Compatible AAMI IBP Adapter Cable with Medex Abbott Connector | IBP-AM-MXT40
The IBP-AM-MXT40 is a compatible aftermarket replacement IBP adapter cable designed for use with Abbott/Medex disposable transducers and AAMI 6-pin patient monitors. This reusable cable measures 4.0 meters (approximately 13 ft) in length and features a keyed 6-pin AAMI monitor-end connector paired with an RJ12 Medex/Abbott transducer-end connector. The cable is constructed with a durable TPU jacket, is latex-free, and carries CE certification for reliable clinical performance in ICU, OR, and critical care environments.
This cable is compatible with a broad range of patient monitors from Mindray, Spacelabs, Invivo, Philips, Physio-Control, Welch Allyn, BCI/Smiths, Edan, and many others — making it a versatile solution for biomedical departments managing diverse monitoring fleets. IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
| Part Number | IBP-AM-MXT40 |
| Category | IBP Adapter Cable |
| Condition | Aftermarket Compatible |
| Cable Length | 4.0 m (approx. 13 ft) |
| Monitor End Connector | Round, Male 6-Pin, Keyed (AAMI) |
| Transducer End Connector | RJ12 6P6C Medex/Abbott |
| Transducer Brand Compatibility | Abbott/Medex Disposable Transducer |
| Cable Material | TPU Jacket |
| Latex-Free | Yes |
| Sterile | No |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
| Certifications | CE, FDA |
Compatible Monitor Models
| Manufacturer / Supplier | Compatible Models |
| AAMI | All |
| Bard Medical | H8000 |
| BCI / Smiths Medical | 3100, 9100 Series, 9200 Advisor Series, 9200 (Advisor) |
| Burdick / Mortara | 400 |
| Contec | Patient Simulator MS400 |
| Criticare / CSI | 500, 2000 |
| Dixtal / Philips | DX 2020, DX 2021, DX 2023 |
| Edan | iM8, iM80 |
| GE Healthcare | Corometrics TRAM 450SL, Marquette i/9500 (Tram 451N5/851N5), Marquette Tram 400, Marquette Tram 450, TRAM 451M |
| Generra | 710C |
| Invivo | 300, 3550, 4500 Plus, Escort 100, Escort 200, Escort 300, M12, Millennia |
| Ivy Biomedical | 400, 700 |
| Mindray | DPM 4, DPM 5, MEC 1000, MEC 1200, MEC 2000, Passport, PM 5000, PM 6000, PM 7000, PM 7000 Standard, PM 8000, PM 8000 Express, PM 9000, PM 9000 Express |
| Nellcor / Invivo | 3500, Omnitrak 4000 |
| Pace Tech | Vitalmax 4000 |
| Philips | 5 Microvolt, 78205, 8805 |
| Physio-Control / Stryker | Lifepak 12, Lifepak 15 |
| Soma Technology | 700 |
| Spacelabs | 600, 700 Surgical Series, 90308, 90311, 90331, 90402, 90403, 90470, 90496, 90603A, 91496, Alpha 7, Alpha PC, MOD-CD, PC Express, Scout TPC 90496, Tel/Vitatek |
| Tektronix | 400 Series |
| Venni | All |
| Welch Allyn / Stryker | 106EL, Encore, PIC, Propaq 102, Propaq 104, Propaq 106 Acuity, Propaq 205 |
| Zoll | Propaq MD, X Series |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| 360Biomedical | 360Bio-4643 |
| AMC / LifeSync | CB-21101 |
| Argo Biomedical | ARIBP-AM-MXT40 |
| Avante Healthcare | NBAA6106-5 |
| Cables and Sensors | IC-6P-MX0 |
| Draeger | 2606490 |
| Gopher Medical | GMIBP-AM-MXT40 |
| Hospira / Abbott / ICU Medical | 42661-14 |
| Hue Chi | IBP-AM-MXT40 |
| M&R Medical | IC-6P-MX0 |
| MARS | MARS-IBP-000010 |
| Mindray / Datascope | 001C-30-70760 |
| Revanix | RVBIBPAMMXT401 |
| Smiths Medical / BCI | MX95114 |
| Unimed | BC-6P-MX |
| Viamed | 6015000 |
| Zoll | 8300-0788-01 |
IPR Medical buys, sells, repairs, and stocks parts for IBP adapter cables and patient monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
What Is the IBP-AM-MXT40 Adapter Cable?
The IBP-AM-MXT40 is a compatible aftermarket replacement invasive blood pressure (IBP) adapter cable that bridges AAMI 6-pin patient monitors with Abbott/Medex disposable pressure transducers. At 4.0 meters (approximately 13 ft) in length, it provides ample reach from the bedside monitor to the transducer mounting point, which is especially important in ICU, OR, and emergency care environments where equipment may be positioned at a distance from the patient. This is not an OEM product — it is an aftermarket compatible replacement engineered to meet the performance requirements of clinical IBP monitoring.
Compatible Monitor Models
This cable is designed for use with any AAMI-standard 6-pin monitor and has been confirmed compatible with a wide range of patient monitoring platforms. Compatible monitors include models from Mindray (DPM 4, DPM 5, PM 5000 through PM 9000 Express, MEC series, Passport), Spacelabs (90308, 90311, 90331, 90402, 90403, 90470, 90496, 90603A, 91496, Alpha 7, Alpha PC, MOD-CD, PC Express, Scout TPC), Invivo (300, 3550, 4500 Plus, Escort series, M12, Millennia), Welch Allyn / Stryker (Propaq 102, 104, 106 Acuity, 205, 106EL, Encore, PIC), Physio-Control (Lifepak 12, Lifepak 15), Philips (5 Microvolt, 78205, 8805), BCI/Smiths Medical (3100, 9100 Series, 9200 Advisor), Edan (iM8, iM80), Dixtal (DX 2020, DX 2021, DX 2023), Zoll (Propaq MD, X Series), Criticare (500, 2000), Bard Medical (H8000), Burdick/Mortara (400), Pace Tech (Vitalmax 4000), Tektronix (400 Series), Generra (710C), Soma Technology (700), and Venni (all models).
Design and Construction
The IBP-AM-MXT40 features a thermoplastic polyurethane (TPU) jacket, which provides superior flexibility and resistance to abrasion, kinking, and repeated handling compared to standard PVC constructions. The monitor end uses a round, keyed male 6-pin AAMI connector, while the transducer end uses an RJ12 6P6C connector designed specifically for Abbott/Medex disposable pressure transducers. The cable is latex-free and reusable, making it appropriate for repeated use in clinical departments. CE and FDA certifications confirm that the cable meets applicable regulatory standards for use in hospital and clinical settings.
When to Replace Your IBP Adapter Cable
IBP adapter cables should be inspected regularly and replaced when connector pins show signs of corrosion or physical damage, when the cable jacket is cracked, frayed, or kinked near the connector ends, when the cable fails a known-good bench test with a reference transducer, or when the monitor reports intermittent or erratic IBP waveforms despite a properly primed and zeroed transducer. In high-acuity departments where IBP monitoring is continuous, keeping spare adapter cables on hand prevents delays during critical procedures. Proactive replacement as part of a scheduled PM cycle reduces the risk of unexpected signal loss during patient monitoring.
Cross Reference and Interchange Part Numbers
The IBP-AM-MXT40 is a widely referenced compatible cable that replaces part numbers from multiple manufacturers and distributors. Known interchangeable part numbers include Hospira / Abbott / ICU Medical 42661-14, AMC/LifeSync CB-21101, Cables and Sensors IC-6P-MX0, Draeger 2606490, Argo Biomedical ARIBP-AM-MXT40, Mindray/Datascope 001C-30-70760, Smiths Medical/BCI MX95114, Hue Chi IBP-AM-MXT40, and Zoll 8300-0788-01. If you are sourcing a replacement for any of these part numbers, this cable is the appropriate compatible substitute.
Why Source IBP Adapter Cables from IPR Medical?
IPR Medical specializes in the sale, repair, and ongoing support of patient monitoring accessories and capital equipment. Our team works directly with biomedical engineers, clinical engineering departments, and materials managers to ensure that the correct compatible replacement parts are identified quickly and delivered reliably. Whether you need a single IBP adapter cable for an immediate repair or a stocked quantity for a department-wide standardization project, IPR Medical can support your procurement needs. We carry a broad inventory of IBP adapter cables across all major connector types and monitor platforms, and our technical staff can assist with cross-referencing part numbers when the OEM reference is unclear.
IPR Medical buys, sells, repairs, and stocks parts for IBP adapter cables and patient monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.















