Infusion Pump Repair

B Braun Perfusor Space Version U

$1,895.00

The Perfusor Space Syringe Pump is intended for use on adults, pediatrics, and neonates. It is the first syringe pump to receive FDA clearance for air and road transport. Weighing only 3 pounds, its compact design and flexible mounting positions allow for both vertical and horizontal delivery to accommodate IV and enteral infusions. Target Controlled Infusions (TCI) can be enabled for certain drugs.

 

Brand new units may be available. Please contact us directly for more information.

Send In B Braun Perfusor Space Version U for Repair

Baxter Sigma Spectrum

So here you will be able to find the specifications of the Baxter Sigma Spectrum infusion pump repair and Baxter sigma spectrum manual. Download Baxter Sigma Spectrum Infusion Pump Manual.

  • Specification:
    • Flow Rate Range: 0.1 – 99.99 mL/h in increments of 0.01 mL/h; 100.0 – 999.9 mL/h in increments of 0.1 mL/h
    • Flow Rate Tolerance: ± 2% in compliance with IEC/EN 60601-2-24
    • Delivery Volume:
      • 1 – 99.99 mL in increments of 0.01 mL
      • 0 – 999.0 mL in increments 0.1 mL
      • 1,000 – 9,999 mL in increments 1 mL
    • Power Requirement: 100 – 240 V AC~, 50/60 Hz
    • Battery Operating Time: (NiMH) 8 hours at 25mL/hr
    • Occlusion Alarms/ Pressure: 9 stages from 75 mmHg to 900 mmHg
    • KVOs:
      • Rate ≥ 10 mL/h: KVO rate 3 mL/h
      • Rate < 10 mL/h: KVO rate 1 mL/h
      • Rate < 1 mL/h: KVO rate = set rate (default setting is 0.1 mL/h)

    Other Software Versions:

    • F
    • G
    • U

description :

The Spectrum and Spectrum with Master Drug Library are suitable for many user facility applications such as, but not limited to, hospitals, outpatient care areas, home care, and ambulatory care services.

The Spectrum and Spectrum with Master Drug Library are intended to reduce operator interaction through guided programming, thereby helping to reduce errors associated with complex device programming. Parameter programming requires trained health care professional confirmation of limits and drug therapy to physician’s directive.

Features

  • Intercompatability with the Electronic Medical Record (ERM) to help improve clinical workflow and data documentation accuracy
  • A Dose Change alert can catch potential programming errors
  • Average 96% drug library compliance that maximizes use of the key safety feature
  • Large font with color display; easy-to-read screen with on-screen guidance
  • Standard, 802.11b Wireless, 802.11 b/g, and 802.11 a/b/g/n Wireless Battery Modules available
  • The built-in asset tracking capabilities will help quickly locate pumps for use and manage pump inventory when used in conjunction with an asset management solution

Related Keyphrase:

  • Baxter  Spectrum infusion pump repair
  • Baxter sigma spectrum manual
  • AC Adapter
  • Battery