Philips IntelliVue M3001A Multi-Measurement Module | Option A03C18, 12-Lead ECG, Masimo SET SpO2, IBP & Temp

$1,595.00 Original price was: $1,595.00.$1,395.00Current price is: $1,395.00.

The Philips IntelliVue M3001A (Option A03C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Masimo SET SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration with Masimo LNCS sensor compatibility. The A03C18 is the direct Masimo SET equivalent of the A01C18 and A02C18: clinically identical in every measurement capability, with Masimo LNCS sensors connecting via the Masimo LNC MP-10 dual-key patient cable (part 2281). As with all M3001A C18 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.

Part Number / Option M3001A, Option A03C18
Parameters Monitored ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Masimo SET SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)
SpO2 Technology Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection
12-Lead ECG Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported
IBP / Temp Port One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this port
Host Monitor Compatibility IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)
Data Storage Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

SKU: philips-intellivue-m3001a-a03c18 Categories: , Brand:
Send In Philips IntelliVue M3001A Multi-Measurement Module | Option A03C18, 12-Lead ECG, Masimo SET SpO2, IBP & Temp for Repair

Philips IntelliVue M3001A — Specifications (Option A03C18)


Manufacturer Philips Healthcare
Model IntelliVue Multi-Measurement Module (MMS)
Part Number / Catalog Number M3001A
Option Covered by This Listing A03C18 — Masimo SET SpO2, 3/5/12-lead ECG, NBP, plus one combined Invasive Pressure/Temperature channel (the C18 option incorporates both C12 and C06 measurement packages)
Device Classification Multi-parameter Multi-Measurement Module (MMS) for use with IntelliVue host patient monitors
Intended Use Acquisition and transmission of physiological measurement data — including 12-lead ECG, arrhythmia, ST, respiration, SpO2, NBP, and invasive pressure or temperature — to a compatible IntelliVue host patient monitor. The MMS stores patient demographics, trends, and settings and supports seamless patient data transfer between compatible host monitors.
Parameters — Option A03C18 Full Package ECG (3-lead, 5-lead, and 12-lead), EASI ECG, Arrhythmia, ST Segment (up to 12-lead analysis), QT/QTc, Respiration (impedance), Masimo SET SpO2 / Pleth, Pulse Rate, NBP (oscillometric), Invasive Pressure OR Temperature (shared port)
ECG Leads 3-lead, 5-lead, and conventional 12-lead (10-electrode lead set) monitoring; EASI 12-lead derived ECG available using 5-electrode placement
12-Lead ECG Capability Conventional 12-lead ECG capture providing diagnostic signal quality as defined in the ANSI/AAMI EC11-1991 standard when used with IntelliVue host monitors; ECG data can be transmitted to and stored in compatible ECG management systems via the IntelliVue Information Center iX
EASI ECG Yes — EASI lead placement provides 12-lead ECG data using only 5 electrodes; reduces setup time and patient connection complexity
Arrhythmia Detection Yes — full arrhythmia monitoring and alarm capability via host monitor
ST Segment Analysis Yes — up to 12-lead ST segment monitoring with alarms at the bedside; ST Map visualization available via host monitor display
QT/QTc Monitoring Yes — measured QT interval, heart-rate corrected QTc value, and QTc variation tracking relative to a stored baseline
NIBP Method Oscillometric; adult, pediatric, and neonatal modes with manual, auto, and stat measurement options
SpO2 Technology Masimo SET SpO2 (Option A03) — for use with Masimo LNCS sensors; connection requires the Masimo LNC MP-10 dual-key patient cable (Masimo part 2281)
Invasive Pressure / Temperature — C18 Channel One combined connector (red/brown) supports either an invasive pressure transducer or a temperature probe. Per OEM service documentation, invasive pressure and temperature cannot be used simultaneously on this port — this constraint applies to both C06 and C18 configurations. To monitor both simultaneously, an MMS extension (M3012A or M3015A) is required.
Trend Storage Up to 8 hours of trend data at 1-minute resolution for all numeric parameters, stored within the MMS itself
Data Retention While Disconnected Patient demographics, trends, and active parameter settings retained in the MMS for up to 6 hours while disconnected from a host monitor
Connection to Host Monitor Direct cable-free attachment to rear of compatible IntelliVue host monitor, or via MSL (Measurement Link) cable for remote placement in patient vicinity
Host Monitor Compatibility Philips IntelliVue MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90; MX-series monitors; M3046A (M/M4 series, Release E and later)
Optional MMS Extensions M3015A (sidestream CO2 + additional press/temp); M3016A (mainstream CO2); M3012A (additional invasive pressure/temperature/CO2) — extensions add measurement channels without replacing the C18 connector
Power Source Powered by host monitor via MSL connection; no independent battery or AC power supply
Preventive Maintenance NBP calibration test required once every two years per OEM service documentation
Regulatory FDA 510(k) cleared; product code MHX (Class II); CE marked

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips or Masimo.

Overview

The Philips IntelliVue M3001A (Option A03C18) is the most fully featured single-module configuration available in the M3001A family for facilities using Masimo LNCS sensors. The C18 designation combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module capable of acquiring 3-, 5-, and 12-lead ECG — including EASI-derived 12-lead ECG using only 5 electrodes — full arrhythmia and ST analysis, QT/QTc monitoring, impedance respiration, Masimo SET SpO2, oscillometric NBP, and either invasive blood pressure or temperature, all within a single plug-and-play module that docks directly to any compatible IntelliVue host monitor. The A03C18 is the direct Masimo SET equivalent of the A01C18 and A02C18: clinically identical in measurement capability across every parameter, with the SpO2 interface built around the Masimo SET circuit and LNCS sensors connecting via the LNC MP-10 dual-key patient cable (part 2281). As with all M3001A C18 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously — confirmed in Philips OEM service documentation for both the C06 and C18 options. Patient demographics, up to eight hours of trend data at one-minute resolution, and active measurement settings are stored in the module and travel with the patient between IntelliVue host monitors.


12-Lead ECG — Conventional Capture and EASI

The C18 option provides conventional 12-lead ECG capture using a 10-electrode lead set connected to a compatible 10-lead trunk cable, delivering diagnostic signal quality as defined in the ANSI/AAMI EC11-1991 standard when used with a compatible IntelliVue host monitor. Any number of electrodes between 3 and 10 can be used for ongoing ECG monitoring using conventional lead placements, giving clinical teams flexibility to apply fewer electrodes for routine rhythm monitoring and the full 10-electrode set when a documented 12-lead capture is required. When connected to the IntelliVue Information Center iX, 12-lead ECG captures can be transmitted to and stored in a compatible ECG management system, and previously acquired ECGs can be retrieved at the bedside. EASI ECG provides a parallel path to 12-lead data using only 5 electrodes in the EASI placement configuration, deriving 12-lead waveforms mathematically from the 5-electrode signal. EASI reduces the number of patient connections, minimizes interference with clinical procedures, and improves patient comfort during extended monitoring — particularly useful in post-operative recovery and transport settings where chest access is limited. Up to 12-lead ST segment analysis with configurable alarm thresholds and QT/QTc interval monitoring are also included, providing comprehensive cardiac surveillance well beyond routine arrhythmia detection.


The C18 Channel — Invasive Pressure or Temperature

The C18 option includes the same combined invasive pressure and temperature connector found in the C06 configuration. This single connector accepts either an invasive pressure transducer (colored red) or a temperature probe (colored brown), enabling the module to deliver arterial line pressure waveforms and numerics — systolic, diastolic, and mean — or continuous temperature monitoring depending on which device is connected. A critical operational detail confirmed in Philips OEM service documentation is that invasive pressure and temperature cannot be used simultaneously on this connector, and this constraint applies to both C06 and C18 configurations equally. If simultaneous pressure and temperature monitoring is required, an MMS extension module such as the M3012A or M3015A must be added. The invasive pressure channel supports zeroing via a dedicated button on the module and is compatible with standard Philips-approved invasive pressure transducer kits and adapter cables for BD, Utah, and B. Braun connector styles.


Masimo SET SpO2 in the C18 Configuration

The A03C18 uses the same Masimo SET SpO2 interface found in the A03 and A03C06 configurations, providing SpO2 saturation, pulse rate, and a real-time plethysmogram waveform. Masimo SET is designed to maintain measurement accuracy during patient motion and low perfusion conditions — characteristics particularly relevant in cardiovascular ICU and transport environments where the A03C18 is most commonly deployed, and where hemodynamic instability or artifact-prone conditions are more likely. Masimo LNCS sensors connect to the module’s SpO2 port via the Masimo LNC MP-10 dual-key patient cable (part 2281), confirmed in Philips product documentation as the appropriate connection method for IntelliVue Masimo SET modules. The dual-key design prevents incorrect cable orientation in fast-paced clinical environments. The addition of 12-lead ECG and the C18 pressure/temperature channel does not affect the Masimo SET interface or sensor compatibility. Facilities already running Masimo LNCS sensors on A03, A03C06, or A03C12 modules will find the A03C18 uses identical sensors and the same LNC MP-10 cable.


A03C18 vs. A03C06 and A03C12 — Understanding the Option Structure

The three C-option suffixes in the M3001A A03 family represent distinct additions to the A03 standard parameter set. The C06 adds the invasive pressure/temperature channel only, with no 12-lead ECG. The C12 adds conventional 12-lead ECG only, with no invasive pressure or temperature. The C18 combines both. For facilities that need both 12-lead ECG documentation and at least one hemodynamic or temperature measurement in a single Masimo SET MMS module, the A03C18 is the only configuration that delivers both without requiring a separate module or extension. For facilities that need only one of those additions, the A03C06 or A03C12 is the more focused and typically less costly selection. The invasive pressure/temperature constraint — that pressure and temperature cannot be used simultaneously on the module’s single shared connector — applies equally to the A03C06 and A03C18. Facilities that require simultaneous pressure and temperature alongside 12-lead ECG in a Masimo SET configuration should source the A03C18 paired with an M3012A or M3015A extension.


Patient Data Portability and Trend Storage

The M3001A A03C18 stores its complete patient record internally. Up to eight hours of numeric trend data at one-minute resolution — spanning ECG-derived values, SpO2, respiration, NBP, and invasive pressure or temperature — is held within the module rather than on the host monitor. Patient demographic information, active measurement settings including ECG lead configuration and display preferences, and NBP calibration data are also resident in the module. When the A03C18 docks to a new IntelliVue host, this complete record uploads automatically without manual re-entry, and both 12-lead ECG capability and the pressure channel zeroing settings are immediately available without reconfiguration. The module retains the full patient record for up to six hours while disconnected, supporting transport between the ICU and OR, imaging, or procedure areas without data loss.


MMS Extensions and Simultaneous Pressure and Temperature

For facilities that need simultaneous invasive pressure and temperature monitoring alongside the A03C18’s 12-lead ECG capability, MMS extension modules can supplement the single C18 connector. The M3012A Measurement Server Extension adds an additional pressure and temperature channel, enabling the C18 connector and the extension’s channels to be used concurrently — in practice allowing one channel for invasive pressure and one for temperature at the same time. The M3015A extension adds sidestream CO2 capnography and an additional pressure/temperature channel. The M3016A adds mainstream CO2. These extensions attach physically to the M3001A and inherit power and network connectivity from the host monitor through the module, requiring no separate power supplies or additional MSL cables.


Host Monitor Connectivity and System Integration

The M3001A A03C18 connects to compatible IntelliVue host monitors in either the direct-dock configuration or the remote configuration via MSL cable. Once connected, all monitoring, alarm, and configuration functions are managed through the host monitor’s interface. The A03C18 is compatible with the full IntelliVue MP-series platform (MP20 through MP90), the MX-series monitors, and the M3046A (M/M4 series) running Release E or higher software. When the host monitor is networked to the IntelliVue Information Center, all measurement data from the A03C18 — including 12-lead ECG captures, invasive pressure waveforms, and temperature — flows transparently for central monitoring, trend archiving, ECG storage and retrieval, and clinical reporting.


IPR Medical — Buy, Sell, Repair, and Parts

IPR Medical is a secondary market specialist for Philips IntelliVue patient monitoring equipment, including the M3001A across all option configurations. For the M3001A A03C18, IPR Medical purchases units in various conditions, sells tested and refurbished modules, and provides repair services for component-level issues including the NBP pneumatic assembly, Masimo SET SpO2 interface circuitry, invasive pressure and temperature interface, ECG acquisition hardware, and MSL connectivity. IPR Medical also stocks commonly requested accessories for the A03C18, including 10-lead ECG trunk cables and leadsets for 12-lead capture, 5-lead and 6-lead cables for standard and EASI monitoring, the Masimo LNC MP-10 patient cable (part 2281), Masimo LNCS sensors, NIBP cuffs and hoses, IBP adapter cables, temperature probes, and MSL cables. Contact our team to confirm current availability, discuss configuration requirements, or request a service assessment.

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips or Masimo.

Weight 1 lbs
Dimensions 8 × 6 × 4 in

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the Philips IntelliVue M3001A (Option A03C18). The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.


MMS Extension Modules

M3012A Hemodynamic/Pressure/Temperature MMS Extension — adds an additional invasive pressure channel and temperature channel, enabling simultaneous use of pressure and temperature when combined with the A03C18’s shared C18 connector
M3015A Sidestream CO2 Measurement Server Extension — attaches to the M3001A to add sidestream capnography plus an additional pressure/temperature channel; powered via host monitor MSL connection
M3016A Mainstream CO2 Measurement Server Extension — attaches to the M3001A to add mainstream capnography; powered via host monitor MSL connection

ECG Cables and Leadsets — 12-Lead

M1665A 10-lead trunk cable (12-pin connector) — for conventional 12-lead ECG capture on the M3001A A03C18; pair with one chest leadset and one limb leadset for full 10-electrode application
M1663A / M1949A Alternative 10-lead trunk cables (12-pin connector) — compatible with M3001A C12/C18 for 12-lead ECG applications; contact IPR Medical to confirm availability
Chest leadsets (AAMI) Precordial chest leadsets for use with 10-lead trunk cables on M3001A A03C18 — contact IPR Medical to confirm specific part numbers available
Limb leadsets (AAMI) Limb leadsets for use with 10-lead trunk cables on M3001A A03C18 — contact IPR Medical to confirm specific part numbers available

ECG Cables and Leadsets — 3-Lead, 5-Lead, and EASI

M1668A 5-lead ECG trunk cable (12-pin connector) — for 5-lead monitoring and EASI ECG configurations on the M3001A A03C18; also accepts 3-lead sets
M1667A 6-lead trunk cable (12-pin connector) — for 6-lead and EASI ECG monitoring on the M3001A A03C18; also accepts 3-lead and 5-lead sets
M1669A 3-lead ECG trunk cable — compatible with M3001A for 3-lead monitoring configurations
M1977A 5-lead ECG set, direct-connect pinch/grabber leadwires — for use with M3001A compatible trunk cables (AAMI color coding)

SpO2 Patient Cable (Required for Masimo LNCS Sensors)

Masimo LNC MP-10 (part 2281) Masimo LNCS dual-key patient cable for IntelliVue Masimo SET module and MMS — required to connect Masimo LNCS sensors to the M3001A Option A03C18 SpO2 port; confirmed compatible in Philips product documentation
Masimo LNCS-4-EXT (part 2021) Masimo LNCS extension cable, 4 ft — extends reach between Masimo LNCS sensor and LNC MP-10 patient cable at the M3001A A03C18 SpO2 port

Masimo LNCS SpO2 Sensors

Masimo 1863 (LNCS DC-I) Masimo LNCS adult reusable SpO2 sensor, 3 ft — for use with M3001A Option A03C18 via LNC MP-10 patient cable
Masimo 1864 (LNCS DC-IP) Masimo LNCS pediatric reusable SpO2 sensor, 3 ft — for use with M3001A Option A03C18 via LNC MP-10 patient cable
Masimo 2653 (LNCS DBI) Masimo LNCS neonatal/infant reusable SpO2 sensor — for use with M3001A Option A03C18 via LNC MP-10 patient cable
Masimo LNCS disposable sensors Adult, pediatric, neonatal, and multisite disposable LNCS sensors compatible with M3001A Option A03C18 via LNC MP-10 cable — contact IPR Medical to confirm specific sensor availability

Invasive Pressure Accessories

684081 Philips IBP adapter cable — male 12-pin, 13 ft — to BD connector style; for use with the M3001A A03C18 invasive pressure port
650-206 Philips IBP adapter cable — male 12-pin, 13 ft — to Utah connector style; for use with the M3001A A03C18 invasive pressure port
M1634A Philips IBP adapter cable — male 12-pin, 13 ft — to B. Braun connector style; for use with the M3001A A03C18 invasive pressure port
Disposable pressure transducer kits Single-use invasive pressure transducer kits compatible with the M3001A C18 pressure channel — contact IPR Medical to confirm compatible transducer brands and part numbers for your facility’s protocol

Temperature Probes

M21078A Philips adult reusable skin temperature sensor — round 2-pin connector, 9 ft; compatible with M3001A A03C18 temperature port
21075A Philips adult reusable rectal temperature sensor — round 2-pin connector, 9 ft; compatible with M3001A A03C18 temperature port
21082A Philips temperature probe adapter — female mono plug to rectangular 2-pin connector, 9 ft; for use with M3001A A03C18 temperature port
DHP-30-AD0 Philips temperature adapter — rectangular plug to rectangular 2-pin connector, 9 ft; for use with M3001A A03C18 temperature port
DHP-AD0 Philips temperature adapter — female mono plug to round 2-pin connector, 1 ft; for use with M3001A A03C18 temperature port

NIBP Cuffs and Hoses

M1599B Philips NIBP single hose, male-to-female metal connector — replacement NBP hose compatible with M3001A
M3918A Philips NIBP single hose — replacement NBP hose compatible with M3001A
Adult NIBP cuffs Single-patient and reusable adult NBP cuffs compatible with the M3001A NBP hose connection — contact IPR Medical to confirm sizing and part number availability
Pediatric / neonatal NIBP cuffs Pediatric and neonatal cuff sizes compatible with the M3001A — contact IPR Medical to confirm current availability

Cables and Connectivity

MSL cable Measurement Link cable — connects the M3001A to the host IntelliVue monitor when the module is not directly docked; carries power, data, and network communication

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.