The Philips IntelliVue M3001A (Option A01C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module with Philips FAST SpO2. The C18 option combines two extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG, respiration, Philips FAST SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration. The A01C18 is the configuration of choice for cardiovascular ICUs, cardiac catheterization labs, ORs, and transport environments where diagnostic-quality 12-lead ECG and hemodynamic monitoring are required alongside the full core vital signs package. As with all M3001A C-option configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.

Part Number / Option M3001A, Option A01C18
Parameters Monitored ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Philips FAST SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)
SpO2 Technology Philips FAST SpO2 — compatible with Nellcor OxiMax sensors
12-Lead ECG Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported
IBP / Temp Port One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this port
Host Monitor Compatibility IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)
Data Storage Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

SKU: philips-intellivue-m3001a-a01c18 Categories: , Brand:
Send In Philips IntelliVue M3001A Multi-Measurement Module | Option A01C18, 12-Lead ECG, FAST SpO2, IBP & Temp for Repair

Philips IntelliVue M3001A — Specifications (Option A01C18)


Manufacturer Philips Healthcare
Model IntelliVue Multi-Measurement Module (MMS)
Part Number / Catalog Number M3001A
Option Covered by This Listing A01C18 — Philips FAST SpO2, 3/5/12-lead ECG, NBP, plus one combined Invasive Pressure/Temperature channel (the C18 option incorporates both C12 and C06 measurement packages)
Device Classification Multi-parameter Multi-Measurement Module (MMS) for use with IntelliVue host patient monitors
Intended Use Acquisition and transmission of physiological measurement data — including 12-lead ECG, arrhythmia, ST, respiration, SpO2, NBP, and invasive pressure or temperature — to a compatible IntelliVue host patient monitor. The MMS stores patient demographics, trends, and settings and supports seamless patient data transfer between compatible host monitors.
Parameters — Option A01C18 Full Package ECG (3-lead, 5-lead, and 12-lead), EASI ECG, Arrhythmia, ST Segment (up to 12-lead analysis), QT/QTc, Respiration (impedance), Philips FAST SpO2 / Pleth, Pulse Rate, NBP (oscillometric), Invasive Pressure OR Temperature (shared port)
ECG Leads 3-lead, 5-lead, and conventional 12-lead (10-electrode lead set) monitoring; EASI 12-lead derived ECG available using 5-electrode placement
12-Lead ECG Capability Conventional 12-lead ECG capture providing diagnostic signal quality as defined in the ANSI/AAMI EC11-1991 standard when used with IntelliVue host monitors; ECG data can be transmitted to and stored in compatible ECG management systems via the IntelliVue Information Center iX
EASI ECG Yes — EASI lead placement provides 12-lead ECG data using only 5 electrodes; reduces setup time and patient connection complexity
Arrhythmia Detection Yes — full arrhythmia monitoring and alarm capability via host monitor
ST Segment Analysis Yes — up to 12-lead ST segment monitoring with alarms at the bedside; ST Map visualization available via host monitor display
QT/QTc Monitoring Yes — measured QT interval, heart-rate corrected QTc value, and QTc variation tracking relative to a stored baseline
NIBP Method Oscillometric; adult, pediatric, and neonatal modes with manual, auto, and stat measurement options
SpO2 Technology Philips FAST SpO2 — compatible with the full line of Nellcor OxiMax sensors including MAX-FAST forehead sensor and non-adhesive SoftCare sensors
Invasive Pressure / Temperature — C18 Channel One combined connector (red/brown) supports either an invasive pressure transducer or a temperature probe. Per OEM service documentation, invasive pressure and temperature cannot be used simultaneously on this port — this constraint applies to both C06 and C18 configurations. To monitor both simultaneously, an MMS extension (M3012A or M3015A) is required.
Trend Storage Up to 8 hours of trend data at 1-minute resolution for all numeric parameters, stored within the MMS itself
Data Retention While Disconnected Patient demographics, trends, and active parameter settings retained in the MMS for up to 6 hours while disconnected from a host monitor
Connection to Host Monitor Direct cable-free attachment to rear of compatible IntelliVue host monitor, or via MSL (Measurement Link) cable for remote placement in patient vicinity
Host Monitor Compatibility Philips IntelliVue MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90; MX-series monitors; M3046A (M/M4 series, Release E and later)
Optional MMS Extensions M3015A (sidestream CO2 + additional press/temp); M3016A (mainstream CO2); M3012A (additional invasive pressure/temperature/CO2) — extensions add measurement channels without replacing the C18 connector
Power Source Powered by host monitor via MSL connection; no independent battery or AC power supply
Preventive Maintenance NBP calibration test required once every two years per OEM service documentation
Regulatory FDA 510(k) cleared; product code MHX (Class II); CE marked

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips or Nellcor.

Overview

The Philips IntelliVue M3001A (Option A01C18) is the most fully featured single-module configuration available in the M3001A product family. The C18 designation combines the two extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module capable of acquiring 3-, 5-, and 12-lead ECG — including EASI-derived 12-lead ECG using only 5 electrodes — full arrhythmia and ST analysis, QT/QTc monitoring, impedance respiration, Philips FAST SpO2, oscillometric NBP, and either invasive blood pressure or temperature, all within a single plug-and-play module that docks directly to any compatible IntelliVue host monitor. The A01C18 is the configuration of choice for cardiovascular ICUs, cardiac catheterization labs, ORs, and high-acuity transport environments where diagnostic-quality 12-lead ECG capture and hemodynamic or temperature monitoring are required alongside the full core vital signs package. As with all M3001A configurations, patient demographics, up to eight hours of trend data at one-minute resolution, and active measurement settings are stored in the module itself, traveling with the patient between IntelliVue host monitors and persisting for up to six hours while the module is disconnected.


12-Lead ECG — Conventional Capture and EASI

The C18 option unlocks conventional 12-lead ECG capability in the M3001A, making the A01C18 suitable for diagnostic ECG recording at the bedside alongside continuous monitoring. When used with a 10-electrode lead set connected to a compatible IntelliVue host monitor, the module provides diagnostic signal quality as defined in the ANSI/AAMI EC11-1991 standard. This is the same 12-lead capture quality used for formal diagnostic ECG interpretation, making the A01C18 appropriate for cardiac monitoring environments where documented 12-lead ECGs are part of the clinical protocol. When connected to the IntelliVue Information Center iX, 12-lead ECG data can be transmitted to and stored in a compatible ECG management system, and previously acquired ECGs can be retrieved at the bedside. The A01C18 also supports EASI ECG monitoring, which derives 12-lead ECG data using only 5 electrodes in the EASI placement configuration rather than the standard 10. EASI reduces the complexity of electrode setup, decreases the number of lead wires attached to the patient, and minimizes interference with clinical procedures — making it particularly useful in post-operative and transport environments where full 10-electrode setups are impractical. In addition, up to 12-lead ST segment analysis with alarms is available at the bedside, and QT/QTc interval monitoring tracks the measured QT interval alongside a heart-rate corrected QTc value and a QTc variation indicator referenced against a stored baseline.


The C18 Channel — Invasive Pressure or Temperature

The C18 option includes the same combined invasive pressure and temperature connector found in the C06 configuration. This single connector accepts either an invasive pressure transducer (colored red) or a temperature probe (colored brown), enabling the module to deliver arterial line pressure waveforms and numerics — systolic, diastolic, and mean — or continuous temperature monitoring depending on which device is connected. A critical operational detail confirmed in the Philips OEM service documentation is that invasive pressure and temperature cannot be used simultaneously on this connector — this constraint applies to both C06 and C18 configurations. If simultaneous pressure and temperature monitoring is required, an MMS extension module such as the M3012A or M3015A must be added to provide the additional channel. For the large majority of clinical situations in which either an arterial line or a temperature probe is active at a given time — but not both — the A01C18’s single C18 connector fully meets the need. The invasive pressure channel supports zeroing via a dedicated button on the module and is compatible with standard Philips-approved invasive pressure transducer kits and adapter cables for BD, Utah, and B. Braun connector styles.


Philips FAST SpO2 and NBP

The Philips FAST SpO2 technology in the A01C18 provides SpO2 saturation, pulse rate, and a real-time plethysmogram waveform. FAST SpO2 is compatible with the full range of Nellcor OxiMax sensors, including the MAX-FAST forehead sensor and non-adhesive SoftCare sensors, connecting directly to the module’s SpO2 port via the standard D-Connect interface without an adapter cable. Non-invasive blood pressure measurement uses the oscillometric method with adult, pediatric, and neonatal modes. Manual, automatic, and stat NBP modes are available through the host IntelliVue monitor’s interface, with each result automatically entered into the module’s trend record. The NBP pneumatic assembly requires a calibration performance check once every two years per OEM service documentation.


A01C18 vs. A01C06 and A01C12 — Understanding the Option Structure

The three C-option suffixes in the M3001A family represent distinct measurement additions to the A01 standard package. The C06 option adds the invasive pressure/temperature channel only — no 12-lead ECG. The C12 option adds conventional 12-lead ECG capability only — no invasive pressure or temperature. The C18 option combines both: 12-lead ECG and the invasive pressure/temperature channel. For facilities that require both 12-lead ECG capability and at least one hemodynamic or temperature measurement in a single MMS module, the A01C18 is the only configuration that delivers both without requiring a separate module or extension. For facilities that need only one of those additions, the A01C06 or A01C12 is the more appropriate and typically less costly selection. The invasive pressure/temperature constraint — that pressure and temperature cannot be used simultaneously on the module’s single connector — applies equally to the A01C06 and A01C18. The 12-lead ECG capability in the A01C18 is operationally identical to what is available in the A01C12.


Patient Data Portability and Trend Storage

The M3001A A01C18 stores its complete patient record internally. Up to eight hours of numeric trend data at one-minute resolution — spanning ECG-derived values, SpO2, respiration, NBP, and invasive pressure or temperature — is held within the module rather than on the host monitor. Patient demographic information, active measurement settings, and NBP calibration data are also resident in the module. When the A01C18 docks to a new IntelliVue host, this complete record uploads automatically without manual re-entry. Invasive pressure calibration and zeroing settings are preserved in the module, so the pressure channel does not need to be reconfigured when the patient is reconnected at a new bedside monitor. The module retains the full patient record for up to six hours while disconnected, supporting transport between the ICU and OR, imaging, or procedure areas without data loss. The A01C18’s 12-lead ECG capability is also preserved in the module’s settings, meaning the lead configuration and ECG display preferences travel with the patient just as all other measurement settings do.


MMS Extensions and Simultaneous Pressure and Temperature

For facilities that need simultaneous invasive pressure and temperature monitoring alongside the A01C18’s 12-lead ECG capability, MMS extension modules can supplement the single C18 connector. The M3012A Measurement Server Extension adds an additional pressure and temperature channel, enabling both the C18 connector on the M3001A and the extension’s channels to be used concurrently — in practice allowing one channel for invasive pressure and one for temperature at the same time. The M3015A extension adds sidestream CO2 capnography and an additional pressure/temperature channel. The M3016A adds mainstream CO2. These extensions attach physically to the M3001A and inherit power and network connectivity from the host monitor through the module, requiring no separate power supplies or additional MSL cables.


Host Monitor Connectivity and System Integration

The M3001A A01C18 connects to compatible IntelliVue host monitors in either the direct-dock configuration — locking to the rear of the host monitor without cables — or the remote configuration via MSL cable for placement in the patient vicinity. Once connected, all monitoring, alarm, and configuration functions are managed through the host monitor’s interface. The A01C18 is compatible with the full IntelliVue MP-series platform (MP20 through MP90), the MX-series monitors, and the M3046A (M/M4 series) running Release E or higher software. When the host monitor is networked to the IntelliVue Information Center, all measurement data from the A01C18 — including 12-lead ECG captures, invasive pressure waveforms, and temperature — flows transparently for central monitoring, trend archiving, ECG storage, and clinical reporting.


IPR Medical — Buy, Sell, Repair, and Parts

IPR Medical is a secondary market specialist for Philips IntelliVue patient monitoring equipment, including the M3001A across all option configurations. For the M3001A A01C18 specifically, IPR Medical purchases units in various conditions, sells tested and refurbished modules, and provides repair services for component-level issues including the NBP pneumatic assembly, FAST SpO2 circuitry, invasive pressure and temperature interface, ECG acquisition hardware, and MSL connectivity. IPR Medical also stocks commonly requested accessories for the A01C18, including 10-lead ECG trunk cables and leadsets for 12-lead capture, 5-lead cables for standard and EASI monitoring, Philips FAST SpO2 sensors, NIBP cuffs and hoses, IBP adapter cables, temperature probes, and MSL cables. Contact our team to confirm current availability, discuss configuration requirements, or request a service assessment.

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips or Nellcor.

Weight 1 lbs
Dimensions 8 × 6 × 4 in

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the Philips IntelliVue M3001A (Option A01C18). The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.


MMS Extension Modules

M3012A Hemodynamic/Pressure/Temperature MMS Extension — adds an additional invasive pressure channel and temperature channel, enabling simultaneous use of pressure and temperature when combined with the A01C18’s shared connector
M3015A Sidestream CO2 Measurement Server Extension — attaches to the M3001A to add sidestream capnography plus an additional pressure/temperature channel; powered via host monitor MSL connection
M3016A Mainstream CO2 Measurement Server Extension — attaches to the M3001A to add mainstream capnography; powered via host monitor MSL connection

ECG Cables and Leadsets — 12-Lead

M1665A 10-lead trunk cable (12-pin connector) — for conventional 12-lead ECG capture on the M3001A A01C18; pair with one chest leadset and one limb leadset for full 10-electrode application
M1663A / M1949A Alternative 10-lead trunk cables (12-pin connector) — compatible with M3001A C12/C18 for 12-lead ECG applications; contact IPR Medical to confirm availability
Chest leadsets (AAMI) Precordial chest leadsets for use with 10-lead trunk cables on M3001A A01C18 — contact IPR Medical to confirm specific part numbers available
Limb leadsets (AAMI) Limb leadsets for use with 10-lead trunk cables on M3001A A01C18 — contact IPR Medical to confirm specific part numbers available

ECG Cables and Leadsets — 3-Lead and 5-Lead / EASI

M1668A 5-lead ECG trunk cable (12-pin connector) — for 5-lead monitoring and EASI ECG configurations on the M3001A A01C18; also accepts 3-lead sets
M1667A 6-lead trunk cable (12-pin connector) — for 6-lead and EASI ECG monitoring on the M3001A A01C18; also accepts 3-lead and 5-lead sets
M1669A 3-lead ECG trunk cable — compatible with M3001A for 3-lead monitoring configurations
M1977A 5-lead ECG set, direct-connect pinch/grabber leadwires — for use with M3001A compatible trunk cables (AAMI color coding)

SpO2 Sensors and Cables

M1191A Philips SpO2 soft-shell adult finger sensor, 3 ft, direct D-Connect — compatible with M3001A Option A01C18 FAST SpO2 port
M1191AL Philips SpO2 soft-shell adult finger sensor, 10 ft, direct D-Connect — extended cable version
M1192A Philips SpO2 soft-shell pediatric sensor, 3 ft, D-Connect
M1194A Philips SpO2 ear clip sensor, D-Connect, 3 ft
M1196A Philips SpO2 hard-shell adult patient sensor, D-Connect, 1.5 m — reusable hard-shell option
M1941A Philips SpO2 extension cable, 7 ft, D-Connect to D-Connect

Invasive Pressure Accessories

684081 Philips IBP adapter cable — male 12-pin, 13 ft — to BD connector style; for use with the M3001A A01C18 invasive pressure port
650-206 Philips IBP adapter cable — male 12-pin, 13 ft — to Utah connector style; for use with the M3001A A01C18 invasive pressure port
M1634A Philips IBP adapter cable — male 12-pin, 13 ft — to B. Braun connector style; for use with the M3001A A01C18 invasive pressure port
Disposable pressure transducer kits Single-use invasive pressure transducer kits compatible with the M3001A C18 pressure channel — contact IPR Medical to confirm compatible transducer brands and part numbers for your facility’s protocol

Temperature Probes

M21078A Philips adult reusable skin temperature sensor — round 2-pin connector, 9 ft; compatible with M3001A A01C18 temperature port
21075A Philips adult reusable rectal temperature sensor — round 2-pin connector, 9 ft; compatible with M3001A A01C18 temperature port
21082A Philips temperature probe adapter — female mono plug to rectangular 2-pin connector, 9 ft; for use with M3001A A01C18 temperature port
DHP-30-AD0 Philips temperature adapter — rectangular plug to rectangular 2-pin connector, 9 ft; for use with M3001A A01C18 temperature port
DHP-AD0 Philips temperature adapter — female mono plug to round 2-pin connector, 1 ft; for use with M3001A A01C18 temperature port

NIBP Cuffs and Hoses

M1599B Philips NIBP single hose, male-to-female metal connector — replacement NBP hose compatible with M3001A
M3918A Philips NIBP single hose — replacement NBP hose compatible with M3001A
Adult NIBP cuffs Single-patient and reusable adult NBP cuffs compatible with the M3001A NBP hose connection — contact IPR Medical to confirm sizing and part number availability
Pediatric / neonatal NIBP cuffs Pediatric and neonatal cuff sizes compatible with the M3001A — contact IPR Medical to confirm current availability

Cables and Connectivity

MSL cable Measurement Link cable — connects the M3001A to the host IntelliVue monitor when the module is not directly docked; carries power, data, and network communication

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Reviews