IPR Medical

GE Healthcare TS-E-D Compatible Adult Ear Clip SpO2 Sensor, TruSignal, Reusable, 3.3 ft (1.0 m)

$100.00

The GE TruSignal ear sensor TS-E-D compatible replacement is a reusable, aftermarket adult ear clip SpO2 sensor (not OEM) for GE and Datex-Ohmeda monitors configured with TruSignal SpO2, built to OEM fit, form, and function.

Sensor Type Ear Clip
Patient Size Adult / Pediatric
SpO2 Technology GE TruSignal
Cable Length 3.3 ft (1.0 m), short sensor
Lifecycle Reusable

Works with: TruSignal-equipped GE CARESCAPE B650/V100/ONE/Canvas, Dinamap B125, B20/B40, Aisys, and Datex-Ohmeda S/5, AS/3, CS/3, Cardiocap/5, and 3800/3900 oximeters. GE CARESCAPE and Dinamap monitors require a TruSignal interconnect cable. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.

IPR Medical buys, sells, repairs, and stocks parts for GE and Datex-Ohmeda patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: SS-018-AE10 Categories: , Tags: ,
Send In GE Healthcare TS-E-D Compatible Adult Ear Clip SpO2 Sensor, TruSignal, Reusable, 3.3 ft (1.0 m) for Repair
Product Type Compatible Replacement (Aftermarket, Not OEM)
IPR Medical SKU SS-018-AE10
OEM Reference GE Healthcare TS-E-D
Sensor Type Ear Clip
Patient Size Adult / Pediatric
SpO2 Technology GE TruSignal
Cable Length 3.3 ft (1.0 m)
Lifecycle Reusable
Packaging 1 per Bag

Compatible Monitor Models

Monitor must be configured with GE TruSignal SpO2. GE CARESCAPE and Dinamap monitors require a TruSignal interconnect cable.

Manufacturer / Series Compatible Models
GE Healthcare CARESCAPE B650, V100, CARESCAPE ONE, CARESCAPE Canvas
GE Healthcare Dinamap B125; B20, B20i, B40
GE Healthcare Anesthesia Aisys, Aisys CS2
GE Healthcare / Corometrics 259
Datex-Ohmeda Monitors S/5 with E-series Modules, S/5 with M-OSAT Module; AS/3 with M-OSAT Module; CS/3 with M-OSAT Module; E-PRESTN Module; Cardiocap/5
Datex-Ohmeda Oximeters 3775, 37xx Series, 3800, 3900, 3900P, 4700, 5250; TuffSat

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
GE Healthcare / Datex-Ohmeda TS-E-D
Praymed PSG0190-S
Sage Services Group P02T-11M
Unimed U903-117

IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE, Dinamap, and Datex-Ohmeda patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. GE Healthcare, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the GE TS-E-D Compatible Ear Clip SpO2 Sensor?

The GE Healthcare TS-E-D compatible SpO2 sensor is a reusable, aftermarket adult ear clip pulse oximetry sensor for GE and Datex-Ohmeda monitors configured with TruSignal SpO2. It is a short-cable sensor with a 3.3 ft (1.0 m) lead and a Datex-style connector, which plugs into a TruSignal interconnect cable or directly into compatible Datex-Ohmeda SpO2 inputs. It is a compatible replacement, not an original GE part, and it is built to OEM fit, form, and function.


Compatible Monitor Models

This compatible sensor is confirmed for use with TruSignal-equipped GE CARESCAPE B650, V100, CARESCAPE ONE, and CARESCAPE Canvas monitors, the Dinamap B125, GE B20, B20i, and B40 monitors, Aisys and Aisys CS2 anesthesia systems, and the Corometrics 259 fetal monitor. It also fits a wide range of Datex-Ohmeda equipment, including S/5 monitors with E-series or M-OSAT modules, AS/3 and CS/3 monitors with the M-OSAT module, the E-PRESTN module, Cardiocap/5, 3775, 37xx-series, 3800, 3900, and 3900P pulse oximeters, the 4700 and 5250 monitors, and the TuffSat handheld oximeter. GE monitors have been offered with TruSignal, Masimo, or Nellcor SpO2, and each requires matching sensors, so confirm your monitor’s SpO2 configuration before ordering.


Design and Construction

The adult ear clip attaches to the earlobe, giving clinicians a monitoring site when fingers are unavailable or poorly perfused, such as during surgery, with peripheral vasoconstriction, or when the hands must remain free for procedures. The short 3.3 ft (1.0 m) cable keeps the sensor lightweight at the patient, and it connects through a TruSignal interconnect cable to reach the monitor. Because the sensor and interconnect cable are separate, a worn sensor can be replaced without replacing the cable. The sensor is reusable after cleaning and disinfection according to facility protocol and ships one per bag.


When to Replace Your GE TruSignal Ear Clip Sensor

Replace the sensor when the monitor reports “SpO2 sensor off,” “no probe,” or sensor fault messages that persist with a known-good interconnect cable, when readings are erratic or the pleth waveform is weak with good sensor placement, or when the clip spring has weakened, the pads are worn or cracked, or the cable jacket is damaged near the clip or connector. Swapping in a known-good sensor and interconnect cable quickly identifies which component is at fault.


Cross Reference and Interchange Part Numbers

This compatible TruSignal adult ear clip SpO2 sensor, IPR Medical SKU SS-018-AE10, cross-references to GE Healthcare / Datex-Ohmeda part number TS-E-D, and interchanges with Praymed PSG0190-S, Sage Services Group P02T-11M, and Unimed U903-117. For GE CARESCAPE and Dinamap monitors, pair it with a TruSignal interconnect cable such as the compatible GE TS-G3, IPR Medical SKU SA-016-24TS. For a direct-connect TruSignal ear clip with an integrated 9.8 ft cable, see the compatible GE TS-E4-GE, SKU SS-016-AE30.


Why Source SpO2 Sensors from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. We carry compatible TruSignal sensors and interconnect cables alongside Masimo and Nellcor options for GE and Datex-Ohmeda monitors, so biomedical and anesthesia technology teams can supply mixed fleets from one source at lower cost than OEM. Our team can help identify each monitor’s SpO2 technology and support your GE equipment with in-house repair services.

IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE, Dinamap, and Datex-Ohmeda patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. GE Healthcare, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.