Masimo 2502 (M-LNCS DCIP) Compatible Pediatric Finger Clip SpO2 Sensor, Reusable, 3.3 ft (1.0 m)
The Masimo 2502 (M-LNCS DCIP) compatible SpO2 sensor (SKU SS-007RB-PF10) is a reusable, aftermarket replacement (not OEM) pediatric finger clip sensor for Masimo SET devices with an M-LNCS interface, built to match the original’s fit, form, and function.
| Sensor Type | Hard Shell Finger Clip |
| Patient Size | Pediatric, 22–110 lbs (10–50 kg) |
| Connector | Masimo M-LNCS |
| Cable Length | 3.3 ft (1.0 m) |
| Lifecycle | Reusable |
| Replaces | Masimo 2502, Physio-Control 11171-000047, Draeger MP02982, and more |
Works with: Physio-Control Lifepak 15, Biolight BLT A6, BLT A8, M8500, and Q-Series monitors, Masimo Radius-7, and Welch Allyn Connex Spot. On 20-pin Masimo devices, pair it with our compatible RC-8 M-LNCS patient cable. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for Masimo patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SS-007RB-PF10 |
| Replaces OEM Part | Masimo 2502 (M-LNCS DCIP) |
| Category | Reusable SpO2 Sensor |
| Sensor Type | Hard Shell Finger Clip |
| Patient Size | Pediatric |
| Patient Weight Range | 22–110 lbs (10–50 kg) |
| Cable Length | 3.3 ft (1.0 m) |
| Connector | Masimo M-LNCS (Requires M-LNCS Patient Cable) |
| SpO2 Technology | Masimo SET (M-LNCS) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Physio-Control (Stryker) | Lifepak 15 |
| Biolight | BLT A6, BLT A8, M8500, Q3, Q6, Q7 |
| Masimo | Radius-7 |
| Welch Allyn | 75MT-B Connex Spot |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 2502 (M-LNCS DCIP) |
| Comen | 040-000373-00 |
| Draeger | MP02982 |
| GE Healthcare | 2068423-062 |
| Physio-Control (Stryker) | 11171-000047 |
IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2502 M-LNCS DCIP SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Compatible Masimo 2502 M-LNCS DCIP SpO2 Sensor?
The Masimo 2502 (M-LNCS DCIP) compatible SpO2 sensor (IPR SKU SS-007RB-PF10) is a reusable pediatric finger clip sensor for Masimo SET-equipped devices that use the M-LNCS sensor interface. It is a compatible aftermarket replacement, not an OEM Masimo product, built to match the fit, form, and function of the original. The 3.3 ft (1.0 m) cable ends in an M-LNCS connector, which attaches to the monitor through an M-LNCS-compatible patient cable such as a Masimo rainbow RC-series or M-LNC cable. M-LNCS sensors are widely used on Physio-Control Lifepak 15 monitor/defibrillators, Biolight monitors, and the Masimo Radius-7, making this a common pediatric sensor for EMS crews. Note that M-LNCS and standard LNCS connectors are not interchangeable without an adapter.
Compatible Monitor Models
This compatible sensor works with the Physio-Control Lifepak 15; Biolight BLT A6, BLT A8, M8500, Q3, Q6, and Q7 monitors; the Masimo Radius-7; and the Welch Allyn Connex Spot 75MT-B. On devices with a 20-pin Masimo Red or rainbow port, the sensor connects through an M-LNCS patient cable. Confirm your device’s SpO2 interface and patient cable before ordering.
Design and Construction
The sensor uses a pediatric-sized hard shell finger clip with a spring hinge that holds the emitter and detector in consistent alignment across a child’s fingertip. The clip applies and removes quickly, making it well suited for pediatric spot checks in the field, the ED, and clinics. If a child needs extended continuous monitoring, a soft tip or adhesive sensor may be more comfortable. The sensor is sized for pediatric patients weighing approximately 22 to 110 lbs (10 to 50 kg). The 3.3 ft (1.0 m) cable terminates in an M-LNCS connector. The sensor is reusable and supplied one per bag.
When to Replace Your 2502 M-LNCS DCIP SpO2 Sensor
Finger clip sensors used in EMS and emergency settings take heavy handling, and wear shows up first at the hinge, the finger pads, and the connector. Replace the sensor when the clip no longer closes firmly, the finger pads are torn or hardened, the emitter or detector windows are scratched or discolored, the M-LNCS connector is cracked or damaged, or the cable jacket shows cuts or kinks. Persistent “sensor off” alarms or readings that drop out when the cable is moved also point to a failing sensor. Keeping a pediatric spare on each truck or crash cart prevents staff from having to improvise with an adult sensor.
Cross Reference and Interchange Part Numbers
This compatible sensor cross-references to Masimo 2502 (M-LNCS DCIP), and to the OEM-labeled equivalents sold under other monitor brands, including Comen 040-000373-00, Draeger MP02982, GE Healthcare 2068423-062, and Physio-Control 11171-000047.
Why Source Masimo-Compatible SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for infusion pumps and patient monitoring equipment. Compatible reusable SpO2 sensors give EMS agencies, pediatric units, and materials managers a cost-effective way to keep Masimo-equipped monitors and defibrillators in service without paying OEM pricing. We also stock compatible M-LNCS patient cables, so you can source the sensor and cable together. Our team can confirm fit against your device before you order, and we also offer in-house repair services, replacement parts, and refurbished equipment.
IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2502 M-LNCS DCIP SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.