Draeger 2870298 Compatible Neonatal NIBP Air Hose, Single-Tube Luer Slip, 8.2 ft (2.5 m)
$60.00The Draeger 2870298 compatible neonatal NIBP air hose (SKU BPH-NS25-18-06) is a reusable, aftermarket replacement (not OEM) designed for single-tube neonatal NIBP cuffs with male luer slip fittings, built to match the fit, form, and function of the original Draeger neonatal blood pressure hose.
Hose Type
Single-Tube Neonatal NIBP Air HosePatient Size
NeonateHose Length
8.2 ft (2.5 m)Monitor-End Connector
Draeger Mono PlugCuff-End Connector
Luer SlipLifecycle
ReusableReplaces
Draeger 2870298Works with: Draeger Infinity Delta, Infinity Gamma, Infinity Kappa, Infinity Vista, SC 6000, SC 7000, SC 8000, and SC 9000. Browse more NIBP hoses and accessories from IPR Medical.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger 3368391 Compatible MultiMed 5 Multi-Parameter Cable, 5-Lead ECG, Dual 7-Pin Aux Ports, 8.2 ft (2.5 m), AHA/IEC
$300.00The Draeger 3368391 compatible multi-parameter cable (SKU ETM-SM-E5ST) is a reusable, aftermarket replacement (not OEM) for the Draeger MultiMed 5 cable that combines a 5-lead ECG trunk with dual auxiliary connectors on a single cable, built to match the original’s fit, form, and function.
Cable Type
Multi-Parameter ECG Trunk Cable (Long Trunk)Lead Count
5 Leads (Supports 3-Lead Configuration)Color Code
AHA/IECCable Length
8.2 ft (2.5 m)Patient Size
Adult/PediatricLifecycle
ReusablePackaging
1 per BagReplaces
Draeger 3368391, 5950192Works with: select Draeger Infinity monitors, including the Delta, Gamma, Kappa, Vista, Omega S, C500, and C700, and the Draeger SC 6000, SC 7000, and SC 9000. See the Specifications tab for the full list. Browse more ECG/EKG cables and leadwires from IPR Medical.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger 3368433 Compatible SpO2 Adapter Cable, for Use with Nellcor OxiSmart Sensors, 3.9 ft (1.2 m)
$60.00The Draeger 3368433 compatible SpO2 adapter cable (SKU SA-028-12) is a reusable aftermarket replacement (not OEM) with a 3.9 ft (1.2 m) cable, for use with Nellcor OxiSmart sensors.
Cable Type
SpO2 Adapter CableSpO2 Technology
Nellcor OxiSmartCable Length
3.9 ft (1.2 m)Lifecycle
ReusablePackaging
1 per bagReplaces
Draeger 3368433Works with: select Draeger Infinity and SC models, such as the Infinity Delta, Infinity Vista, and SC 7000. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for Draeger monitoring equipment and SpO2 accessories. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger 3375834 Compatible SpO2 Adapter Cable, for Use with Nellcor OxiSmart Sensors, 7.9 ft (2.4 m)
$60.00The Draeger 3375834 compatible SpO2 adapter cable (SKU SA-028-24) is a reusable aftermarket replacement (not OEM) with a 7.9 ft (2.4 m) cable, for use with Nellcor OxiSmart sensors.
Cable Type
SpO2 Adapter CableSpO2 Technology
Nellcor OxiSmartCable Length
7.9 ft (2.4 m)Lifecycle
ReusablePackaging
1 per bagReplaces
Draeger 3375834Works with: select Draeger SC and Infinity models, including the SC 8000, SC 9000XL, and Infinity Gamma. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitors, SpO2 cables, and sensors. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger 5956441 / MS16233 Compatible 3/5-Lead ECG Leadwire, Siemens Dual-Pin, Snap, AHA, Molded, 3.0 ft (0.9 m)
$40.00The Draeger 5956441 / MS16233 compatible 3/5-lead ECG leadwire (SKU EL-SMB3-90S-A) is a reusable aftermarket replacement (not OEM) with snap electrode ends, limb lead placement, AHA color coding, a Siemens Dual-Pin lead type, and a 3.0 ft (0.9 m) length.
Lead Count
3/5-leadElectrode End
SnapLead Type
Siemens Dual-PinAHA/IEC Code
AHACable Length
3.0 ft (0.9 m)Replaces
Draeger 5956441 / MS16233Works with: select Draeger Infinity and SC models, plus select Fukuda Denshi, Kontron, and Skanray / Larsen & Toubro models and other brands. See the Specifications tab for the full list. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and ECG accessories. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger 5956458 / Siemens MS16229 Compatible 5-Lead ECG Leadwire, Snap, AHA, Molded, 3.0 ft (0.9 m)
$50.00The Draeger 5956458 / Siemens MS16229 compatible 5-lead ECG leadwire (SKU EL-SM5-90S-A) is a reusable aftermarket replacement (not OEM) with snap electrode ends, limb and chest lead placement, AHA color coding, and a 3.0 ft (0.9 m) length.
Lead Count
5-LeadLead Placement
Limb + Chest LeadElectrode End
SnapAHA/IEC Code
AHACable Length
3.0 ft (0.9 m)Replaces
Draeger 5956458 / Siemens MS16229Works with: select Draeger Infinity and SC models, plus select Kontron, Fukuda Denshi, and DRE models and other brands. See the Specifications tab for the full list. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and ECG accessories. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger MP00915 Compatible Reusable NIBP Cuff, Adult 25–35 cm, Single-Tube, Female Receptacle
$25.00The Draeger MP00915 compatible reusable NIBP cuff (SKU BPN-50BS-W44) is an aftermarket replacement (not OEM) for Draeger’s adult-size reusable blood pressure cuff, sized for limb circumferences of 9.8–13.8 in (25–35 cm).
Cuff Size
AdultLimb Circumference
9.8–13.8 in (25–35 cm)Tube Configuration
Single TubeTube Length
9.8 in (25 cm)Lifecycle
ReusablePackaging
1 per BagReplaces
Draeger MP00915Works with: Draeger patient monitoring equipment that uses the OEM MP00915 adult reusable cuff. Browse more NIBP cuffs, hoses, and accessories from IPR Medical.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger MP00953 Compatible NIBP Air Hose, Adult/Pediatric, Single-Tube, 12 ft (3.7 m)
$70.00The Draeger MP00953 compatible NIBP air hose (SKU BPH-AS37-18-43) is a reusable, aftermarket replacement (not OEM) for Draeger’s current adult NBP connecting hose, built to match the original’s fit, form, and function, for use with adult and pediatric single-tube NIBP cuffs.
Hose Type
Single-Tube NIBP Air HosePatient Size
Adult/PediatricHose Length
12 ft (3.7 m)Monitor-End Connector
Draeger Mono PlugCuff-End Connector
Bayonet Quick-DisconnectLifecycle
ReusableReplaces
Draeger MP00953, 1275 275 E07, 1275 275 EH5OUWorks with: Draeger Infinity Delta, Infinity Gamma, Infinity Kappa, and Infinity Vista monitors and the SC 6000, SC 7000, SC 8000, and SC 9000. Browse more NIBP hoses and accessories from IPR Medical.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger MP03402 Compatible 3-Lead ECG Leadwire, Grabber/Pinch, Molded, 3 ft (0.9 m), AHA
$50.00The Draeger MP03402 compatible 3-lead ECG leadwire (SKU EL-DG3-90G-A) is a reusable aftermarket replacement (not OEM) built to match the fit, form, and function of the original Draeger lead set, with three limb leads, pinch/grabber electrode clips, and AHA color coding for adult and pediatric monitoring.
Lead Count
3 LeadsLead Placement
Limb Leads (RA, LA, LL)Electrode End
Pinch/Grabber ClipColor Code
AHA (US)Leadwire Length
3 ft (0.9 m)Patient Size
Adult/PediatricLifecycle
ReusableReplaces
Draeger MP03402, MP03422, 2612001; Siemens MS16231Works with: Draeger Infinity M540, Infinity M300, MultiMed Plus, and MultiMed Plus OR. Browse more ECG/EKG cables and leadwires from IPR Medical.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger MP03404 Compatible 5-Lead ECG Leadwire, Grabber/Pinch, Molded, 3 ft (0.9 m), AHA
$60.00The Draeger MP03404 compatible 5-lead ECG leadwire (SKU EL-DG5-90G-A) is a reusable, aftermarket replacement (not OEM) lead set with pinch/grabber electrode clips and AHA color coding for adult and pediatric monitoring, built to match the fit, form, and function of the original Draeger lead set.
Lead Count
5 LeadsLead Placement
Limb + Chest (RA, LA, LL, RL, V)Color Code
AHAElectrode End
Pinch/Grabber ClipLeadwire Length
3 ft (0.9 m)Patient Size
Adult/PediatricLifecycle
ReusableReplaces
Draeger MP03404, MP03424, 2612003, Siemens MS16546Works with: the Draeger Infinity M540, Infinity M300, MultiMed Plus, and MultiMed Plus OR. Browse more ECG/EKG cables and leadwires from IPR Medical.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger MS14556 Compatible 3-Lead ECG Leadwire, Snap, Molded, 3 ft (0.9 m), AHA
$50.00The Draeger MS14556 compatible 3-lead ECG leadwire (SKU EL-DG3-90S-A) is a reusable, aftermarket replacement (not OEM) lead set with snap-style electrode connectors and AHA color coding for adult and pediatric monitoring, built to match the fit, form, and function of the original Draeger lead set.
Lead Count
3 LeadsColor Code
AHA (US): RA White, LA Black, LL RedElectrode End
SnapLeadwire Length
3 ft (0.9 m)Patient Size
Adult/PediatricLifecycle
ReusableReplaces
Draeger MS14556Works with: Draeger Infinity M540, Infinity M300, MultiMed Plus, and MultiMed Plus OR. Browse more ECG/EKG cables and leadwires from IPR Medical.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Draeger MS14560 Compatible 5-Lead ECG Leadwire, Snap, Molded, 3 ft (0.9 m), AHA
$60.00The Draeger MS14560 compatible 5-lead ECG leadwire (SKU EL-DG5-90S-A) is a reusable, aftermarket replacement (not OEM) for the Draeger MonoLead 5 single-pin lead set, built to match the original’s fit, form, and function.
Lead Count
5 LeadsElectrode End
SnapColor Code
AHA (US)Leadwire Length
3 ft (0.9 m), Limb and Chest LeadsPatient Size
Adult/PediatricLifecycle
ReusableReplaces
Draeger MS14560Works with: Draeger Infinity M540, Infinity M300, MultiMed Plus, and MultiMed Plus OR. Browse more ECG/EKG cables and leadwires from IPR Medical.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.