Skip to content
IPR Medical

Physio-Control 21300-008148 Compatible Adult/Pediatric NIBP Air Hose, 1-Tube, Male BP Plug, for 1-Tube Bayonet Cuffs

$40.00

The Physio-Control 21300-008148 compatible NIBP air hose (SKU BPH-TS-29-02M) is a reusable aftermarket replacement (not OEM) with a single tube and a male BP plug, for use with a 1-tube bayonet cuff on adult and pediatric patients.

Patient Size Adult/Pediatric
Tube Configuration 1-Tube (Single Tube)
BP Plug Male
Used with Cuff 1-Tube Bayonet Cuff
Lifecycle Reusable
Replaces Physio-Control 21300-008148

Works with: select Physio-Control, Zoll, Mindray / Datascope, Edan, and Criticare / CSI models, plus other brands. See the Specifications tab for the full list. Browse more NIBP hoses and accessories.

IPR Medical buys, sells, repairs, and stocks parts for blood pressure accessories and patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: physio-control-nibp-air-hose-21300-008148 Categories: , Tags: , Brand:
Send In Physio-Control 21300-008148 Compatible Adult/Pediatric NIBP Air Hose, 1-Tube, Male BP Plug, for 1-Tube Bayonet Cuffs for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) BPH-TS-29-02M
Replaces OEM Part Physio-Control 21300-008148
Category Cables & Sensors > NIBP
Hose Type BP Air Hose
Patient Size Adult/Pediatric
Tube Configuration 1-Tube (Single Tube)
BP Plug Male
Used with Cuff 1-Tube Bayonet Cuff
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Aspen V1
Bionet BMP300
Cardell 9403
Contec CMS 9000
Criticare / CSI 506, 506 Series, 506DN, 506DN3, 506DNB, 506DNP3, 506DNT3, 506DNTP3, 506DNV3, 506DNVP3, 506DXNT2, 506DXNTP2, 506LN3, 506LNP3, 506LNT3, 506LNTP3, 506LNV3, 506LNVP3, 506N3, 506NP3, 506NT3, 506NTP3, 506NV3, 506NVP3, 507, 507EL, 507EL(Scholar III), 507EL/C, 507ELC2, 507MPS, 507NJC, 8100 (Poet Plus), 8100 Series, 8100E Series (nGenuity), 8100H Series (nCompass), nGenuity
Datex-Ohmeda enGuard CM5
DRE Waveline EZ MAX
Edan Elite V5, F6 Express, F9, F9 Express, iM8, iM8A, iM8B, iM9, iM9A, iM50, iM60, iM60 VET, iM60GT, iM70, iM70 VET, iM80, iM80 VET, M3, M3A, M3B, M8, M8A, M8B, M9, M9A, M50, M80
Invivo MDE Escort Prism
Ivy Biomedical 450C, CM5
Medica D Logicare Series 2000
Mindray / Datascope Accutorr 3, Accutorr Plus, Accutorr V, DPM3, DPM 4, DPM 5, Duo, MEC 1000, MEC 1200, MEC 2000, Passport 2, Passport 2LT, Passport V, PM 5000, PM 6000, PM 7000, PM 7000 Standard, PM 8000, PM 8000 Express, PM 9000, PM 9000 Express, Spectrum OR, T5, Trio, V12, V21, V-Series, XG
Philips 78332A, 862146, M3
Physio-Control Lifepak 15
Smiths Medical / BCI 9200(Advisor), Mini Torr
Spacelabs 90369
Sunnex M8000A
Zoll E Series, M Series, X Series

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Physio-Control 21300-008148, 21300-007299, 21300-007298, 21300-007300
Unimed HTS-44-15

IPR Medical buys, sells, repairs, and stocks parts for NIBP air hoses and the patient monitoring equipment they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Physio-Control, Philips, Invivo, or any other manufacturer or supplier named on this page. Physio-Control, Philips, Invivo, Lifepak, Escort, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Physio-Control 21300-008148 Compatible NIBP Air Hose?

The IPR Medical BPH-TS-29-02M is a compatible aftermarket (not OEM) NIBP air hose that replaces the Physio-Control 21300-008148. It is a reusable single-tube hose for adult and pediatric patients, fitted with a male BP plug and used with 1-tube bayonet cuffs. Talk with our team to confirm hose length and fit for your setup before you order.


Compatible Monitor Models

Within the OEM’s own line, the Physio-Control Lifepak 15 is on the compatibility list, and select Zoll models such as the X Series are listed as well. The list continues with select Mindray / Datascope models such as the Accutorr Plus, Passport 2, and PM 8000 Express, select Edan models including the iM60 and M50, and select Criticare / CSI models like the 506DN3 and 8100E Series (nGenuity). Select Smiths Medical / BCI, Ivy Biomedical, Spacelabs, and Bionet models, together with the remaining brands, are shown in the Compatible Monitor Models table on the Specifications tab.


Design and Construction

One tube makes up this hose. It carries a male BP plug and is specified for the 1-tube bayonet cuffs used on adult and pediatric patients. The hose is reusable and comes one per bag; clean it between patients according to your facility protocol.


When to Replace Your Physio-Control Compatible NIBP Hose

Pull the hose from service when its tubing shows kinks that stay put, scuffed or thinned areas, or splits, or when a fitting cracks or no longer holds a seal. In daily use, persistent leak messages, slow inflation, and readings that take several attempts are typical clues. Pair the same cuff and monitor with a hose you know is good to confirm where the air is escaping before you reorder.


Cross Reference and Interchange Part Numbers

Along with the Physio-Control 21300-008148 it replaces, this hose cross-references to Physio-Control 21300-007298, 21300-007299, and 21300-007300. A single aftermarket equivalent is also on record, and the Specifications tab’s Cross Reference / Interchange Part Numbers table lists it next to those OEM numbers.


Why Source NIBP Air Hoses from IPR Medical?

IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps, and this Physio-Control compatible hose is one of them. As an ISO 9001:2015-certified independent service organization, the company handles repair work in-house with its own technicians. Our team is at 855-477-8866, and more NIBP hoses and accessories are in the catalog.

IPR Medical buys, sells, repairs, and stocks parts for NIBP air hoses and the patient monitoring equipment they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Physio-Control, Philips, Invivo, or any other manufacturer or supplier named on this page. Physio-Control, Philips, Invivo, Lifepak, Escort, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.