measured QT interval, heart-rate corrected QTc value, and QTc variation tracking relative to a stored baseline
NIBP Method Oscillometric; adult, pediatric, and neonatal modes with manual, auto, and stat measurement options
SpO2 Technology Masimo SET SpO2 (Option A03) — for use with Masimo LNCS sensors; connection requires the Masimo LNC MP-10 dual-key patient cable (Masimo part 2281)
Invasive Pressure / Temperature Not included in Option A03C12. To add invasive pressure and temperature to a Masimo SET 12-lead ECG configuration, source Option A03C18. MMS extensions (M3012A, M3015A) can also add pressure/temperature capability.
Trend Storage Up to 8 hours of trend data at 1-minute resolution for all numeric parameters, stored within the MMS itself
Data Retention While Disconnected Patient demographics, trends, and active parameter settings retained in the MMS for up to 6 hours while disconnected from a host monitor
Connection to Host Monitor Direct cable-free attachment to rear of compatible IntelliVue host monitor, or via MSL (Measurement Link) cable for remote placement in patient vicinity
Host Monitor Compatibility Philips IntelliVue MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90; MX-series monitors; M3046A (M/M4 series, Release E and later)
Optional MMS Extensions M3015A (sidestream CO2 + press/temp channel); M3016A (mainstream CO2); M3012A (invasive pressure/temperature/CO2) — extensions can add pressure and temperature capability to the A03C12 without changing the module
Power Source Powered by host monitor via MSL connection; no independent battery or AC power supply
Preventive Maintenance NBP calibration test required once every two years per OEM service documentation
Regulatory FDA 510(k) cleared; product code MHX (Class II); CE marked

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips or Masimo.

Overview

The Philips IntelliVue M3001A (Option A03C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities using Masimo LNCS sensors. The C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG to the A03 standard parameter set — ECG, arrhythmia, ST, respiration, Masimo SET SpO2, and oscillometric NBP — without adding invasive pressure or temperature. The A03C12 is the direct Masimo SET equivalent of the A01C12 and A02C12: clinically identical in 12-lead ECG capability and overall parameter set, with the SpO2 interface built around the Masimo SET circuit and Masimo LNCS sensors connecting via the LNC MP-10 dual-key patient cable (Masimo part 2281). For facilities standardized on Masimo LNCS sensors that require documented, diagnostic-quality 12-lead ECG alongside continuous monitoring but do not need hemodynamic line monitoring within the MMS module, the A03C12 is the precise configuration. As with all M3001A variants, patient demographics, up to eight hours of trend data at one-minute resolution, and active measurement settings are stored in the module and travel with the patient between compatible IntelliVue host monitors.


12-Lead ECG — Conventional Capture and EASI

The C12 option provides two distinct paths to 12-lead ECG data within the same module. Conventional 12-lead ECG uses a 10-electrode lead set connected to a compatible 10-lead trunk cable, delivering diagnostic signal quality as defined in the ANSI/AAMI EC11-1991 standard when used with a compatible IntelliVue host monitor — the quality required for formal clinical ECG interpretation and documentation. Any number of electrodes between 3 and 10 can be used for ongoing ECG monitoring using conventional lead placements, allowing clinical teams to apply fewer electrodes for routine rhythm monitoring and the full 10-electrode set when a documented 12-lead capture is required. When connected to the IntelliVue Information Center iX, 12-lead ECG captures can be transmitted to and stored in a compatible ECG management system, and previously acquired ECGs can be retrieved at the bedside. EASI ECG provides a parallel path to 12-lead data using only 5 electrodes in the EASI configuration, deriving 12-lead waveforms mathematically from the 5-electrode signal. EASI reduces the number of patient connections, minimizes interference with clinical procedures, and improves patient comfort during extended monitoring — especially valuable in transport, post-operative recovery, and situations where chest access is limited. Up to 12-lead ST segment analysis with configurable alarm thresholds and QT/QTc interval monitoring are also available, extending the cardiac monitoring capability of the A03C12 beyond routine rhythm surveillance.


Masimo SET SpO2 in the C12 Configuration

The A03C12 uses the same Masimo SET SpO2 interface found in the A03 standard module, providing SpO2 saturation, pulse rate, and a real-time plethysmogram waveform using Masimo’s signal extraction technology. Masimo SET is specifically designed to maintain measurement accuracy under conditions of patient motion and low perfusion — characteristics particularly valuable in cardiac monitoring environments where arrhythmia and hemodynamic instability can cause artifact-prone conditions. Masimo LNCS sensors connect to the module’s SpO2 port via the Masimo LNC MP-10 dual-key patient cable (part 2281), confirmed in Philips product documentation as the appropriate connection method for IntelliVue Masimo SET modules and Multi-Measurement Servers. The dual-key design prevents incorrect cable orientation during rapid patient connections. The addition of 12-lead ECG capability through the C12 option does not affect the Masimo SET interface, the LNC MP-10 cable requirement, or sensor compatibility in any way. Facilities already running Masimo LNCS sensors on A03 standard modules will find the A03C12 uses identical sensors and the same LNC MP-10 cable, with 12-lead ECG as an additional capability.


A03C12 vs. A03C06 and A03C18 — Choosing the Right Configuration

The three C-option suffixes in the M3001A A03 family represent distinct additions to the A03 standard package. The C06 adds an invasive pressure/temperature channel only, with no 12-lead ECG. The C12 adds 12-lead ECG only, with no invasive pressure or temperature. The C18 combines both. For facilities evaluating which configuration suits a given care area, the decision is straightforward: if 12-lead ECG documentation is the requirement and hemodynamic monitoring is handled by a separate system, the A03C12 is the appropriate and most focused choice. For ICU and cardiovascular environments that need both 12-lead ECG and arterial line or temperature monitoring in a single Masimo SET MMS module, the A03C18 is the correct selection. If invasive pressure or temperature capability needs to be added to an existing A03C12 fleet without replacing modules, the M3012A or M3015A MMS extension can provide that channel.


NBP Measurement and Trend Storage

Non-invasive blood pressure measurement uses the oscillometric method with adult, pediatric, and neonatal modes available through the host IntelliVue monitor’s interface. Manual, automatic, and stat NBP modes are supported, with each result automatically entered into the module’s trend record alongside SpO2, ECG, and respiration values. The module stores up to eight hours of numeric trend data at one-minute resolution within itself rather than on the host monitor. When the A03C12 docks to a new IntelliVue host, this complete record uploads automatically without manual re-entry, and the 12-lead ECG capability and all lead configuration settings are immediately available without reconfiguration. The module retains the full patient record for up to six hours while disconnected, supporting clean handoffs between care areas. The NBP pneumatic assembly requires a calibration check once every two years per OEM service documentation.


Adding Pressure and Temperature to A03C12 Fleets

Facilities standardized on the A03C12 that occasionally need invasive pressure or temperature monitoring at specific beds can address that need through MMS extension modules without replacing any A03C12 units. The M3012A Measurement Server Extension attaches directly to the M3001A and provides an invasive pressure channel and a temperature channel, adding C06-equivalent hemodynamic capability to any A03C12 when the extension is connected. The M3015A extension adds sidestream CO2 capnography along with an additional pressure/temperature channel. The M3016A adds mainstream CO2. These extensions inherit power and connectivity from the host monitor through the module, requiring no separate power supplies or additional MSL cables. This approach allows a standardized A03C12 fleet to serve both pure cardiac monitoring beds and occasional hemodynamic monitoring needs through selective extension deployment, without maintaining separate A03C06 or A03C18 inventory.


Host Monitor Connectivity and System Integration

The M3001A A03C12 connects to compatible IntelliVue host monitors in either the direct-dock configuration or the remote configuration via MSL cable. Once connected, all monitoring, alarm, and configuration functions are managed through the host monitor’s interface. The A03C12 is compatible with the full IntelliVue MP-series platform (MP20 through MP90), the MX-series monitors, and the M3046A (M/M4 series) running Release E or higher software. When the host monitor is networked to the IntelliVue Information Center, all measurement data from the A03C12 — including 12-lead ECG captures — flows transparently for central monitoring, trend archiving, ECG storage and retrieval, and clinical reporting alongside all other networked patient data.


IPR Medical — Buy, Sell, Repair, and Parts

IPR Medical is a secondary market specialist for Philips IntelliVue patient monitoring equipment, including the M3001A across all option configurations. For the M3001A A03C12, IPR Medical purchases units in various conditions, sells tested and refurbished modules, and provides repair services for component-level issues including the NBP pneumatic assembly, Masimo SET SpO2 interface circuitry, ECG acquisition hardware, and MSL connectivity. IPR Medical also stocks commonly requested accessories for the A03C12, including 10-lead ECG trunk cables and leadsets for 12-lead capture, 5-lead and 6-lead cables for standard and EASI monitoring, the Masimo LNC MP-10 patient cable (part 2281), Masimo LNCS sensors, NIBP cuffs and hoses, and MSL cables. Contact our team to confirm current availability, discuss configuration requirements, or request a service assessment.

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips or Masimo.

Weight 1 lbs
Dimensions 8 × 6 × 4 in

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the Philips IntelliVue M3001A (Option A03C12). The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.


MMS Extension Modules

M3012A Hemodynamic/Pressure/Temperature MMS Extension — attaches to the M3001A A03C12 to add an invasive pressure channel and temperature channel without replacing the module
M3015A Sidestream CO2 Measurement Server Extension — attaches to the M3001A to add sidestream capnography plus an additional pressure/temperature channel; powered via host monitor MSL connection
M3016A Mainstream CO2 Measurement Server Extension — attaches to the M3001A to add mainstream capnography; powered via host monitor MSL connection

ECG Cables and Leadsets — 12-Lead

M1665A 10-lead trunk cable (12-pin connector) — for conventional 12-lead ECG capture on the M3001A A03C12; pair with one chest leadset and one limb leadset for full 10-electrode application
M1663A / M1949A Alternative 10-lead trunk cables (12-pin connector) — compatible with M3001A C12/C18 for 12-lead ECG applications; contact IPR Medical to confirm availability
Chest leadsets (AAMI) Precordial chest leadsets for use with 10-lead trunk cables on M3001A A03C12 — contact IPR Medical to confirm specific part numbers available
Limb leadsets (AAMI) Limb leadsets for use with 10-lead trunk cables on M3001A A03C12 — contact IPR Medical to confirm specific part numbers available

ECG Cables and Leadsets — 3-Lead, 5-Lead, and EASI

M1668A 5-lead ECG trunk cable (12-pin connector) — for 5-lead monitoring and EASI ECG configurations on the M3001A A03C12; also accepts 3-lead sets
M1667A 6-lead trunk cable (12-pin connector) — for 6-lead and EASI ECG monitoring on the M3001A A03C12; also accepts 3-lead and 5-lead sets
M1669A 3-lead ECG trunk cable — compatible with M3001A for 3-lead monitoring configurations
M1977A 5-lead ECG set, direct-connect pinch/grabber leadwires — for use with M3001A compatible trunk cables (AAMI color coding)
3-lead direct-connect leadwires 3-lead snap and pinch/grabber leadwire sets compatible with M3001A trunk cables — contact IPR Medical to confirm specific part numbers available

SpO2 Patient Cable (Required for Masimo LNCS Sensors)

Masimo LNC MP-10 (part 2281) Masimo LNCS dual-key patient cable for IntelliVue Masimo SET module and MMS — required to connect Masimo LNCS sensors to the M3001A Option A03C12 SpO2 port; confirmed compatible in Philips product documentation
Masimo LNCS-4-EXT (part 2021) Masimo LNCS extension cable, 4 ft — extends reach between Masimo LNCS sensor and LNC MP-10 patient cable at the M3001A A03C12 SpO2 port

Masimo LNCS SpO2 Sensors

Masimo 1863 (LNCS DC-I) Masimo LNCS adult reusable SpO2 sensor, 3 ft — for use with M3001A Option A03C12 via LNC MP-10 patient cable
Masimo 1864 (LNCS DC-IP) Masimo LNCS pediatric reusable SpO2 sensor, 3 ft — for use with M3001A Option A03C12 via LNC MP-10 patient cable
Masimo 2653 (LNCS DBI) Masimo LNCS neonatal/infant reusable SpO2 sensor — for use with M3001A Option A03C12 via LNC MP-10 patient cable
Masimo LNCS disposable sensors Adult, pediatric, neonatal, and multisite disposable LNCS sensors compatible with M3001A Option A03C12 via LNC MP-10 cable — contact IPR Medical to confirm specific sensor availability

NIBP Cuffs and Hoses

M1599B Philips NIBP single hose, male-to-female metal connector — replacement NBP hose compatible with M3001A
M3918A Philips NIBP single hose — replacement NBP hose compatible with M3001A
Adult NIBP cuffs Single-patient and reusable adult NBP cuffs compatible with the M3001A NBP hose connection — contact IPR Medical to confirm sizing and part number availability
Pediatric / neonatal NIBP cuffs Pediatric and neonatal cuff sizes compatible with the M3001A — contact IPR Medical to confirm current availability

Cables and Connectivity

MSL cable Measurement Link cable — connects the M3001A to the host IntelliVue monitor when the module is not directly docked; carries power, data, and network communication

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Reviews