B Braun Perfusor Space Version U
The B. Braun Perfusor® Space® Version U (software 588U) is a precision syringe infusion pump designed for critical care, anesthesia, NICU, PICU, OR, and emergency settings in adult, pediatric, and neonatal patients. Version U is the most advanced software iteration of the Perfusor Space platform for the US market, adding Target Controlled Infusion (TCI/TIVA), Take Over Mode (TOM) for seamless syringe-to-syringe handoff, AutoProgramming with EHR integration, wireless drug library upload, and barcoding to the core Perfusor Space feature set.
Delivering ±2% accuracy from 0.01 ml/h up to 60 ml/h (depending on syringe size), with nine adjustable occlusion pressure levels, an automatic piston brake to prevent inadvertent bolus during syringe changes, and a post-occlusion bolus reduction system, the Perfusor Space is one of the most capable syringe pumps in clinical use. It is the first syringe pump to receive FDA clearance for air and road transport. The KeyGuard non-numeric keypad prevents zero-vs-decimal programming errors, and the pump integrates into the B. Braun Space System — stacking up to three pumps on a single pole clamp and connecting to SpaceStation for wireless fleet management.
Brand new units may be available. Please contact us directly for more information.
IPR Medical buys, sells, repairs, and stocks parts for the B. Braun Perfusor Space, keeping these industry-standard pumps in service for hospitals and clinical facilities.
B. Braun Perfusor® Space® Syringe Infusion Pump — Version U (Software 588U)
Advanced syringe infusion pump for critical care, anesthesia, NICU, PICU, OR, and emergency settings. Version U adds TCI/TIVA, Take Over Mode, Auto Programming with EHR integration, wireless drug library upload, and barcoding to the core Perfusor Space platform. ± 2% accuracy, nine occlusion levels, automatic piston brake, post-occlusion bolus reduction, FDA clearance for air and road transport. IPR Medical buys, sells, repairs, and stocks parts for the Perfusor Space Version U.
| Manufacturer | B. Braun Melsungen AG |
| Software Version | 588U (US) |
| Intended Use | Intermittent or continuous delivery of parenteral fluids, enteral fluids, medications, blood and blood products; adults, pediatrics, and neonates; intravenous, intra-arterial, subcutaneous, epidural, and enteral routes; healthcare facilities and medical ground and air transport |
| Compatible Syringe Sizes | 2/3 ml, 5/6 ml, 10/12 ml, 20 ml, 30/35 ml, 50/60 ml — automatic syringe size recognition |
| Flow Rate Range — by Syringe | 2/3 ml: 0.01–25 ml/h | 5/6 ml: 0.01–50 ml/h | 10/12 ml: 0.01–50 ml/h | 20 ml: 0.01–100 ml/h | 30/35 ml: 0.01–100 ml/h | 50/60 ml: 0.01–200 ml/h (optional 0.01–999.9 ml/h) |
| Flow Rate Increments | 0.01 ml/h steps up to 99.99 ml/h; 0.1 ml/h steps from 100.0–999.9 ml/h |
| Accuracy | ± 2% per IEC/EN 60601-2-24 |
| Bolus Rate — by Syringe | 2/3 ml: 1–150 ml/h | 5/6 ml: 1–300 ml/h | 10/12 ml: 1–500 ml/h | 20 ml: 1–800 ml/h | 30/35 ml: 1–1,200 ml/h | 50/60 ml: 1–1,800 ml/h |
| Bolus Accuracy | ± 2% typical; max post-bolus reduction volume ≤0.2 ml |
| VTBI | 0.1–9,999 ml |
| KVO Rate | 3 ml/h (rates >10 ml/h); 1 ml/h (rates <10 ml/h); equals set rate (rates <1 ml/h, default 0.1 ml/h) |
| Therapy Profiles | Dose Rate Calculation, Dose Over Time, Loading Dose, Ramp and Taper Mode, Program Mode (up to 25 steps), Intermittent Mode, Bolus with Dose and Time, Manual Bolus, PCA, TCI/TIVA (optional), Take Over Mode (TOM), KVO |
| TCI / TIVA | Target Controlled Infusion available in Version U (optional); supports Propofol and Remifentanil TCI models; requires trained anesthesia personnel |
| Take Over Mode (TOM) | Automatically starts a second Perfusor Space at the same rate when the first runs empty — enables uninterrupted infusion during syringe changes on critical medications |
| Occlusion Pressure | 9 selectable levels from 1.45 psi to 17.4 psi (0.1–1.2 bar) |
| Safety Features | Automatic piston brake prevents inadvertent bolus during syringe change; post-occlusion bolus reduction software (≤0.2 ml); KeyGuard non-numeric keypad prevents zero-vs-decimal errors; max single fault volume 0.1 ml |
| Drug Library | Up to 1,500 drug names with therapy data and information stored in 30 categories; up to 50 care units and 15 patient profiles; drug-specific hard and soft limits, default values, and clinical advisories; DoseGuard software powered by FDB Infusion Knowledge |
| Wireless Drug Library Upload | Via SpaceStation — wireless fleet-wide drug library updates without physically handling each pump (requires WiFi battery, sold separately) |
| AutoProgramming & Barcoding | Accepts drug orders wirelessly from EHR system or from SpaceStation with SpaceCom; barcode scanning support for medication verification |
| Connectivity | Wireless (requires WiFi battery module, sold separately) and wired; SpaceStation integration for drug library updates, EHR autoprogramming, barcoding, staff call, and fleet management; USB via B. Braun CAN SP interface lead |
| Transport Clearance | First syringe pump FDA-cleared for air and road transport (rotary and fixed-wing ambulances, ground transport) |
| MR Conditional | Yes — when used with SpaceStation MRI |
| History Log | Up to 3,000 history entries; 100 events for system diagnostics |
| Alarm Volume | 9 levels; 59 dBA (level 1) to 74 dBA (level 9) |
| Classification | Type CF, defibrillation-proof; Class II (standalone); Class I in combination with SpaceStation; Class IIb per EU Directive 93/42/EEC |
| Water Resistance | IP22 (fluid-protected for horizontal usage) |
| Power — AC | 100–240V AC, 50/60 Hz (via SpaceStation or optional mains adapter) |
| Power — DC | 11–16V DC via Connection Lead SP 12V or SpaceStation |
| Battery — Standard (included) | Li-Ion battery included with all sales; approx. 17 hours at 5 ml/h; approx. 10 hours at 25 ml/h; recharge time approx. 6 hours. Does not support WiFi connectivity. |
| Battery — WiFi (sold separately) | WiFi functionality requires the B. Braun Battery Pack SP with WiFi — not included with standard sales, available for separate purchase through IPR Medical. Enables wireless drug library uploads, EHR AutoProgramming, and SpaceStation connectivity. Approx. 13 hours at 25 ml/h with WiFi inactive; approx. 3 hours at 5 ml/h with WiFi active. |
| Stacking | Up to 3 Space pumps per pole clamp; 1 pump per pole clamp during transport |
| Operating Environment | Temperature: 41 – 105°F; Humidity: 30 – 90% non-condensing; Pressure: 500 –1,060 mbar |
| Storage / Transport | Temperature: – 4 – 131°F; Humidity: 20 – 90% non-condensing; Pressure: 500 –1,060 mbar |
| Dimensions | 9.8″ W × 2.7″ H × 6.0″ D |
| Weight | Approx. 3 lbs (1.4 kg) |
IPR Medical buys, sells, repairs, and stocks parts for the B. Braun Perfusor Space Version U. WiFi battery modules available separately. Contact us for unit availability, parts inventory, repair turnaround, and pricing at 855-477-8866 or cs@iprmed.com.
Trademark Notice: B. Braun, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by B. Braun.
The most advanced Perfusor Space software for the US market
The Perfusor® Space® Version U runs software 588U — the most feature-complete US software version of B. Braun’s industry-standard syringe infusion platform. It adds Target Controlled Infusion (TCI/TIVA), Take Over Mode (TOM) for seamless syringe-to-syringe handoff, AutoProgramming with EHR integration, wireless drug library upload, and barcode medication verification to the already comprehensive Perfusor Space core. The underlying pump hardware is unchanged: ±2% accuracy, nine adjustable occlusion pressure levels, automatic piston brake, post-occlusion bolus reduction, and FDA clearance for air and road transport — all in a 3 lb package that stacks with up to two other Space pumps on a single pole clamp.
TCI / TIVA — Target Controlled Infusion
Version U enables TCI (Target Controlled Infusion) for compatible drug models including Propofol and Remifentanil. TCI calculates and continuously adjusts the infusion rate to maintain a target plasma or effect-site concentration entered by the clinician, rather than requiring manual rate programming. This is a significant feature for anesthesia departments running TIVA (Total Intravenous Anesthesia) protocols. TCI requires trained anesthesia personnel and should not be used simultaneously with a second infusion of the same agent.
Take Over Mode — uninterrupted infusion during syringe changes
Take Over Mode (TOM) allows a second Perfusor Space to automatically start infusing at the same rate the moment the first pump’s syringe runs empty. This enables truly uninterrupted delivery of high-risk medications — vasopressors, sedation, insulin, heparin — without the clinician manually restarting the second pump. Both pumps must be running the same drug at the same concentration, and a data connection must be active between the two pumps via SpaceStation.
AutoProgramming, EHR integration, and barcoding
Version U supports AutoProgramming — the pump can receive drug orders wirelessly directly from the EHR system or from SpaceStation with SpaceCom, pre-populating drug name, concentration, and dose parameters for clinician confirmation before infusion starts. Barcode scanning allows medication label verification at the pump to confirm the right drug and concentration are loaded before programming begins. These two features together close the loop between pharmacy, the EHR, and bedside administration — the core of a complete closed-loop medication safety workflow.
1,500-entry drug library with 30 categories and wireless updates
The Version U drug library holds up to 1,500 drug names with therapy data, drug-specific hard and soft dose limits, default values, and clinical advisories — organized into 30 categories with up to 50 care units and 15 patient profiles configurable per institution. DoseGuard software powered by FDB Infusion Knowledge supports library development and maintenance. Wireless drug library uploads via SpaceStation allow pharmacy to push library updates fleet-wide without physically handling each pump. Note that wireless functionality requires the B. Braun WiFi battery module, which is available for separate purchase and is not included with standard unit sales.
WiFi battery — available separately
All Perfusor Space Version U units sold by IPR Medical include a standard non-WiFi Li-Ion battery. To enable wireless connectivity — including wireless drug library uploads, EHR AutoProgramming, and SpaceStation communication — the B. Braun WiFi battery module is required and must be purchased separately. Contact IPR Medical to add a WiFi battery module to your order. Units can also be operated with a NiMH battery for extended runtime, also available separately.
Core safety architecture and FDA transport clearance
The Perfusor Space remains the first syringe pump FDA-cleared for air and road transport with those indications explicitly in the cleared labeling — the standard of care for critical care transport teams and flight nurses. The KeyGuard non-numeric keypad prevents zero-vs-decimal programming errors by design. The automatic drive arm retracts and the integrated piston brake engages during syringe changes to prevent inadvertent bolus. Post-occlusion bolus reduction software limits bolus after occlusion clearing to ≤0.2 ml. Maximum single-fault delivery volume is 0.1 ml.
IPR Medical — sales, repairs, and parts for the Perfusor Space Version U
IPR Medical buys, sells, repairs, and stocks replacement parts for the B. Braun Perfusor Space Version U. Whether you need a patient-ready refurbished unit, a WiFi battery module, a specific replacement component, or repair service on pumps already in your fleet, our biomedical technicians are ready to help.
IPR Medical buys, sells, repairs, and stocks parts for the B. Braun Perfusor Space Version U. WiFi battery modules available separately. Contact us for unit availability, parts inventory, repair turnaround, and pricing at 855-477-8866 or cs@iprmed.com.
Trademark Notice: B. Braun, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by B. Braun.
| Weight | 4 lbs |
|---|---|
| Dimensions | 12 × 12 × 12 in |
| Product Condition | Brand New, Recertified |
- AC Adapter
- Battery
- Pole Clamp
Reviews
There are no reviews yet.