3-Lead Telemetry ECG Leadwire Set Compatible with Philips 989803151971, AHA, Grabber/Pinch, Shower Shield, 3 ft (0.9 m)
$60.00The 989803151971 compatible 3-lead telemetry ECG leadwire set (SKU EL-TPH3-90G-A) is a reusable, aftermarket replacement (not OEM) with grabber (pinch) ends, AHA color coding, and a DIN-style connector with a shower shield.
Lead Count
3-Lead (Limb Leads)Color Code
AHA (RA White, LA Black, LL Red)Electrode End
Grabber / PinchDevice Connector
DIN-Style with Shower ShieldLead Length
3 ft (0.9 m)Patient Size
Adult / PediatricLifecycle
ReusableReplaces
Philips 989803151971, 989803133841Works with: select telemetry transmitters and monitors; see the Specifications tab for the full list of compatible models. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring and telemetry equipment. Call 855-477-8866 or email cs@iprmed.com.
-
AAMI Compatible IBP Adapter Cable with BD (Argon) Connector — IBP-AM-BD40
$62.50The AAMI-compatible IBP adapter cable with BD (Argon) connector (SKU IBP-AM-BD40) is a reusable aftermarket replacement (not OEM) that connects AAMI-standard patient monitors to BD (Argon) disposable transducers.
Cable Type
IBP Adapter CableMonitor Connection
AAMI StandardTransducer Connection
BD (Argon)Cable Length
Approx. 13 ft (4.0 m)Lifecycle
ReusablePackaging
1 per BagReplaces
Alaris 684085; Datascope 001C-30-70758; Draeger 2606488; Edan M13-36087; Mindray 6200-30-09743, 6000-10-02106; Spacelabs 690-0021-00Works with: AAMI-standard patient monitors, including select Spacelabs, Invivo, Welch Allyn, Mindray/Datascope, Stryker/Medtronic/Physio-Control Lifepak, and Zoll models. See the Specifications tab for the full list.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
AAMI Compatible IBP Adapter Cable with Edwards Connector, 4.0m | IBP-AM-EW40
$50.00The AAMI compatible IBP adapter cable with Edwards connector (SKU IBP-AM-EW40) is a reusable, aftermarket replacement (not OEM) that connects AAMI-standard patient monitors to Edwards-type disposable pressure transducers in critical care, operating room, and ICU environments.
Monitor-End Connector
AAMI StandardTransducer-End Connector
Edwards ConnectorCable Length
13 ft (4.0 m)Lifecycle
ReusablePackaging
1 Cable per BagReplaces
Datascope 0010-21-43094, Draeger 2606489, Edwards 896019021, Mindray 0010-10-42640, Zoll 8000-0665Works with: select AAMI-standard monitors from Invivo, Spacelabs, Mindray / Datascope, Welch Allyn, Smiths Medical / BCI, Zoll, and other manufacturers. See the Specifications tab for the full list.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
AAMI Compatible IBP Adapter Cable with Utah Connector, 13 ft | IBP-AM-UT40
$50.00The AAMI compatible IBP adapter cable with Utah connector (SKU IBP-AM-UT40) is a reusable, aftermarket replacement (not OEM) that connects AAMI-standard patient monitors to Utah-type disposable pressure transducers for invasive blood pressure (IBP) monitoring in the OR, ICU, and critical care settings.
Cable Type
IBP Adapter CableMonitor-End Connector
AAMITransducer-End Connector
UtahCable Length
13 ft (4.0 m)Lifecycle
ReusablePackaging
Bag of 1Replaces
Utah Medical 650-208Works with: select AAMI-standard patient monitors from Spacelabs, Invivo, Mindray / Datascope, Welch Allyn, Zoll, Edan, and other manufacturers, and Utah-type disposable pressure transducers. See the Specifications tab for the full list.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring systems. Call 855-477-8866 or email cs@iprmed.com.
-
AAMI Compatible One-Piece ECG Cable, 3-Lead Snap, AHA | EC-3001S-A
$50.00The AAMI-compatible one-piece 3-lead ECG cable (SKU EC-3001S-A) is a reusable aftermarket replacement (not OEM) that combines the trunk and leadwires into a single integrated assembly for direct connection to AAMI-standard patient monitors and defibrillators.
Cable Construction
One-Piece (Integrated Trunk and Leadwires)Lead Count
3-LeadElectrode End
SnapColor Code
AHAMonitor Connection
AAMI StandardCable Length
Approx. 11 ft (3.4 m)Lifecycle
ReusableReplaces
Edan 01.57.471095-10; Zoll 8000-0025-02; Mindray 009-005268-00Works with: AAMI-standard patient monitors and defibrillators, including select Edan, Zoll, Medtronic/Physio-Control Lifepak, Mindray/Datascope, Nihon Kohden, Spacelabs, and Criticare models. See the Specifications tab for the full list.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring systems. Call 855-477-8866 or email cs@iprmed.com.
-
AAMI Compatible One-Piece ECG Cable, 5-Lead Snap, AHA | EC-5001S-A
$60.00The AAMI compatible one-piece 5-lead ECG cable (SKU EC-5001S-A) is a reusable, aftermarket replacement (not OEM) that connects directly to AAMI-standard patient monitors and defibrillators, combining the trunk and leadwires into a single integrated assembly for fewer connection points and a cleaner bedside setup.
Cable Construction
One-Piece (Integrated Trunk and Leadwires)Lead Count
5-LeadElectrode End
SnapColor Code
AHAMonitor Connection
AAMI StandardApprox. Cable Length
Trunk ~8 ft (2.4 m), leadwires ~3 ft (0.9 m)Lifecycle
ReusableReplaces
Zoll 8000-1005-01Works with: select AAMI-standard monitors and defibrillators from Zoll (M, E, and R Series), Physio-Control (Lifepak 5 through 10), Mindray / Datascope, Nihon Kohden, Spacelabs, Criticare, Invivo, and other manufacturers. See the Specifications tab for the full list.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring systems. Call 855-477-8866 or email cs@iprmed.com.
-
Compatible AAMI IBP Adapter Cable with Medex Abbott Connector | IBP-AM-MXT40
$50.00The Abbott/Medex compatible AAMI IBP adapter cable (SKU IBP-AM-MXT40) is a reusable, aftermarket replacement (not OEM) that connects AAMI-standard patient monitors to Abbott/Medex disposable pressure transducers.
Cable Type
IBP Adapter CableTransducer Compatibility
Abbott/Medex Disposable TransducerMonitor Connection
AAMI StandardCable Length
Approx. 13 ft (4.0 m)Lifecycle
ReusablePackaging
1 per BagReplaces
Draeger 2606490, Hospira / Abbott / ICU Medical 42661-14, Mindray / Datascope 001C-30-70760, Smiths Medical / BCI MX95114, Zoll 8300-0788-01Works with: select patient monitors from Mindray, Spacelabs, Invivo, GE Healthcare, Physio-Control, Welch Allyn, BCI/Smiths Medical, Edan, Zoll, and others. See the Specifications tab for the full list.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Compatible GE Dinamap 107368 Neonatal 2-Tube NIBP Air Hose, 12 ft (3.6 m), Gray Shroud to Female Slip Luer
$60.00The GE Dinamap 107368 compatible neonatal NIBP air hose is a reusable, aftermarket replacement (not OEM) dual-tube hose for neonatal non-invasive blood pressure monitoring, built to OEM fit, form, and function.
Hose Type
Dual Tube (2-Tube)Patient Size
NeonateHose Length
12 ft (3.6 m)Use With
2-Tube Neonatal CuffsLifecycle
ReusablePackaging
1 per BagReplaces
GE Healthcare 107368Works with: select GE Dinamap Pro Series, ProCare, Compact, and MPS monitors and the GE Carescape B650, V100, and VC150. See the Specifications tab for the full list.
IPR Medical buys, sells, repairs, and stocks parts for Dinamap and Carescape patient monitors. Call 855-477-8866 or email cs@iprmed.com.
-
Critikon/GE Compatible NIBP Air Hose, Adult/Pediatric Dual-Tube, 8 ft | 107365
$50.00The GE Healthcare / Critikon 107365 compatible NIBP air hose is a reusable, aftermarket replacement (not OEM) adult/pediatric dual-tube hose for GE Healthcare, Critikon, and Dinamap non-invasive blood pressure monitors, built to maintain a secure, leak-free air path between the monitor and the cuff.
Tube Configuration
Dual-TubePatient Size
Adult/PediatricHose Length
8 ft (2.5 m)Cuff Connector
Threaded / ScrewConnects To
GE / Critikon / Dinamap NIBP monitorsLifecycle
ReusableReplaces
GE Healthcare / Critikon / Dinamap 107365Works with: select GE Healthcare / Critikon Dinamap Pro, ProCare, and Compact models, the MPS, and the Carescape B650, V100, and VC150. See the Specifications tab for the full list.
IPR Medical buys, sells, repairs, and stocks parts for GE Healthcare, Critikon, and Dinamap patient monitoring systems. Call 855-477-8866 or email cs@iprmed.com.
-
Critikon/GE Compatible NIBP Cuff, Adult 23–33 cm, Two-Tube Screw | 2464
$17.50The GE Healthcare / Critikon 2464 compatible adult NIBP cuff is a reusable, aftermarket replacement (not OEM) two-tube blood pressure cuff with an integrated bladder and screw connectors that mate with GE, Critikon, and Dinamap screw-type NIBP hose connections.
Patient Size
AdultLimb Circumference
23–33 cmTube Configuration
Two-Tube (Double Tube)Bladder
IntegratedConnector Type
Two-Tube ScrewLifecycle
ReusableReplaces
GE Healthcare / Critikon 2464Works with: GE Healthcare, Critikon, and Dinamap NIBP systems that use two-tube screw-type hose connections.
IPR Medical buys, sells, repairs, and stocks parts for GE Healthcare, Critikon, and Dinamap patient monitoring systems. Call 855-477-8866 or email cs@iprmed.com.
-
Datascope / Mindray Compatible Adult General (Oral/Rectal) Temperature Probe, 10 ft (3.0 m) – 040-000055-00
$75.00The Datascope / Mindray 040-000055-00 compatible adult general-purpose (oral/rectal) temperature probe (SKU TS-MRB-AG30) is a reusable, aftermarket replacement (not OEM) that plugs directly into the monitor’s temperature port without an adapter, built to OEM fit, form, and function.
Probe Type
General Purpose (Oral/Rectal)Patient Size
AdultProbe Tip Diameter
0.16 in (4.0 mm)Cable Length
10 ft (3.0 m)Sensor Type
NTC Thermistor, R25 = 2.252 kΩLifecycle
ReusablePackaging
1 Probe per BagReplaces
Datascope / Mindray 040-000055-00Works with: Datascope / Mindray Passport V, V-Series, V12, and V21 patient monitors. Browse our full line of compatible temperature probes and adapters.
IPR Medical buys, sells, repairs, and stocks parts for Datascope / Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Datascope / Mindray Compatible Adult Skin Surface Temperature Probe, 10 ft (3.0 m) – 040-000057-00
$75.00The Datascope / Mindray 040-000057-00 compatible adult skin surface temperature probe (SKU TS-MRB-AS30) is a reusable, aftermarket replacement (not OEM) that connects directly to the monitor’s temperature port without an adapter, built to OEM fit, form, and function.
Probe Type
Skin SurfacePatient Size
AdultSensor Disc Diameter
0.35 in (9.0 mm)Sensor Type
NTC Thermistor, R25 = 2.252 kΩCable Length
10 ft (3.0 m)Lifecycle
ReusableReplaces
Datascope / Mindray 040-000057-00Works with: Datascope / Mindray Passport V, V-Series, V12, and V21 patient monitors. Browse our full line of compatible temperature probes and adapters.
IPR Medical buys, sells, repairs, and stocks parts for Datascope / Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.