IPR Medical

Spacelabs 700-0008-06 Compatible 5-Lead ECG Trunk Cable, Defib-Proof, AHA, for TruLink Leadwires, 8.2 ft (2.5 m)

$70.00

The Spacelabs 700-0008-06 compatible 5-lead ECG trunk cable (SKU ET-5007R-SL-A) is a reusable aftermarket replacement (not OEM) with limb + chest lead placement, AHA designation, a defib-proof feature, and an 8.2 ft (2.5 m) length, for use with Spacelabs TruLink leadwires.

Lead Count 5-Lead
Lead Placement Limb + Chest Lead
AHA/IEC Code AHA
Feature Defib-Proof (with Resist)
Lead Type Spacelabs TruLink
Cable Length 8.2 ft (2.5 m)
Replaces Spacelabs 700-0008-06

Works with: select Spacelabs models, including the 90496, 91390, and Qube. See the Specifications tab for the full list. Browse more ECG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for Spacelabs monitors and other patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: ET-5007R-SL-A Categories: , Tags: ,
Send In Spacelabs 700-0008-06 Compatible 5-Lead ECG Trunk Cable, Defib-Proof, AHA, for TruLink Leadwires, 8.2 ft (2.5 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) ET-5007R-SL-A
Replaces OEM Part Spacelabs 700-0008-06
Category Cables & Sensors > ECG/EKG
Product ECG Trunk Cable
Lead Count 5-Lead
Lead Placement Limb + Chest Lead
AHA/IEC Code AHA
Feature Defib-Proof (with Resist)
Lead Type Spacelabs TruLink
Cable Length 8.2 ft (2.5 m)
Intended Use Monitoring
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Spacelabs 90309, 90367, 90367 Ultraview, 90369, 90369 Ultraview, 90492, 90496, 90496 Ultraview, 91220 mCare 300, 91369, 91390, 91496, 93300, Elance Series, Qube, Ultraview SL

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Spacelabs 700-0008-06, 7271
AMC CB-61596R
Curbell CBT-05MC-10CT-0021
Sage T03-05-30M
Schiller 55.065122
Tenacore 63584
Unimed SL-2596

IPR Medical buys, sells, repairs, and stocks parts for Spacelabs patient monitors and their ECG trunk cables. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Spacelabs, or any other manufacturer or supplier named on this page. Spacelabs, TruLink, Ultraview, Elance, Qube, mCare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Spacelabs 700-0008-06 Compatible 5-Lead ECG Trunk Cable?

The IPR Medical ET-5007R-SL-A is a compatible aftermarket (not OEM) 5-lead ECG trunk cable that replaces the Spacelabs 700-0008-06. Sitting between the patient leadwires and the monitor, it is used with Spacelabs TruLink leadwires. The cable is reusable, AHA-designated, set up for limb + chest lead placement, defib-proof, and 8.2 ft (2.5 m) long, and it is intended for ECG monitoring.


Compatible Monitor Models

Spacelabs equipment accounts for the entire compatibility list on this trunk cable. It covers select Spacelabs models such as the 90367, 90496, 91220 mCare 300, 93300, and Qube, together with the Elance Series. Review the Compatible Monitor Models table on the Specifications tab for every listed model, and match it to the monitor on your unit before placing an order.


Design and Construction

The ET-5007R-SL-A is configured for five leads in a limb + chest arrangement and follows AHA designation. Its specified length is 8.2 ft (2.5 m), it carries a defib-proof feature, and it is intended for monitoring. The Lead Type row of the Specifications table reads Spacelabs TruLink, so plan to pair it with TruLink leadwires. Clean it between patients under your facility protocol and return it to service; each reusable cable ships in its own bag.


When to Replace Your 5-Lead ECG Trunk Cable

When a trunk cable fails, the problem rarely stays on a single lead. Expect traces that drop out across the display, lead-off alerts that keep returning after electrodes and leadwires have been changed, or artifact that appears each time the cable is bent or moved. A physical check should cover the full jacket for splits, cuts, and kinks, plus the monitor end for bent pins or a cracked connector housing. To separate a cable fault from a monitor fault, leave the leadwires and monitor in place and run the patient setup through a second trunk cable that is known to work.


Cross Reference and Interchange Part Numbers

Spacelabs OEM part 700-0008-06 is the reference this trunk cable replaces, and Spacelabs 7271 is also listed as a cross-reference. If your purchasing records use an aftermarket number instead, look it up on the Specifications tab, where the cross-reference table sorts each one under the brand that issued it.


Why Source ECG Trunk Cables from IPR Medical?

Trunk cables sit alongside a much wider catalog: IPR Medical buys, sells, repairs, and stocks parts for patient monitors and infusion pumps, and it holds ISO 9001:2015 certification as an independent service organization. Whatever the repair, it is completed in-house, at our own benches, by IPR Medical technicians. See our full range of ECG cables and leadwires, or call 855-477-8866 when you need a part quoted or a monitor serviced.

IPR Medical buys, sells, repairs, and stocks parts for Spacelabs patient monitors and their ECG trunk cables. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Spacelabs, or any other manufacturer or supplier named on this page. Spacelabs, TruLink, Ultraview, Elance, Qube, mCare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.