YSI 401 Compatible Adult General (Oral/Rectal) Temperature Probe, 400 Series, 0.16 in (4.0 mm) Tip, 9.8 ft (3.0 m)
The YSI 401 compatible adult general (oral/rectal) temperature probe (SKU TS-Y400-AG30) is a reusable aftermarket replacement (not OEM) with a 0.16 in (4.0 mm) probe tip and a 9.8 ft (3.0 m) cable, for use with 400 Series temperature technology.
| Patient Size | Adult |
| Probe Type | General (Oral/Rectal) |
| Probe Tip | 0.16 in (4.0 mm) |
| Temperature Technology | 400 Series |
| Cable Length | 9.8 ft (3.0 m) |
| Replaces | YSI 401 |
Works with: select Nihon Kohden, Edan, Criticare / CSI, and Welch Allyn models, plus other brands. See the Specifications tab for the full list. Browse more temperature probes and cables.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and reusable temperature probes. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | TS-Y400-AG30 |
| Replaces OEM Part | YSI 401 |
| Category | Cables & Sensors > Temperature |
| Product | Temperature Probe |
| Patient Size | Adult |
| Probe Type | General (Oral/Rectal) |
| Probe Tip | 0.16 in (4.0 mm) |
| Temperature Technology | 400 Series |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Biolight | M9500 |
| Bionet | BM3, BM3Vet, BM5Vet Pro |
| Cardell | 9401, 9402, 9403, 9404, 9405, 9454 (Vet), 9456 (Vet), 9500HD, Touch |
| Carewell | CPM-9000T |
| CASMed | 750 |
| Contec | CMS 6800, CMS 8000, CMS 9000, Patient Simulator MS400 |
| Criticare / CSI | 506, 507, 507E, 507EL(Scholar III), 507ELC, 507ELC2, 507EP, 507ER, 507S, 507SD, 508, 1100, 2200, 2200(Scholar EL), 8100, 8100 (Poet Plus), 8100E Series (nGenuity), 8100H Series (nCompass) |
| Datex-Ohmeda | Cardiocap I, Cardiocap II, Cardiocap/5, CS/3, Light Monitor, M-ESTP, S/3, S/5, Satliteplus |
| Draeger | Infinity Delta, Infinity Gamma, Infinity Kappa, Infinity Vista, Narkomed 6400 |
| DRE | Waveline EZ MAX |
| Edan | F9, F9 Express, iM8, iM8 VET, iM8A, iM8B, iM9, iM9A, iM50, iM60, iM60 VET, iM70, iM70 VET, iM80, iM80 VET, iM80 with Nellcor OxiMax technology, iM80 without Nellcor OxiMax technology, M3, M3A, M3B, M8A, M8B, M9, M9A, M50, M80 |
| Fukuda Denshi | Dynascope DS-7100 |
| GE Healthcare / Critikon Dinamap | B125 |
| GE Healthcare / Marquette | Procare B40 |
| Gentherm / Cincinnati Sub-Zero | Blanketrol II, Blanketrol III |
| Invivo | M8, MDE Prism |
| Mediana | M20 |
| MEK | MP 100, MP 110, MP 400, MP 500, MP 600, MP 700, MP 1000, MP 7000 |
| Mennen | VitaLogik 4000, VitaLogik 6000 |
| Mindray / Datascope | DPM 5, Expert, MEC 1000, MEC 1200, MEC 2000, Passport 2, Passport 2LT, Passport 5L, Passport 8, Passport 12, Passport 12m, Passport 17m, Passport EL, Passport XG, PM 5000, PM 6000, PM 7000, PM 7000Standard, PM 8000, PM 8000Express, PM 9000, PM 9000 Express, PM-9000Vet, Spectrum OR, Trio, VS 800 |
| Nihon Kohden | BSM-73, BSM-73C, BSM-1101, BSM-1101K, BSM-1102, BSM-1102K, BSM-1700 Series, BSM-2000, BSM-2101, BSM-2102, BSM-2300, BSM-2300 Life Scope I, BSM-2300 Series, BSM-2300 with YJ 230P, BSM-2300C, BSM-2301, BSM-2301C, BSM-2303, BSM-2303C, BSM-2304, BSM-2351, BSM-2351C, BSM-2353, BSM-2353C, BSM-2354A, BSM-3000, BSM-3000 Series, BSM-3000 with AY 631P, BSM-3000 with AY 633P, BSM-3000 with AY 651P, BSM-3000 with AY 653P, BSM-3101, BSM-3500, BSM-3532, BSM-3552, BSM-3562, BSM-3700, BSM-3733, BSM-3753, BSM-3763, BSM-4100, BSM-4100 Life Scope P, BSM-4100 Series, BSM-4101, BSM-4101K, BSM-4102, BSM-4103, BSM-4103K, BSM-4104, BSM-4111, BSM-4111K, BSM-4112, BSM-4113, BSM-4113K, BSM-4114, BSM-5000 Series, BSM-5100, BSM-5100 Life Scope A, BSM-5100 Series, BSM-5100 with YJ 510P, BSM-5105, BSM-5105K, BSM-5135, BSM-5135K, BSM-6000 Series, BSM-6000 with AY 631P, BSM-6000 with AY 633P, BSM-6000 with AY 651P, BSM-6000 with AY 653P, BSM-6301, BSM-6301C, BSM-6311, BSM-6312, BSM-6313, BSM-6331, BSM-6332, BSM-6333, BSM-6501, BSM-6501C, BSM-6531, BSM-6532, BSM-6533, BSM-6571, BSM-6572, BSM-6573, BSM-6701, BSM-6701A, BSM-6701C, BSM-6731, BSM-6732, BSM-6733, BSM-6771, BSM-6772, BSM-6773, BSM-7100, BSM-7102A, BSM-7200, BSM-7201K, BSM-7211K, BSM-8200, BSM-8201, BSM-8300, BSM-8301, BSM-8301A, BSM-8302, BSM-8302A, BSM-8500, BSM-8500A, BSM-8502, BSM-8502A, BSM-8800, BSM-8800A, BSM-9100, BSM-9100 with AY 631P, BSM-9100 with AY 633P, BSM-9100 with AY 651P, BSM-9100 with AY 653P, BSM-9100 with YJ 671P, BSM-9101, BSM-9172, BSM-9173, BSM-9510, BSM-9510 Life Scope M, BSM-9510K, BSM-9800 Life Scope S, BSS 9800K, Life Scope LC BSM 3101K, PVM 2703 |
| Philips | Tempus Pro |
| Smiths Medical / BCI | 9200(Advisor) |
| Spacelabs | 93300 eLance Series |
| Welch Allyn | 1500, Atlas, Propaq CS, Propaq Encore |
| YSI | 400 Series, 4600 |
| Zoll | Propaq MD, Thermogard Xp, X Series |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| YSI | 401 |
| Biolight | 15-100-0028 |
| Bionet | TEM-PRV-RA |
| CASMed | 01-02-0379, 01-02-0327 |
| Criticare / CSI | 420 |
| Datex-Ohmeda | M1024247 |
| Digicare | TP004(10296-2) |
| Draeger / Air Shields | 5201327, 5201319 |
| DRE | P04022 |
| Fukuda Denshi | 401J |
| GE Healthcare | 165622, 401/1 |
| GE Healthcare / Marquette | 9445-004 |
| Invivo | 9390H |
| Ivy Biomedical | 590003 |
| Mindray / Datascope | 0206-02-0001, 0509-10-00095 |
| Nihon Kohden | YSI-401, TT-411T |
| Philips | 989706000861 |
| Smiths Medical | WWV3418 |
| Spacelabs | 690-0294-0, 360175-001, 690-0272-00 |
| Unimed | T2252-AG |
| Welch Allyn | 9293-056-50, 008-0230-00 |
| Zoll | 8000-0668 |
IPR Medical buys, sells, repairs, and stocks parts for adult temperature probes and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by YSI, Philips, Nellcor, or any other manufacturer or supplier named on this page. YSI, Philips, Nellcor, OxiMax, Tempus Pro, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the YSI 401 Compatible Adult General Temperature Probe?
The IPR Medical TS-Y400-AG30 is a compatible aftermarket (not OEM) adult general (oral/rectal) temperature probe that replaces the YSI 401. It pairs a 0.16 in (4.0 mm) probe tip with a 9.8 ft (3.0 m) cable and uses 400 Series temperature technology. Because it is reusable, the same probe can go back into service once it has been cleaned between patients.
Compatible Monitor Models
The list of compatible equipment for this probe spans many manufacturers. On that list are select Nihon Kohden models (the BSM-2301 and BSM-6501, for example), select Edan models including the iM60 and M50, and select Criticare / CSI models like the 507E and 8100. Select Welch Allyn models such as the Propaq CS and Propaq Encore, and select Zoll models, also appear; every remaining entry is in the Compatible Monitor Models table on the Specifications tab, where you should confirm your exact model before ordering.
Design and Construction
For adult general (oral/rectal) use, the TS-Y400-AG30 combines a 0.16 in (4.0 mm) tip, 400 Series temperature technology, and 9.8 ft (3.0 m) of cable. Each probe ships in an individual bag and is intended for repeated use. Clean and disinfect the probe between patients as your facility protocol requires, and look over the tip and cable before each use.
When to Replace Your YSI 401 Compatible Temperature Probe
Take the probe out of service if readings wander, take noticeably longer than usual to stabilize, or stop agreeing with a reference thermometer. A cracked or loose tip, a nicked or split cable jacket, and visible damage at the monitor connector are other clear reasons to replace it. When a known-good probe reads normally on the same monitor, the original probe is almost certainly the cause.
Cross Reference and Interchange Part Numbers
Beyond the YSI 401, this probe cross-references to OEM numbers including Nihon Kohden YSI-401 and TT-411T, Welch Allyn 008-0230-00 and 9293-056-50, Zoll 8000-0668, and GE Healthcare / Marquette 9445-004. Look under Cross Reference / Interchange Part Numbers on the Specifications tab for the remaining numbers, arranged by brand.
Why Source Temperature Probes from IPR Medical?
Reusable oral/rectal probes wear with routine handling and cleaning. IPR Medical repairs patient monitors and infusion pumps in-house, and the same ISO 9001:2015-certified independent service organization buys, sells, and stocks the parts that equipment needs. Browse our temperature probes and cables or call 855-477-8866 with any questions.
IPR Medical buys, sells, repairs, and stocks parts for adult temperature probes and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by YSI, Philips, Nellcor, or any other manufacturer or supplier named on this page. YSI, Philips, Nellcor, OxiMax, Tempus Pro, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.