IPR Medical

Compatible aftermarket ECG, SpO2, NIBP, IBP, temperature and fetal cables and sensors from Orantech, offered by IPR Medical. These are not original manufacturer (OEM) products; brand names shown on individual listings identify the equipment each cable or sensor is designed to work with.

  • Masimo Compatible SpO2 Adapter Cable LNCS>Nellcor (SA-005RB-03)

    $50.00

    The Masimo compatible SpO2 adapter cable, LNCS to Nellcor (SKU SA-005RB-03) is a reusable, aftermarket replacement (not OEM) adapter that allows Nellcor-style SpO2 sensors to be used on monitors and pulse oximeters equipped with Masimo LNCS technology.

    Cable Type
    SpO2 Adapter Cable

    Function
    Adapts Nellcor-style SpO2 sensors to Masimo LNCS-equipped monitors and pulse oximeters

    Cable Length
    1 ft (0.3 m)

    Lifecycle
    Reusable

    Unit of Measure
    1 each

    Works with: select Masimo LNCS-equipped monitors and pulse oximeters from Masimo, GE Healthcare, Mindray, Physio-Control, Welch Allyn, Zoll, and others. See the Specifications tab for the full list. Browse our full selection of SpO2 sensors and cables.

    IPR Medical buys, sells, repairs, and stocks parts for the patient monitors and pulse oximeters this adapter supports. Call 855-477-8866 or email cs@iprmed.com.

  • YSI 401 Compatible Adult General (Oral/Rectal) Temperature Probe, 400 Series, 0.16 in (4.0 mm) Tip, 9.8 ft (3.0 m)

    $45.00

    The YSI 401 compatible adult general (oral/rectal) temperature probe (SKU TS-Y400-AG30) is a reusable aftermarket replacement (not OEM) with a 0.16 in (4.0 mm) probe tip and a 9.8 ft (3.0 m) cable, for use with 400 Series temperature technology.

    Patient Size
    Adult

    Probe Type
    General (Oral/Rectal)

    Probe Tip
    0.16 in (4.0 mm)

    Temperature Technology
    400 Series

    Cable Length
    9.8 ft (3.0 m)

    Replaces
    YSI 401

    Works with: select Nihon Kohden, Edan, Criticare / CSI, and Welch Allyn models, plus other brands. See the Specifications tab for the full list. Browse more temperature probes and cables.

    IPR Medical buys, sells, repairs, and stocks parts for patient monitors and reusable temperature probes. Call 855-477-8866 or email cs@iprmed.com.

  • Nellcor D-YS Compatible Multi-Y SpO2 Sensor, All Sizes, OxiMax, 3.3 ft (1.0 m)

    $70.00

    The Nellcor D-YS compatible Multi-Y SpO2 sensor (SKU SS-001XC-MY10) is a reusable aftermarket replacement (not OEM) for all patient sizes, with a 3.3 ft (1.0 m) cable, for use with Nellcor OxiMax technology.

    Sensor Type
    Multi-Y

    Patient Size
    All Sizes

    SpO2 Technology
    Nellcor OxiMax

    Cable Length
    3.3 ft (1.0 m)

    Lifecycle
    Reusable

    Replaces
    Nellcor D-YS

    Works with: select Nellcor, GE Healthcare, Mindray / Datascope, Welch Allyn, and Nihon Kohden models, plus other brands. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.

    IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • Critikon/GE Compatible NIBP Cuff, Adult 23–33 cm, Two-Tube Screw | 2464

    $17.50

    The GE Healthcare / Critikon 2464 compatible adult NIBP cuff is a reusable, aftermarket replacement (not OEM) two-tube blood pressure cuff with an integrated bladder and screw connectors that mate with GE, Critikon, and Dinamap screw-type NIBP hose connections.

    Patient Size
    Adult

    Limb Circumference
    23–33 cm

    Tube Configuration
    Two-Tube (Double Tube)

    Bladder
    Integrated

    Connector Type
    Two-Tube Screw

    Lifecycle
    Reusable

    Replaces
    GE Healthcare / Critikon 2464

    Works with: GE Healthcare, Critikon, and Dinamap NIBP systems that use two-tube screw-type hose connections.

    IPR Medical buys, sells, repairs, and stocks parts for GE Healthcare, Critikon, and Dinamap patient monitoring systems. Call 855-477-8866 or email cs@iprmed.com.

  • Draeger MS17522 Compatible SpO2 Adapter Cable, for Use with Masimo LNCS Sensors, 7.9 ft (2.4 m)

    $60.00

    The Draeger MS17522 compatible SpO2 adapter cable (SKU SA-028RB-24LS) is a reusable aftermarket replacement (not OEM) with a 7.9 ft (2.4 m) cable, for use with Masimo LNCS sensors.

    Cable Type
    SpO2 Adapter Cable

    SpO2 Technology
    Masimo LNCS

    Cable Length
    7.9 ft (2.4 m)

    Lifecycle
    Reusable

    Packaging
    1 per bag

    Replaces
    Draeger MS17522

    Works with: select Draeger Infinity models such as the Infinity Gamma and Infinity MultiMed Pod. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.

    IPR Medical buys, sells, repairs, and stocks parts for Draeger monitors and the SpO2 cables that connect to them. Call 855-477-8866 or email cs@iprmed.com.

  • Mindray 115-020768-00 Compatible SpO2 Adapter Cable for Masimo LNCS Sensors, 7.9 ft (2.4 m)

    $60.00

    The Mindray 115-020768-00 compatible SpO2 adapter cable is a reusable, aftermarket replacement (not OEM) for the Mindray/Datascope Masimo SpO2 extension cable, built to match the original’s fit, form, and function. It connects Masimo LNCS pulse oximetry sensors to Mindray and Datascope monitors equipped with Masimo SpO2.

    SpO2 Technology
    Masimo LNCS

    Monitor-End Connector
    Male 8-Pin Round, Keyed

    Sensor-End Connector
    Female 9-Pin D-Sub (LNCS)

    Cable Length
    7.9 ft (2.4 m)

    Construction
    Reusable, Latex-Free

    Works with: Masimo-equipped Mindray BeneVision N-Series, BeneView T-Series, Passport 8/12/12m/17m, iPM and iMEC Series, ePM Series, BeneHeart D-Series, Accutorr 3 and 7, and Datascope DPM, MPM, and PM 6800 monitors. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.

    IPR Medical buys, sells, repairs, and stocks parts for Mindray and Datascope patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • GE Healthcare 2017008-001 Compatible Dual-Tube NIBP Air Hose, Adult/Pediatric, 12 ft (3.6 m)

    $50.00

    The GE Healthcare 2017008-001 compatible NIBP air hose is a reusable, aftermarket replacement (not OEM) for GE’s dual-tube adult/pediatric blood pressure hose, built to match the original’s fit, form, and function.

    Hose Type
    Dual-Tube

    Monitor-End Connector
    GE Adult Black Block

    Cuff-End Connectors
    Dual Twist-Lock (for Female Cuff Fittings)

    Hose Length
    12 ft (3.6 m)

    Patient Size
    Adult/Pediatric

    Construction
    PVC, Reusable, Latex-Free

    Works with: GE Dash 2000–5000, CARESCAPE B450/B650/B850, Solar, Tram, Corometrics 120/250/259 series, Datex-Ohmeda Aespire 7900, and more. See the Specifications tab for the full list. Browse more NIBP hoses and accessories.

    IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • Mindray 0010-30-42625 Compatible SpO2 Adapter Cable for Masimo LNCS Sensors, 6-Pin, 7.9 ft

    $50.00

    The Mindray 0010-30-42625 compatible SpO2 adapter cable (SKU SA-052M-24LS) is a reusable, aftermarket replacement (not OEM). It connects Masimo LNCS-compatible SpO2 sensors to the compatible Mindray and Datascope monitors listed below.

    Cable Type
    SpO2 Adapter (Extension) Cable, Reusable

    SpO2 Technology
    Masimo LNCS Compatible

    Monitor Connector
    6-Pin

    Cable Length
    7.9 ft (2.4 m)

    Replaces
    Mindray 0010-30-42625, 115-023136-00

    Works with: Datascope DPM3, DPM4, DPM5, M1K0, M2K0 (before January 2006), PM 6201, PM 8000 Express, PM 9000 Express, PM 9100, PM 9200P, and VS 800, plus Mindray PM 6000, PM 7000, PM 8000, and PM 9000 monitors. See the Specifications tab for the full list, including models that require the Masimo SpO2 option. Browse more SpO2 sensors and adapter cables.

    IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • Philips M1599B Compatible Adult/Pediatric NIBP Air Hose, 1-Tube, 6.0 mm Male Plug, 9.8 ft (3.0 m)

    $36.00

    The M1599B compatible NIBP air hose (SKU BPH-AS30-07Z-02M) is a reusable aftermarket replacement (not OEM) with a 6.0 mm male BP plug and a 9.8 ft (3.0 m) single-tube design, for use with a 1-tube bayonet cuff on adult and pediatric patients.

    Patient Size
    Adult/Pediatric

    Tube Configuration
    1-Tube (Single Tube)

    BP Plug
    6.0 mm Male

    Used with Cuff
    1-Tube Bayonet Cuff

    Hose Length
    9.8 ft (3.0 m)

    Replaces
    Philips M1599B

    Works with: the monitor models listed in the Specifications tab. Browse more NIBP hoses and accessories.

    IPR Medical buys, sells, repairs, and stocks parts for blood pressure accessories and patient monitors. Call 855-477-8866 or email cs@iprmed.com.

  • AAMI Compatible One-Piece ECG Cable, 3-Lead Snap, AHA | EC-3001S-A

    $50.00

    The AAMI-compatible one-piece 3-lead ECG cable (SKU EC-3001S-A) is a reusable aftermarket replacement (not OEM) that combines the trunk and leadwires into a single integrated assembly for direct connection to AAMI-standard patient monitors and defibrillators.

    Cable Construction
    One-Piece (Integrated Trunk and Leadwires)

    Lead Count
    3-Lead

    Electrode End
    Snap

    Color Code
    AHA

    Monitor Connection
    AAMI Standard

    Cable Length
    Approx. 11 ft (3.4 m)

    Lifecycle
    Reusable

    Replaces
    Edan 01.57.471095-10; Zoll 8000-0025-02; Mindray 009-005268-00

    Works with: AAMI-standard patient monitors and defibrillators, including select Edan, Zoll, Medtronic/Physio-Control Lifepak, Mindray/Datascope, Nihon Kohden, Spacelabs, and Criticare models. See the Specifications tab for the full list.

    IPR Medical buys, sells, repairs, and stocks parts for patient monitoring systems. Call 855-477-8866 or email cs@iprmed.com.

  • AAMI Compatible One-Piece ECG Cable, 5-Lead Snap, AHA | EC-5001S-A

    $60.00

    The AAMI compatible one-piece 5-lead ECG cable (SKU EC-5001S-A) is a reusable, aftermarket replacement (not OEM) that connects directly to AAMI-standard patient monitors and defibrillators, combining the trunk and leadwires into a single integrated assembly for fewer connection points and a cleaner bedside setup.

    Cable Construction
    One-Piece (Integrated Trunk and Leadwires)

    Lead Count
    5-Lead

    Electrode End
    Snap

    Color Code
    AHA

    Monitor Connection
    AAMI Standard

    Approx. Cable Length
    Trunk ~8 ft (2.4 m), leadwires ~3 ft (0.9 m)

    Lifecycle
    Reusable

    Replaces
    Zoll 8000-1005-01

    Works with: select AAMI-standard monitors and defibrillators from Zoll (M, E, and R Series), Physio-Control (Lifepak 5 through 10), Mindray / Datascope, Nihon Kohden, Spacelabs, Criticare, Invivo, and other manufacturers. See the Specifications tab for the full list.

    IPR Medical buys, sells, repairs, and stocks parts for patient monitoring systems. Call 855-477-8866 or email cs@iprmed.com.

  • Masimo 4050 (RD SET DCI) Compatible Adult Finger Clip SpO2 Sensor, Reusable, 3.3 ft (1.0 m)

    $96.00

    The Masimo 4050 (RD SET DCI) compatible SpO2 sensor (SKU SS-165RB-AF10) is a reusable, aftermarket replacement (not OEM) adult finger clip sensor for Masimo RD SET-equipped monitors, built to match the original’s fit, form, and function.

    Sensor Type
    Hard Shell Finger Clip

    Patient Size
    Adult, >66 lbs (>30 kg)

    Connector
    Masimo RD SET

    Cable Length
    3.3 ft (1.0 m)

    Lifecycle
    Reusable

    Replaces
    Masimo 4050, Physio-Control 11996-000456, Zoll 8000-001814, Mindray 040-003376-00, and more

    Works with: Masimo RD SET-equipped Mindray Accutorr 3, Accutorr 7, cPM 8, cPM 12, ePM 10M, and ePM 12M monitors, and Digicare LifeWindow 9X, LifeWindow Lite LW8, and LifeWindow One. Requires an RD SET patient cable. Browse more SpO2 cables and sensors.

    IPR Medical buys, sells, repairs, and stocks parts for Masimo patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.