Philips 989803136931 Compatible Adult/Pediatric NIBP Air Hose, 1-Tube, Female Bayonet Recept Plug, 9.8 ft (3.0 m)
The 989803136931 compatible NIBP air hose (SKU BPH-AS30-02M-02M) is a reusable aftermarket replacement (not OEM) with a 1-tube design, a Female Bayonet Recept BP plug, and a 9.8 ft (3.0 m) length, for use with a 1-tube bayonet cuff on adult and pediatric patients.
| Patient Size | Adult/Pediatric |
| Tube Configuration | 1-Tube (Single Tube) |
| BP Plug | Female Bayonet Recept |
| Used with Cuff | 1-Tube Bayonet Cuff |
| Hose Length | 9.8 ft (3.0 m) |
| Replaces | Philips 989803136931 |
Works with: the monitor models listed in the Specifications tab. Browse more NIBP hoses and accessories.
IPR Medical buys, sells, repairs, and stocks parts for NIBP air hoses and patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | BPH-AS30-02M-02M |
| Replaces OEM Part | Philips 989803136931 |
| Category | Cables & Sensors > NIBP |
| Hose Type | BP Air Hose |
| Patient Size | Adult/Pediatric |
| Tube Configuration | 1-Tube (Single Tube) |
| BP Plug | Female Bayonet Recept |
| Used with Cuff | 1-Tube Bayonet Cuff |
| Hose Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| American Diagnostic Corporation (ADC) | ADView 2 |
| Aspen | V1 |
| Biolight | M6, M69, M800 Handheld, M7000, M8000, M8500, M9000, M9500 |
| Bionet | BMP300 |
| Cardell | 9403 |
| Contec | CMS 5100, CMS 6000, CMS 7000, CMS 8000, CMS 9000 |
| Criticare / CSI | 506, 506 Series, 506DN, 506DN3, 506DNB, 506DNP3, 506DNT3, 506DNTP3, 506DNV3, 506DNVP3, 506DXNT2, 506DXNTP2, 506LN3, 506LNP3, 506LNT3, 506LNTP3, 506LNV3, 506LNVP3, 506N3, 506NP3, 506NT3, 506NTP3, 506NV3, 506NVP3, 507, 507EL, 507EL(Scholar III), 507EL/C, 507ELC2, 507MPS, 507NJC, 8100 (Poet Plus), 8100 Series, 8100E Series (nGenuity), 8100H Series (nCompass), nCompass, nGenuity |
| Datex-Ohmeda | enGuard CM5 |
| DRE | Waveline EZ MAX |
| Edan | Elite V5, F6 Express, F9, F9 Express, iM8, iM8A, iM8B, iM9, iM9A, iM50, iM60, iM60 VET, iM60GT, iM70, iM70 VET, iM80, iM80 VET, M3, M3A, M3B, M8, M8A, M8B, M9, M9A, M50, M80 |
| Invivo | MDE Escort Prism |
| Ivy Biomedical | 450C, CM5 |
| Masimo | Rad-97, Root |
| Mediana | V10 |
| Medica D | Logicare Series 2000 |
| Mindray / Datascope | Accutorr 3, Accutorr Plus, Accutorr V, DPM3, DPM4, DPM5, Duo, MEC 1000, MEC 1200, MEC 2000, Passport 2, Passport 2LT, Passport V, PM 5000, PM 6000, PM 7000, PM 7000 Standard, PM 8000, PM 8000 Express, PM 9000, PM 9000 Express, Spectrum OR, T5, Trio, V12, V21, V-Series, XG |
| Philips | 78332A, 862146 |
| Physio-Control | Lifepak 15 |
| Smiths Medical / BCI | 9200(Advisor), Mini Torr |
| Spacelabs | 90369, 91393 Xprezzon, 91496, Ultraview SL 2400, Ultraview SL 2700 |
| Sunnex | M8000A |
| Zoll | E Series, M Series, X Series |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | 989803136931, M3918A |
| Advanced Instrumentations | 01.59.036104 |
| AMC | HO-S15158-10 |
| American Diagnostic Corporation (ADC) | 9005BPC |
| Bionet | B-NBPCBL, 152600-022401, 130300-004800 |
| Contec | 2.3.11.00007 |
| Criticare / CSI | CAT 706 |
| Draeger | 2601195, 2606218 |
| Edan | 11.57.471291-10, M13-36036, 01.59.036118-11, 01.57.472338, 01.57.471005-11 |
| Invivo | E2810-06 |
| Ivy Biomedical | 2689-00-01 |
| Masimo | 25302 |
| Medtronic | RPAYACC034 |
| MEK | 14140010 |
| Midmark | 3-009-1000, 3-009-0100 |
| Mindray / Datascope | 0683-04-0004, 509B-30-06259, 1683-04-0004, 200683-04-0003 |
| Neoventa | P9001-00472 |
| Sage | H04-15-15 |
| Schiller | 0-87-0006/0-87-0007 |
| Spacelabs | 714-0018-02, 714-0018-00 |
| Sunnex | 15-100-0026 |
| Unimed | HS30-15-15, HS-15-15 |
IPR Medical buys, sells, repairs, and stocks parts for NIBP air hoses and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Masimo, or any other manufacturer or supplier named on this page. Philips, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the 989803136931 Compatible NIBP Air Hose?
The IPR Medical BPH-AS30-02M-02M is a compatible aftermarket (not OEM) NIBP air hose that replaces OEM part 989803136931. Rated for adult and pediatric use, it is a reusable single-tube hose that spans 9.8 ft (3.0 m) and works with a 1-tube bayonet cuff.
Compatible Monitor Models
Compatibility listings for this hose span many manufacturers. They include select Mindray / Datascope models such as the Passport 2, Spectrum OR, and Accutorr Plus, select Edan models such as the iM50 and iM70, select Criticare / CSI models including the 506 Series and nGenuity, and select Spacelabs models such as the Ultraview SL 2400. Select Zoll, Contec, Biolight, Bionet, and Ivy Biomedical models, along with the other brands listed, appear in the Compatible Monitor Models table on the Specifications tab together with the original equipment manufacturer’s own entries; confirm your exact model there before ordering.
Design and Construction
This hose has a 1-tube (single tube) configuration. Its BP plug is designated Female Bayonet Recept, and it is used with a 1-tube bayonet cuff, so check both the plug style and the cuff connection on your current setup before switching. The hose is 9.8 ft (3.0 m) long, rated for adult and pediatric patients, reusable, and supplied one per bag; clean it between patients according to your facility’s protocol.
When to Replace Your Adult/Pediatric NIBP Air Hose
Retire the hose when the tubing shows cracks, splits, flattened sections, or kinks that no longer straighten, or when a fitting is loose, cracked, or fails to lock. During use, watch for leak alarms, a cuff that inflates slowly or loses pressure, and blood pressure cycles that abort or need repeating. A quick swap to a known-good hose, with the same monitor and cuff, tells you whether the hose is responsible.
Cross Reference and Interchange Part Numbers
Besides OEM part 989803136931, this hose cross-references to Spacelabs 714-0018-00 and 714-0018-02, Mindray / Datascope 0683-04-0004, Draeger 2601195 and 2606218, and Edan M13-36036, among others. Interchange numbers from Bionet, Criticare / CSI, Midmark, Schiller, and the remaining brands are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source NIBP Air Hoses from IPR Medical?
IPR Medical, an ISO 9001:2015-certified independent service organization, stocks NIBP hoses such as the BPH-AS30-02M-02M alongside other parts for patient monitoring equipment and infusion pumps, which it also buys, sells, and repairs. Technicians on IPR Medical’s own staff perform its repairs in-house. To talk through hose options, call 855-477-8866, or look through more NIBP hoses and accessories.
IPR Medical buys, sells, repairs, and stocks parts for NIBP air hoses and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Masimo, or any other manufacturer or supplier named on this page. Philips, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.



















