IPR Medical

Draeger 3368433 Compatible SpO2 Adapter Cable, for Use with Nellcor OxiSmart Sensors, 3.9 ft (1.2 m)

$60.00

The Draeger 3368433 compatible SpO2 adapter cable (SKU SA-028-12) is a reusable aftermarket replacement (not OEM) with a 3.9 ft (1.2 m) cable, for use with Nellcor OxiSmart sensors.

Cable Type SpO2 Adapter Cable
SpO2 Technology Nellcor OxiSmart
Cable Length 3.9 ft (1.2 m)
Lifecycle Reusable
Packaging 1 per bag
Replaces Draeger 3368433

Works with: select Draeger Infinity and SC models, such as the Infinity Delta, Infinity Vista, and SC 7000. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.

IPR Medical buys, sells, repairs, and stocks parts for Draeger monitoring equipment and SpO2 accessories. Call 855-477-8866 or email cs@iprmed.com.

SKU: SA-028-12 Categories: , Tags: , ,
Send In Draeger 3368433 Compatible SpO2 Adapter Cable, for Use with Nellcor OxiSmart Sensors, 3.9 ft (1.2 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) SA-028-12
Replaces OEM Part Draeger 3368433
Category Cables & Sensors > SpO2
Cable Type SpO2 Adapter Cable
SpO2 Technology Nellcor OxiSmart
Used With Nellcor OxiSmart sensors
Cable Length 3.9 ft (1.2 m)
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Draeger Infinity Delta, Infinity Gamma, Infinity Gamma XL, Infinity Kappa, Infinity MultiMed Pod, Infinity Vista, SC 6000, SC 6002XL, SC 7000, SC 8000, SC 9000, SC 9000X, SC 9000XL
Draeger / Air Shields Infinity Delta XL, Infinity Gamma X, Infinity Kappa XLT, Infinity Vista XL

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Draeger 3368433
Unimed U704-23

IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitors and SpO2 adapter cables. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Draeger, Nellcor, or any other manufacturer or supplier named on this page. Draeger, Nellcor, OxiSmart, Infinity, MultiMed, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Draeger 3368433 Compatible SpO2 Adapter Cable?

The IPR Medical SA-028-12 is a compatible aftermarket (not OEM) SpO2 adapter cable that replaces the Draeger 3368433. Designed for use with Nellcor OxiSmart sensors, it has a 3.9 ft (1.2 m) cable and is meant to be cleaned and put back into service rather than discarded after one patient.


Compatible Monitor Models

This adapter is listed for select Draeger models, among them the Infinity Delta, Infinity Gamma, Infinity Kappa, and Infinity Vista, along with SC models such as the SC 7000, SC 8000, and SC 9000XL. Four more Infinity entries, including the Infinity Delta XL and Infinity Vista XL, sit in the table under Draeger / Air Shields. XL and non-XL versions are listed separately, so match the exact model name on your unit to the Compatible Monitor Models table on the Specifications tab.


Design and Construction

Every SA-028-12 ships one per bag, and its 3.9 ft (1.2 m) cable is designed for use with Nellcor OxiSmart SpO2 technology. Because it is a reusable accessory, clean it according to your facility’s protocol after each patient and run a hand along its full length to feel for nicks or flat spots before it goes back on a monitor.


When to Replace Your SpO2 Adapter Cable

A cut or flattened jacket, strain relief pulling away from either connector, or a connector shell that is chipped or loose are all reasons to retire this adapter. On the clinical side, watch for SpO2 traces that drop out, repeated sensor alarms even though the sensor is properly applied, or numbers that jump when someone handles the cable. Substituting a second adapter that is known to work is a quick way to tell whether this cable is the problem.


Cross Reference and Interchange Part Numbers

The SA-028-12 cross-references to Draeger OEM part 3368433, the number it replaces. A single aftermarket equivalent is also on file; it sits under its own brand in the cross-reference table on the Specifications tab.


Why Source SpO2 Adapter Cables from IPR Medical?

IPR Medical buys, sells, repairs, and stocks parts for patient monitoring systems and infusion pumps, SpO2 adapter cables among them. Holding ISO 9001:2015 certification as an independent service organization, IPR Medical assigns every repair to its own in-house technicians. Call 855-477-8866, or visit our SpO2 sensors and cables category for related parts.

IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitors and SpO2 adapter cables. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Draeger, Nellcor, or any other manufacturer or supplier named on this page. Draeger, Nellcor, OxiSmart, Infinity, MultiMed, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.