IPR Medical

AAMI Compatible IBP Adapter Cable with BD (Argon) Connector — IBP-AM-BD40

$62.50

This is a compatible, aftermarket replacement IBP adapter cable designed for use with AAMI-standard patient monitors paired with Argon/BD disposable transducers. Part number IBP-AM-BD40 features a round, male keyed 6-pin distal connector (AAMI monitor side) and a BD (Argon) proximal connector (transducer side). The cable is approximately 4.0 meters (13 ft) in length, constructed with a TPU jacket, latex-free materials, and is reusable. It is not an OEM product and carries no affiliation with any original manufacturer.

This compatible IBP adapter cable is suitable for a broad range of AAMI-standard monitors including Spacelabs, Invivo, Welch Allyn, Philips, Mindray/Datascope, Stryker/Medtronic/Physio Control Lifepak, Zoll, and many others — making it a versatile choice for biomedical departments managing diverse monitoring environments. IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Contact our team at 855-477-8866 or cs@iprmed.com.

SKU: aami-ibp-adapter-cable Categories: , Tags: , ,
Send In AAMI Compatible IBP Adapter Cable with BD (Argon) Connector — IBP-AM-BD40 for Repair

Part Number IBP-AM-BD40
Category IBP Adapter Cable
Condition Aftermarket Compatible (Not OEM)
Total Cable Length 4.0 m (approx. 13 ft)
Distal Connector (Monitor Side) Round, Male 6-Pin Connector, Keyed (AAMI Standard)
Proximal Connector (Transducer Side) BD (Argon) Connector
Cable Color Gray
Cable Diameter 4 mm
Cable Material TPU Jacket
Latex-Free Yes
Sterile No
Reusable Yes
Packaging Type Bag
Packaging Unit 1
Weight 0.6 lb
Certifications FDA, CE, ISO 10993-1/5/10, TUV, RoHS Compliant

Compatible Monitor Models

Manufacturer Compatible Models
AAMI All AAMI-Standard Monitors
Bard Medical H8000
Dixtal DX 2020, DX 2021, DX 2023
Edan iM8, iM80
Generra 710C
Invivo 3500, 3550, 4500 Plus, Escort 100, Escort 200, Escort 300, M12, Millennia, Omnitrak 4000
Ivy Biomedical 400, 700
Mindray > Datascope DPM4, DPM5, PM 9000 Express, Passport
Mortara > Burdick 3100
PaceTech Vitalmax 4000
Philips 5microvolt, 78205, 8805
Smiths Medical > BCI 9100 Series, 9200 Advisor Series
Spacelabs 300, 400, 500, 600, 700 Surgical Series, 90308, 90311, 90331, 90402, 90403, 90470, 90496, 90603A, 91496, Alpha 7, Alpha PC, MOD-CD, PC Express, Scout TPC 90496, Tel/Vitatek
Stryker > Medtronic > Physio Control Lifepak 12, Lifepak 15
Tektronix 400 Series
Vitalert 2000
Welch Allyn 106EL, Encore, PIC, Propaq 102, Propaq 104, Propaq 106 Acuity, Propaq 205
Zoll M Series, Propaq MD, Thermogard Xp, X Series

Cross Reference / Interchange Part Numbers

Manufacturer Part Number
Alaris 684085
Argo Biomedical ARIBP-AM-BD40
Cables and Sensors IC-6P-BD0
Cadmet 86916-OR
Datascope 001C-30-70758
DEAM 890283-IBP-AM-BD40
Draeger 2606488
DTG BD-684085
Edan M13-36087
Gopher Medical GMIBP-AM-BD40
K2 Medical DT684085
M&R Medical IC-6P-BD0
MARS MARS-DR-000008
Medten IBP-AM-BD40
Mindray 6200-30-09743, 6000-10-02106
Orantech IBP-AM-BD40
Revanix RVBIBPAMBD401
Spacelabs 690-0021-00
Unimed BC-6P-BD
Viamed 6015223

IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment including IBP cables and accessories. Contact us at 855-477-8866 or cs@iprmed.com.

What Is the IBP-AM-BD40 IBP Adapter Cable?

The IBP-AM-BD40 is a compatible, aftermarket invasive blood pressure (IBP) adapter cable engineered to connect AAMI-standard patient monitors to BD (Argon) disposable pressure transducers. It bridges the monitor’s AAMI 6-pin input port to the industry-standard BD connector used on Argon-style disposable transducers, enabling accurate arterial and venous pressure waveform acquisition at the bedside. This cable is not an OEM product and is not manufactured by, affiliated with, or endorsed by any original equipment manufacturer. It is offered as a cost-effective compatible replacement for facilities managing high-volume IBP monitoring needs.


Compatible Monitor Models

This compatible IBP adapter cable is designed to function with a wide range of AAMI-standard monitors across numerous manufacturers. Confirmed compatible systems include Spacelabs 90308, 90311, 90331, 90402, 90403, 90470, 90496, and the full Alpha and PC Express series; Invivo 3500, 3550, 4500 Plus, Escort 100, Escort 200, Escort 300, M12, Millennia, and Omnitrak 4000; Welch Allyn 106EL, Encore, PIC, Propaq 102, Propaq 104, Propaq 106 Acuity, and Propaq 205; Philips 5microvolt, 78205, and 8805; Mindray/Datascope DPM4, DPM5, PM 9000 Express, and Passport; Stryker/Medtronic/Physio Control Lifepak 12 and Lifepak 15; Zoll M Series, Propaq MD, Thermogard Xp, and X Series; Smiths Medical/BCI 9100 and 9200 Advisor Series; Edan iM8 and iM80; Dixtal DX 2020, DX 2021, and DX 2023; Ivy Biomedical 400 and 700; PaceTech Vitalmax 4000; Mortara/Burdick 3100; Tektronix 400 Series; Vitalert 2000; Generra 710C; and Bard Medical H8000. It is also rated for use with all general AAMI-standard monitoring platforms.


Design and Construction

The IBP-AM-BD40 measures approximately 4.0 meters (13 ft) in total length, providing clinicians with adequate reach between the bedside monitor and the transducer setup without introducing unnecessary slack. The cable jacket is constructed from thermoplastic polyurethane (TPU), a material selected for its resistance to kinking, flex fatigue, and repeated disinfection cycles common in acute care environments. The distal (monitor-side) connector is a round, male keyed 6-pin plug conforming to the AAMI standard, ensuring a secure, orientation-specific connection that prevents misalignment. The proximal (transducer-side) connector is the BD (Argon) format, compatible with BD-style disposable pressure transducers widely used in operating rooms, ICUs, and critical care settings. The cable is latex-free, reusable, non-sterile, and packaged individually in a sealed bag. It carries FDA, CE, ISO 10993, TUV, and RoHS compliance, meeting the performance and safety expectations of clinical biomedical environments.


When to Replace Your IBP Adapter Cable

IBP adapter cables are subject to repeated mechanical stress from connection cycling, patient repositioning, and ongoing disinfection protocols. Biomedical technicians and clinical staff should inspect these cables routinely for visible jacket damage, fraying at the strain reliefs, intermittent pressure readings, or failure to lock securely at either connector end. Erratic or flatlined IBP waveforms that cannot be attributed to the transducer or monitor independently often indicate cable degradation. Keeping compatible replacement cables like the IBP-AM-BD40 on hand eliminates extended downtime and maintains uninterrupted hemodynamic monitoring capability across the unit.


Cross Reference and Interchange Part Numbers

The IBP-AM-BD40 is referenced under numerous part numbers across the industry, allowing biomedical procurement teams to source this cable regardless of which supplier catalog they use. Medten and Orantech both list it as IBP-AM-BD40. The Cables and Sensors and M&R Medical equivalent is IC-6P-BD0. Alaris references it as 684085, with DTG using the related designation BD-684085 and K2 Medical listing it as DT684085. Datascope carries it as 001C-30-70758, while Mindray lists it under two part numbers: 6200-30-09743 and 6000-10-02106. Spacelabs references it as 690-0021-00. Additional cross-references include Argo Biomedical ARIBP-AM-BD40, Cadmet 86916-OR, DEAM 890283-IBP-AM-BD40, Draeger 2606488, Edan M13-36087, Gopher Medical GMIBP-AM-BD40, MARS MARS-DR-000008, Revanix RVBIBPAMBD401, Unimed BC-6P-BD, and Viamed 6015223. These cross-references are provided to assist biomedical procurement teams in verifying compatibility when sourcing replacement cables across different supplier catalogs and purchasing systems.


Why Source IBP Cables from IPR Medical?

IPR Medical is an established resource for biomedical engineers, materials managers, and clinical procurement teams sourcing patient monitoring accessories and repair parts. We maintain stock of compatible IBP adapter cables in multiple connector configurations to support rapid replacement across a wide range of monitoring platforms. Whether you need a single replacement cable or are standardizing inventory for an entire fleet of monitors, IPR Medical offers the product knowledge and parts availability to meet your facility’s needs. Our team is experienced with infusion pumps, patient monitoring equipment, and related accessories across all major OEM platforms.

IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment including IBP cables and accessories. Contact us at 855-477-8866 or cs@iprmed.com.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.