AAMI Compatible IBP Adapter Cable with Utah Connector, 13 ft | IBP-AM-UT40
The AAMI compatible IBP adapter cable with Utah connector (SKU IBP-AM-UT40) is a reusable, aftermarket replacement (not OEM) that connects AAMI-standard patient monitors to Utah-type disposable pressure transducers for invasive blood pressure (IBP) monitoring in the OR, ICU, and critical care settings.
| Cable Type | IBP Adapter Cable |
| Monitor-End Connector | AAMI |
| Transducer-End Connector | Utah |
| Cable Length | 13 ft (4.0 m) |
| Lifecycle | Reusable |
| Packaging | Bag of 1 |
| Replaces | Utah Medical 650-208 |
Works with: select AAMI-standard patient monitors from Spacelabs, Invivo, Mindray / Datascope, Welch Allyn, Zoll, Edan, and other manufacturers, and Utah-type disposable pressure transducers. See the Specifications tab for the full list.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring systems. Call 855-477-8866 or email cs@iprmed.com.
Product Specifications
| Part Number | IBP-AM-UT40 |
| Product Type | Compatible IBP Adapter Cable (Aftermarket) |
| Monitor-End Connector | AAMI 6-Pin, Round Male, Keyed |
| Transducer-End Connector | Utah |
| Cable Length | 13 ft (4.0 m) |
| Cable Diameter | 4 mm |
| Cable Color | Gray |
| Jacket Material | TPU |
| Reusability | Reusable |
| Latex-Free | Yes |
| Sterile | No |
| Packaging | Bag of 1 |
| Certifications | FDA, CE, ISO 10993, RoHS Compliant |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| AAMI | All AAMI-Standard Monitors |
| Bard Medical | H8000 |
| Dixtal | DX 2020, DX 2021, DX 2023 |
| Edan | iM8, iM80 |
| Generra | 710C |
| Invivo | 3500, 3550, 4500 Plus, Escort 100, Escort 200, Escort 300, M12, Millennia, Omnitrak 4000 |
| Ivy Biomedical | 400, 700 |
| Mindray > Datascope | DPM4, DPM5, PM 9000 Express, Passport |
| Mortara > Burdick | 3100 |
| PaceTech | Vitalmax 4000 |
| Philips | 5 microvolt, 78205, 8805 |
| Smiths Medical > BCI | 9100 Series, 9200 Advisor Series |
| Spacelabs | 300, 400, 500, 600, 700 Surgical Series, 90308, 90311, 90331, 90402, 90403, 90470, 90496, 90603A, 91496, Alpha 7, Alpha PC, MOD-CD, PC Express, Scout TPC 90496, Tel/Vitatek, Ultraview Series |
| Stryker > Medtronic > Physio Control | Lifepak 12, Lifepak 15 |
| Tektronix | 400 Series |
| Vitalert | 2000 |
| Welch Allyn | 106EL, Encore, PIC, Propaq 102, Propaq 104, Propaq 106 Acuity, Propaq 205 |
| Zoll | M Series, Propaq MD, Thermogard XP, X Series |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| IPR Medical | IBP-AM-UT40 |
| Utah Medical | 650-208 |
| Cables and Sensors | IC-6P-UT0 |
IPR Medical buys, sells, repairs, and stocks parts for AAMI-compatible patient monitoring systems. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Utah Medical, Philips, or any other manufacturer or supplier named on this page. Utah Medical, Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the AAMI Compatible IBP Adapter Cable (IBP-AM-UT40)?
The IBP-AM-UT40 is a compatible aftermarket invasive blood pressure (IBP) adapter cable that bridges an AAMI 6-pin patient monitor input and a Utah-type disposable pressure transducer. It carries the low-level pressure signal from the transducer to the monitor, allowing clinicians to view real-time arterial, central venous, and other invasive pressure waveforms. This cable is a compatible replacement and is not an OEM product; IPR Medical is not affiliated with, sponsored by, or endorsed by any original equipment manufacturer referenced on this page.
Compatible Monitor Models
Because it terminates in the universal AAMI 6-pin keyed connector, the IBP-AM-UT40 works across a broad range of patient monitors that follow the AAMI pressure interface standard. Confirmed compatible systems include monitors from Bard Medical, Dixtal, Edan, Generra, Invivo, Ivy Biomedical, Mindray/Datascope, Mortara/Burdick, PaceTech, Philips, Smiths Medical/BCI, Spacelabs, Stryker/Medtronic/Physio Control, Tektronix, Vitalert, Welch Allyn, and Zoll. The transducer end mates with Utah-style disposable pressure transducers. A full model-by-model breakdown is provided in the Specifications tab. If your monitor or transducer is not listed, contact IPR Medical and we will help verify the correct cable for your configuration.
Design and Construction
This adapter cable measures 13 ft (4.0 m) and uses a flexible 4 mm gray TPU jacket selected for durability and resistance to repeated handling, coiling, and wipe-down disinfection. The monitor end features a round, keyed male 6-pin AAMI connector for a secure, correctly oriented fit, while the transducer end provides a Utah connector. The cable is latex-free and reusable, and is manufactured to FDA, CE, ISO 10993, and RoHS standards. As a reusable component, it is designed to deliver a clean, stable pressure signal across many transducer change-outs.
When to Replace Your IBP Adapter Cable
An IBP adapter cable should be replaced when it shows signs of physical or electrical wear that can compromise pressure readings. Common indicators include a noisy, drifting, or dampened waveform, intermittent signal loss when the cable is flexed, visible cracking or kinking of the jacket, bent or corroded connector pins, or a connector that no longer seats firmly in the monitor or transducer. Because invasive pressure monitoring directly informs clinical decisions, keeping a tested spare cable on hand helps avoid downtime during critical care. IPR Medical stocks these cables for fast replacement and can also evaluate and repair patient monitoring assets that need service.
Cross Reference and Interchange Part Numbers
The IBP-AM-UT40 is referenced across the industry under several interchange numbers. It corresponds to the Utah Medical 650-208 Utah-connector interface and to the Cables and Sensors equivalent IC-6P-UT0. These cross-references are provided to help biomedical and procurement teams confirm compatibility when sourcing replacement cables across different supplier catalogs. A complete interchange table is provided in the Specifications tab.
Why Source IBP Adapter Cables from IPR Medical?
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion systems. Beyond supplying compatible aftermarket cables and sensors, our team supports biomedical departments with equipment repairs, software updates, and hard-to-find replacement components, helping facilities keep monitoring systems in service and control costs. For pricing, availability, or compatibility verification on the IBP-AM-UT40, our staff is ready to help.
IPR Medical buys, sells, repairs, and stocks parts for AAMI-compatible patient monitoring systems. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Utah Medical, Philips, or any other manufacturer or supplier named on this page. Utah Medical, Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.