Philips IntelliVue M3012A Hemodynamic Extension | Option C00, Dual Pressure & Dual Temperature
The Philips IntelliVue M3012A (Option C00) is the base configuration of the IntelliVue Hemodynamic Measurement Server Extension. It attaches directly to the Philips M3001A Multi-Measurement Module to add two independent invasive pressure channels, two independent temperature channels, and one combined pressure/temperature connector — enabling simultaneous hemodynamic pressure and temperature monitoring that the M3001A’s single shared C06 or C18 connector cannot provide on its own. The M3012A C00 is the standard hemodynamic expansion unit for ICU, cardiovascular step-down, and critical care transport environments where multiple pressure lines, bilateral temperature monitoring, or both are required alongside the M3001A’s core vital signs parameter set, but cardiac output measurement is not part of the clinical protocol.
IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3012A. Contact us at 855-477-8866 or cs@iprmed.com.
Philips IntelliVue M3012A — Specifications (Option C00)
| Manufacturer | Philips Healthcare |
| Model | IntelliVue M3012A Hemodynamic Measurement Server Extension |
| Option Covered by This Listing | C00 — Dual Invasive Pressure, Dual Temperature, combined Pressure/Temperature channel; no cardiac output |
| Device Classification | Hemodynamic Measurement Server Extension for use with the Philips IntelliVue M3001A Multi-Measurement Module |
| Intended Use | Extension of hemodynamic measurement capability beyond the M3001A’s standard channels; adds dual invasive pressure and dual temperature channels to the M3001A + IntelliVue host monitor monitoring system |
| Parameters — Option C00 | Invasive Pressure (2 independent channels), Temperature (2 independent channels), combined Pressure/Temperature (1 shared connector) |
| Invasive Pressure Channels | 2 independent invasive pressure channels; supports simultaneous monitoring of two hemodynamic pressure lines (e.g., arterial and CVP, or two arterial lines); waveform labeling, scale, and zeroing managed via host IntelliVue monitor |
| Temperature Channels | 2 independent temperature channels; supports simultaneous monitoring from two probe sites; probe type selected at the host monitor |
| Combined Pressure/Temperature Channel | 1 additional shared connector accepting either an invasive pressure transducer or a temperature probe; pressure and temperature cannot be used simultaneously on this connector |
| Cardiac Output | Not included in Option C00. Bolus cardiac output available with Option C05; bolus + continuous cardiac output available with Option C10. |
| Host Module Requirement | Attaches directly to the Philips IntelliVue M3001A Multi-Measurement Module (all option configurations); the M3012A requires the M3001A for host monitor connectivity and power — it cannot connect to an IntelliVue monitor independently |
| Host Monitor Compatibility | Via M3001A: Philips IntelliVue MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90; MX-series monitors; M3046A (M/M4 series, Release E and later) |
| Power Source | Powered via M3001A connection to host monitor MSL; no independent battery or AC power supply required |
| Data Storage | Up to 8 hours of patient trend data; calibration and measurement settings retained during transport |
| Weight | 0.99 lb (450 g) |
| Dimensions (H x W x D) | 7.8 x 3.8 x 3.5 in (200 x 97 x 90 mm) |
| Operating Temperature | 32–104°F (0–40°C) |
| Storage Temperature | -4–140°F (-20–60°C) |
| Operating Humidity | 15–95% RH non-condensing |
| Operating Altitude | -1,640 to +9,842 ft (-500 to +3,000 m) |
| Ingress Protection | IP32 (when in horizontal position) |
| Regulatory | FDA 510(k) cleared; CE marked |
IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3012A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.
Overview
The Philips IntelliVue M3012A (Option C00) is the base hemodynamic configuration of the IntelliVue Measurement Server Extension. It attaches directly to the top of the M3001A Multi-Measurement Module to add two independent invasive pressure channels, two independent temperature channels, and one combined pressure/temperature connector — the full hemodynamic channel set without cardiac output capability. The C00 is the appropriate selection for ICU and critical care environments where the clinical workflow requires simultaneous arterial and hemodynamic pressure monitoring alongside temperature, but formal cardiac output measurement via pulmonary artery catheter is not indicated for the patient population in that care area. It resolves the fundamental constraint of the M3001A’s single shared C06 or C18 connector, which can support either pressure or temperature at a given time but not both simultaneously. With the M3012A C00 attached, the combined M3001A + M3012A assembly can support arterial line pressure on one channel, CVP or PA pressure on another, and continuous temperature monitoring from one or two probe sites — all running concurrently alongside the M3001A’s core ECG, SpO2, NBP, and respiration parameters. The assembly stores up to eight hours of trend data and all calibration settings internally, traveling with the patient during transport and uploading automatically when connected to a new IntelliVue host monitor.
Dual Invasive Pressure Channels
The M3012A C00 provides two fully independent invasive pressure channels. Each channel delivers a continuous pressure waveform and systolic, diastolic, and mean numeric values, with waveform labeling, scale settings, alarm thresholds, and zeroing all managed through the host IntelliVue monitor’s interface. The two channels operate simultaneously and independently, making the C00 appropriate for patients requiring two active pressure lines at the same time. Common clinical configurations include arterial pressure on one channel and central venous pressure on the other, or bilateral arterial monitoring, or arterial and pulmonary artery pressure. Each channel connects to a compatible invasive pressure transducer via Philips-approved IBP adapter cables in BD, Utah, and B. Braun connector styles. Zeroing settings for both pressure channels are stored in the M3012A and preserved during patient transport, meaning the clinical team does not need to re-zero pressure lines when the patient arrives at a new IntelliVue host monitor.
Dual Temperature Channels and Combined Pressure/Temperature Connector
The M3012A C00 also provides two fully independent temperature channels, each accepting a compatible temperature probe and displaying continuous temperature numeric values through the host IntelliVue monitor. The two independent channels allow simultaneous monitoring from two separate probe sites — for example, esophageal and skin temperature, or two core temperature locations — when bilateral temperature tracking is clinically indicated. In addition to the two dedicated temperature channels, the M3012A includes one combined pressure/temperature connector that follows the same shared-connector design as the M3001A’s C06 port. This connector accepts either an invasive pressure transducer or a temperature probe, but pressure and temperature cannot be used simultaneously on this single shared connector. In most clinical configurations, this combined connector provides a third available connection point for whichever measurement type is needed, used in combination with the two independent channels on each side.
C00 vs. C05 and C10 — Selecting the Right Option
The M3012A C00 is the right configuration for care areas where invasive hemodynamic pressure monitoring and temperature measurement are routine, but cardiac output measurement via pulmonary artery catheter is not. General medical and surgical ICUs, cardiovascular step-down units, and high-acuity transport environments where PA catheters are rarely or never used will find the C00 provides everything needed without the additional complexity and cost of the cardiac output options. For cardiac surgical ICUs, hemodynamic instability cases, or any environment where PA catheters and formal cardiac output measurement are standard practice, Option C05 adds bolus thermodilution cardiac output to the same dual pressure and temperature channel set. Option C10 extends further to include continuous cardiac output for patients requiring real-time trending rather than periodic spot measurements. From a secondary market perspective, C05 and C10 units carry additional cardiac output circuitry that is not present in C00 units, which is relevant when evaluating parts sourcing and repair scope for a given unit.
Why the M3012A C00 — Resolving the M3001A Single-Channel Constraint
Every M3001A variant with a C06 or C18 option provides a single shared connector that accepts either an invasive pressure transducer or a temperature probe — but not both at the same time. This is confirmed in Philips OEM service documentation and applies to all C06 and C18 configurations regardless of the A-option SpO2 variant. For patients who require both an active arterial line and a temperature probe simultaneously, the M3001A alone cannot meet that need. The M3012A C00 is the OEM-defined solution — attaching directly to any M3001A, it provides the dedicated independent channels needed to run pressure and temperature at the same time. For M3001A standard or C12 configurations that have no pressure or temperature connector at all, the M3012A C00 provides the entire hemodynamic channel set from scratch. This universal compatibility across all M3001A option configurations makes the M3012A C00 a standard hemodynamic expansion unit applicable to every M3001A deployment scenario.
Transport and Data Portability
The M3012A C00 + M3001A combined assembly is designed for patient transport. The M3012A stores patient demographics, calibration data for all active pressure and temperature channels, and up to eight hours of trend data within the unit. When the assembly connects to a new IntelliVue host monitor, this complete record uploads automatically without manual re-entry, and pressure channel zeroing settings are preserved — the clinical team does not need to reconfigure or re-zero the pressure lines after a monitor swap or room transfer. The combined assembly can travel with a portable IntelliVue monitor connected via MSL or be held in hand during short transport episodes. The M3012A weighs 0.99 lb (450 g) and measures 7.8 x 3.8 x 3.5 inches — compact enough to maintain a manageable overall assembly size when stacked with the M3001A.
Host Monitor Connectivity and System Integration
The M3012A C00 receives power and communicates with the IntelliVue host monitor entirely through its attachment to the M3001A. No additional MSL cable or separate power supply is required. The combined M3001A + M3012A assembly connects to any compatible IntelliVue host monitor — MP20 through MP90, MX-series monitors, and the M3046A (M/M4 series, Release E and later) — in either the direct-dock or remote MSL-cable configuration. All measurement data from the M3012A, including pressure waveforms, temperature numerics, and derived values, flows to the host monitor for display, alarming, and trend storage alongside the M3001A’s core parameters. When the host monitor is networked to the IntelliVue Information Center, hemodynamic data from the M3012A is included in the central monitoring feed, trend archives, and clinical documentation without any additional configuration.
IPR Medical — Buy, Sell, Repair, and Parts
IPR Medical is a secondary market specialist for Philips IntelliVue patient monitoring equipment, including the M3012A across all option configurations. For the M3012A C00 specifically, IPR Medical purchases units in various conditions, sells tested and refurbished extensions, and provides repair services for component-level issues including invasive pressure interface circuitry, temperature channel hardware, and MSL connectivity. Because the C00 does not include cardiac output circuitry, repair scope is narrower and internal component sourcing is more straightforward than for C05 or C10 units. IPR Medical also stocks commonly requested accessories for the M3012A C00, including IBP adapter cables in BD, Utah, and B. Braun connector styles, disposable pressure transducer kits, and temperature probes. Contact our team to confirm current availability or to request a service assessment for your M3012A fleet.
IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3012A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 6 × 4 in |
Compatible Parts and Accessories
IPR Medical stocks a range of compatible parts and accessories for the Philips IntelliVue M3012A (Option C00). The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.
Host Module (Required for M3012A Operation)
| Philips M3001A (all options) | The M3012A C00 attaches to and requires the M3001A Multi-Measurement Module as its host; compatible with all M3001A option configurations (A01 through A04C18); contact IPR Medical to confirm availability of specific M3001A option configurations |
Invasive Pressure Accessories
| 684081 | Philips IBP adapter cable — male 12-pin, 13 ft — to BD connector style; for use with M3012A C00 invasive pressure ports |
| 650-206 | Philips IBP adapter cable — male 12-pin, 13 ft — to Utah connector style; for use with M3012A C00 invasive pressure ports |
| M1634A | Philips IBP adapter cable — male 12-pin, 13 ft — to B. Braun connector style; for use with M3012A C00 invasive pressure ports |
| Disposable pressure transducer kits | Single-use invasive pressure transducer kits compatible with M3012A C00 pressure channels — contact IPR Medical to confirm compatible transducer brands and part numbers for your facility’s protocol |
Temperature Probes
| M21078A | Philips adult reusable skin temperature sensor — round 2-pin connector, 9 ft; compatible with M3012A C00 temperature ports |
| 21075A | Philips adult reusable rectal temperature sensor — round 2-pin connector, 9 ft; compatible with M3012A C00 temperature ports |
| 21082A | Philips temperature probe adapter — female mono plug to rectangular 2-pin connector, 9 ft; for use with M3012A C00 temperature ports |
| DHP-30-AD0 | Philips temperature adapter — rectangular plug to rectangular 2-pin connector, 9 ft; for use with M3012A C00 temperature ports |
| DHP-AD0 | Philips temperature adapter — female mono plug to round 2-pin connector, 1 ft; for use with M3012A C00 temperature ports |
Cables and Connectivity
| MSL cable | Measurement Link cable — connects the M3001A (with attached M3012A C00) to the host IntelliVue monitor when the assembly is not directly docked; carries power, data, and network communication for both the M3001A and M3012A |
IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3012A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.