IPR Medical

Philips 11CA40112 Compatible Temperature Adapter Cable, for 400 Series Probes, 9.8 ft (3.0 m)

$62.50

The 11CA40112 compatible temperature adapter cable (SKU TA-PH-YSI30) is a reusable aftermarket replacement (not OEM) with a 9.8 ft (3.0 m) length, for use with 400 Series temperature probes.

Product Temperature Adapter Cable
Temperature Technology 400 Series
Used With 400 Series Probes
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable
Replaces Philips 11CA40112

Works with: the monitor models listed in the Specifications tab. Browse more temperature probes and cables.

IPR Medical buys, sells, repairs, and stocks parts for patient monitors and their temperature accessories. Call 855-477-8866 or email cs@iprmed.com.

SKU: TA-PH-YSI30 Categories: ,
Send In Philips 11CA40112 Compatible Temperature Adapter Cable, for 400 Series Probes, 9.8 ft (3.0 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) TA-PH-YSI30
Replaces OEM Part Philips 11CA40112
Category Cables & Sensors > Temperature
Product Temperature Adapter Cable
Temperature Technology 400 Series
Used With 400 Series Probes
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Contec Patient Simulator MS400
Philips 78341A, 78342A, 78345A, 78346A, 78353A, 78353B, 78532B, 78534A, 78534B, 78834C, 862474, 862474 C3, 862478 C3, 863064, 863065, 863066, 863066 VM6, 863068, 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, 867030, 867033, 867036, 867039, 867040, 867041, A1, A3, C1, EarlyVue VS30, Efficia CM12, Efficia CM100, Efficia CM120, Efficia CM150, HeartStart MRx, IntelliVue MMS X2, IntelliVue MMX, IntelliVue MP2, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX800, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M1029A, M1094A, M1094B, M1166A, M1167A, M1175A, M1177A, M1205A, M1275A, M3001A, M3001A A01C06, M3001A A01C18, M3001A A02C06, M3001A A02C18, M3001A A03C06, M3001A A03C18, M3001A A04C06, M3001A A04C18, M3002A, M3002A MMS X2, M3012A, M3015A, M3015B, M3016A, M3046A (M4 chip), M3046A M3, M3535A, M3536A, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8102A, M8102A MP2, MX Series, P60E, SureSigns VM4, SureSigns VM6, SureSigns VM8, SureSigns VS3, Viridia 24, Viridia 24C, VS1
Welch Allyn Propaq CS

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Philips 11CA40112, 1331
Medtronic / Covidien 5020411A
Sage THP-30-AD
Smiths Medical C400-10, C400-10HP

IPR Medical buys, sells, repairs, and stocks parts for temperature adapter cables and the patient monitors they serve. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, IntelliVue, HeartStart, Efficia, SureSigns, Viridia, EarlyVue, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the 11CA40112 Compatible Temperature Adapter Cable?

The IPR Medical TA-PH-YSI30 is a compatible aftermarket (not OEM) temperature adapter cable that replaces OEM part 11CA40112. Its length is 9.8 ft (3.0 m), and it is meant for use with 400 Series temperature probes. Multiple patients can be served by the same adapter, since it is designed for reuse.


Compatible Monitor Models

Most of the models in the Compatible Monitor Models table on the Specifications tab belong to one OEM monitor brand. The table also lists the Welch Allyn Propaq CS and the Contec Patient Simulator MS400. Find your exact model, including any option code shown with it, before placing an order.


Design and Construction

The TA-PH-YSI30 works as the link between a 400 Series probe and the compatible equipment named in the table. Each adapter is bagged individually. It is a reusable accessory, so clean it between patients under your facility protocol and look over the jacket and both connectors before each use.


When to Replace Your 400 Series Temperature Adapter Cable

A temperature value that drops off the display, reads implausibly high or low, or shifts whenever the cable is moved usually points to a worn adapter. On inspection, look for a cracked or nicked jacket, kinks close to either connector, a probe connection that no longer seats firmly, and bent pins at the monitor connector. Swapping in a known-good adapter with the same probe is a quick way to tell an adapter fault from a probe or monitor fault.


Cross Reference and Interchange Part Numbers

This adapter is a compatible replacement for OEM part 11CA40112. To see the other OEM and aftermarket numbers on record for this adapter, open the Specifications tab, where they are grouped by brand under Cross Reference / Interchange Part Numbers.


Why Source Temperature Adapter Cables from IPR Medical?

Temperature readings depend on the probe, the adapter, and the monitor working together. On the parts side, IPR Medical buys, sells, repairs, and stocks components for patient monitors and infusion pumps; it is certified to ISO 9001:2015 as an independent service organization, and its own technicians handle repairs in-house. To order, ask about a repair, or check on a part, call 855-477-8866, or browse our temperature probes and cables.

IPR Medical buys, sells, repairs, and stocks parts for temperature adapter cables and the patient monitors they serve. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, IntelliVue, HeartStart, Efficia, SureSigns, Viridia, EarlyVue, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.