Philips 989803143411 Compatible Fetal Event Marker Cable, Reusable, 9.8 ft (3.0 m)
The 989803143411 compatible fetal event marker cable (SKU FM-002) is a reusable aftermarket replacement (not OEM) with a 9.8 ft (3.0 m) cable length, packaged one per bag.
| Product | Fetal Event Marker Cable |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
| Replaces | Philips 989803143411 |
Works with: the monitor models listed in the Specifications tab. Browse more fetal monitoring accessories.
IPR Medical buys, sells, repairs, and stocks parts for fetal monitoring accessories and patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | FM-002 |
| Replaces OEM Part | Philips 989803143411 |
| Category | Cables & Sensors > Fetal |
| Product | Fetal Event Marker Cable |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Philips | Avalon FM20, Avalon FM40, Avalon FM50, FM30, M2702A, M2704A, M2705A |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | 989803143411 |
| Unimed | UREM-002 |
IPR Medical buys, sells, repairs, and stocks parts for fetal event marker cables and the monitors they serve. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, Avalon, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the 989803143411 Compatible Fetal Event Marker Cable?
The IPR Medical FM-002 is a compatible aftermarket (not OEM) fetal event marker cable that replaces OEM part 989803143411. It is a reusable fetal monitoring accessory with a 9.8 ft (3.0 m) cable length, and each one is supplied in its own bag. Confirm the OEM part number and your monitor model against the Specifications tab before ordering.
Compatible Monitor Models
The FM-002 is listed for a short group of monitor models, all shown in the Compatible Monitor Models table on the Specifications tab. Entries appear exactly as they are listed for this part, so some monitors are identified by name and others by model number. Look for either form of your monitor’s designation in the table, and contact IPR Medical if you would like help confirming the match.
Design and Construction
This event marker cable is made for repeated use and measures 9.8 ft (3.0 m) in length. Because it is reusable, it can be cleaned between patients according to facility protocol and returned to service for as long as routine inspection finds no damage. Every cable is individually bagged, which keeps spares organized in a supply room or on a unit.
When to Replace Your Fetal Event Marker Cable
Retire the cable when its jacket is split, crushed, or kinked, or when the connector housing is cracked, loose, or no longer seats securely. An event marker that responds only intermittently, or that works only while the cable is held in a certain position, also points to a cable fault. Trying a known-good cable on the same monitor is a quick way to tell a cable problem from a monitor problem.
Cross Reference and Interchange Part Numbers
OEM part 989803143411 is the reference number for this compatible cable. One aftermarket interchange number is also listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source Fetal Event Marker Cables from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. Our own technicians handle repair and testing in-house, and our team can help you match accessories like this cable to the monitors in your fleet. Browse more fetal monitoring accessories, or call 855-477-8866 for help with parts, repairs, and replacements.
IPR Medical buys, sells, repairs, and stocks parts for fetal event marker cables and the monitors they serve. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, Avalon, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.