Datascope / Mindray Compatible Pediatric/Neonate Skin Surface Temperature Probe, 10 ft (3.0 m) – 040-000058-00
The Datascope / Mindray 040-000058-00 compatible pediatric/neonate skin surface temperature probe (SKU TS-MRB-PS30) is a reusable aftermarket replacement (not OEM) built to OEM fit, form, and function, with a small flat sensing disc sized for pediatric and neonatal skin.
| Probe Type | Skin Surface |
| Patient Size | Pediatric / Neonate |
| Sensor Disc Diameter | 0.24 in (6.0 mm) |
| Sensor Type | NTC Thermistor, R25 = 2.252 kΩ |
| Cable Length | 10 ft (3.0 m) |
| Lifecycle | Reusable |
| Replaces | Datascope / Mindray 040-000058-00 |
Works with: Datascope / Mindray Passport V, V-Series, V12, and V21 patient monitors. Browse our full line of compatible temperature probes and adapters.
IPR Medical buys, sells, repairs, and stocks parts for Datascope / Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Non-OEM) |
| IPR Medical SKU | TS-MRB-PS30 |
| Replaces OEM Part Number | Datascope / Mindray 040-000058-00 |
| Probe Type | Skin Surface |
| Patient Size | Pediatric / Neonate |
| Usage | Reusable |
| Sensor Disc Diameter | 0.24 in (6.0 mm) |
| Cable Length | 10 ft (3.0 m) |
| Monitor Connector | 5-Pin, D-Shaped, Keyed |
| Sensor Type | NTC Thermistor, R25 = 2.252 kΩ |
| Measurement Range | 77 °F to 113 °F (25 °C to 45 °C) |
| Channel | Single |
| Sterile | No |
| Packaging | 1 Probe per Bag |
| Manufacturing Standard | Produced in FDA-registered, ISO 13485:2016-certified facilities |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Datascope / Mindray | Passport V, V-Series, V12, V21 |
| Contec | MS400 Patient Simulator |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Datascope / Mindray (OEM) | 040-000058-00 |
| Unimed | TDT-PS |
| IPR Medical (Compatible) | TS-MRB-PS30 |
IPR Medical buys, sells, repairs, and stocks parts for the Datascope / Mindray Passport V and V-Series monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datascope, Mindray, or any other manufacturer or supplier named on this page. Datascope, Mindray, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Datascope 040-000058-00 Compatible Temperature Probe?
The TS-MRB-PS30 is a compatible aftermarket replacement for the Datascope / Mindray 040-000058-00 pediatric/neonate skin surface temperature probe. It is not an OEM part. The probe is reusable and single-channel, and it provides continuous, non-invasive skin temperature monitoring for pediatric and neonatal patients. Typical settings include the NICU, pediatric ICU, and pediatric surgical and recovery areas. It connects directly to the monitor’s temperature input, so no adapter cable is needed. Its electrical characteristics match the OEM probe, so readings stay consistent with what clinicians expect from the original part.
Compatible Monitor Models
This probe is compatible with the Datascope / Mindray Passport V, V-Series, V12, and V21 patient monitors, which use a 5-pin, D-shaped keyed temperature connector. It also works with the Contec MS400 patient simulator, so biomedical technicians can use it for bench testing and preventive maintenance checks. It is not intended for the newer Mindray BeneView, iPM, iMEC, or ePM platforms, which use a different connector. It is also not intended for older Datascope monitors that take 400-series mono-plug probes.
Design and Construction
The probe ends in a flat 0.24 in (6.0 mm) sensing disc. This disc is smaller than the 9.0 mm disc on the adult skin probe, so it fits small patients and neonates. It is typically held in place with an adhesive skin probe cover. The 10 ft (3.0 m) cable reaches a bedside or transport-mounted monitor without straining the connector. The sensing element is an NTC thermistor with a nominal resistance of 2.252 kΩ at 77 °F (25 °C), and it reads accurately from 77 °F to 113 °F (25 °C to 45 °C). The keyed 5-pin connector seats in only one orientation, which prevents misconnection. Each probe ships non-sterile in an individual bag. It is designed to be cleaned and disinfected between patients according to facility protocol.
When to Replace Your Temperature Probe
Reusable skin temperature probes wear out from repeated cleaning, adhesive removal, flexing, and plugging and unplugging. Replace the probe if the cable jacket is cracked, discolored, or stiff. The same applies to a damaged or lifting sensing disc, a torn strain relief, or bent or corroded connector pins. Also replace it if readings drift, fluctuate, or disagree with a reference thermometer. Intermittent “probe off” or “temp error” alarms that clear when the cable is moved are another warning sign. Remove any probe that fails a patient-simulator check during preventive maintenance from service immediately. In neonatal settings, even small temperature errors matter, so keeping a spare on hand is recommended.
Cross Reference and Interchange Part Numbers
The TS-MRB-PS30 cross-references to Datascope / Mindray OEM part number 040-000058-00 and to Unimed part number TDT-PS. Materials managers can use any of these numbers to confirm fit when replacing existing stock or consolidating purchasing across facilities. This is the pediatric/neonate skin surface version within the Passport V temperature family. The adult general-purpose probe (040-000055-00), pediatric general-purpose probe (040-000056-00), and adult skin probe (040-000057-00) use the same connector with different sensor ends.
Why Source Temperature Probes from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that specializes in patient monitoring and infusion equipment. We buy, sell, repair, and stock parts for Datascope / Mindray monitors, and our compatible accessories are held in inventory for fast shipping. Our in-house technical team helps biomedical departments confirm compatibility before purchase, match cross-reference numbers, and source hard-to-find parts. We also provide monitor repair, refurbishment, and equipment sales to support your fleet beyond accessories.
IPR Medical buys, sells, repairs, and stocks parts for the Datascope / Mindray Passport V and V-Series monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datascope, Mindray, or any other manufacturer or supplier named on this page. Datascope, Mindray, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.