IPR Medical

Masimo Red LNC-10 (2056) Compatible SpO2 Patient Cable for LNCS Sensors, Reusable, 9.8 ft (3.0 m)

$80.00

The Masimo Red LNC-10 SpO2 cable 2056 compatible replacement is a reusable, aftermarket 9.8 ft cable (not OEM) that connects Masimo LNCS sensors to rainbow SET devices with the red 20-pin connector, built to OEM fit, form, and function.

Monitor Connector Masimo Red (Rainbow SET), 20-Pin
Sensor Compatibility Masimo LNCS
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable

Works with: Masimo Radical-7, Rad-97, Rad-87, Rad-8, Rad-57 family, and Pronto/Pronto-7, Physio-Control Lifepak 15, Zoll X Series, and Comen K12 Pro. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.

IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: SA-009RB-30LS Categories: , Tags: ,
Send In Masimo Red LNC-10 (2056) Compatible SpO2 Patient Cable for LNCS Sensors, Reusable, 9.8 ft (3.0 m) for Repair
Product Type Compatible Replacement (Aftermarket, Not OEM)
IPR Medical SKU SA-009RB-30LS
OEM Reference Masimo 2056 (Red LNC-10)
Cable Type SpO2 Patient / Adapter Cable
Monitor Connector Masimo Red (Rainbow SET), 20-Pin
Sensor Compatibility Masimo LNCS
Cable Length 9.8 ft (3.0 m)
Lifecycle Reusable
Packaging 1 per Bag

Compatible Monitor Models

Device must have a red Masimo rainbow SET patient cable connector.

Manufacturer Compatible Models
Masimo Monitors Radical-7, Radical (20-pin); Rad-97, Rad-97 NIBP, Rad-97 with NomoLine Capnography; Rad-87; Rad-8; Rad-5, Rad-5v
Masimo Handheld Rad-57, Rad-57c, Rad-57cm, Rad-57m; Pronto, Pronto-7, Pronto with Next Generation SpHb
Physio-Control Lifepak 15
Zoll X Series
Comen K12 Pro

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Masimo 2056 (Red LNC-10)
Masimo 2057 (Red LNC-14) (OEM is 14 ft)
GE Healthcare 2059006-001, 2059007-001 (14 ft)
Physio-Control 11996-000324, 11996-000325 (14 ft)
Zoll 8000-0331
Draeger MP02992, MP03196
Spacelabs 010-2193-00
Unimed U708M-87

IPR Medical buys, sells, repairs, and stocks parts for Masimo rainbow SET oximeters, monitors, and defibrillators. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Masimo Red LNC-10 Compatible SpO2 Patient Cable?

The Masimo Red LNC-10 (2056) compatible SpO2 patient cable is a reusable, aftermarket cable that connects standard Masimo LNCS pulse oximetry sensors to Masimo rainbow SET devices with the red 20-pin patient cable connector. At 9.8 ft (3.0 m), it matches the 10 ft length of the OEM Red LNC-10 and lets rainbow-platform monitors, oximeters, and defibrillators use LNCS sensors for routine SpO2 and pulse rate monitoring. It is a compatible replacement, not an original Masimo part, and it is built to OEM fit, form, and function.


Compatible Monitor Models

This compatible cable is confirmed for use with Masimo Radical-7 and Radical (20-pin) monitors, Rad-5, Rad-5v, Rad-8, Rad-87, and Rad-97 devices including Rad-97 NIBP and Rad-97 with NomoLine capnography, Rad-57, Rad-57c, Rad-57cm, and Rad-57m oximeters, and Pronto and Pronto-7 devices, including Pronto with Next Generation SpHb. It also fits the Physio-Control Lifepak 15, the Zoll X Series, and the Comen K12 Pro. The device must have a red Masimo rainbow SET patient cable connector; devices with the gray Masimo SET connector require a standard LNCS cable instead.


Design and Construction

The 9.8 ft (3.0 m) cable gives extra reach for bedside, ICU, OR, and emergency department setups where the monitor sits on a boom, wall mount, or cart away from the patient. The monitor end uses the red 20-pin rainbow connector, and the sensor end accepts Masimo LNCS sensors in adult, pediatric, infant, and neonatal sizes, in both reusable and single-patient-use styles. Rainbow parameters such as SpHb and SpCO require rainbow sensors and cables; with LNCS sensors, this cable supports standard SpO2 and pulse rate monitoring. The cable is reusable after cleaning according to facility protocol and ships one per bag.


When to Replace Your Masimo Red LNC-10 Cable

Replace the cable when the device shows “SpO2 sensor off,” “no cable,” “replace cable,” or cable/sensor fault messages with a known-good LNCS sensor, when saturation or pleth readings drop out as the cable is moved, or when you find a cracked jacket, a loose sensor latch, or bent or corroded pins at the red connector. Longer cables are more likely to be pinched in bed rails or stepped on, so inspect the jacket and strain reliefs during routine checks.


Cross Reference and Interchange Part Numbers

This compatible Masimo Red LNC-10 patient cable, IPR Medical SKU SA-009RB-30LS, cross-references to Masimo 2056 (Red LNC-10), GE Healthcare 2059006-001 and 2059007-001 (14 ft), Physio-Control 11996-000324 and 11996-000325 (14 ft), Zoll 8000-0331, Draeger MP02992 and MP03196, and Spacelabs 010-2193-00. It also interchanges with Unimed U708M-87. The related Masimo 2057 (Red LNC-14) is a 14 ft cable, so confirm the 9.8 ft (3.0 m) length suits your setup if replacing that part. For a shorter cable, IPR Medical also stocks the compatible Masimo Red LNC-4 (2055), SKU SA-009RB-12LS.


Why Source SpO2 Cables from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. We carry compatible Masimo red and gray connector cables, Nellcor, and TruSignal SpO2 accessories in multiple lengths for monitors, oximeters, and defibrillators, so biomedical teams can standardize sourcing at lower cost than OEM. Our team can help identify each device’s SpO2 technology and connector and support your equipment with in-house repair services.

IPR Medical buys, sells, repairs, and stocks parts for Masimo rainbow SET oximeters, monitors, and defibrillators. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.