Draeger MS24303 Compatible SpO2 Adapter Cable, for Use with Masimo LNCS Sensors, 3.9 ft (1.2 m)
The Draeger MS24303 compatible SpO2 adapter cable (SKU SA-028RB-12LS) is a reusable aftermarket replacement (not OEM) with a 3.9 ft (1.2 m) cable, for use with Masimo LNCS sensors.
| Cable Type | SpO2 Adapter Cable |
| SpO2 Technology | Masimo LNCS |
| Cable Length | 3.9 ft (1.2 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
| Replaces | Draeger MS24303 |
Works with: select Draeger Infinity models, for example the Infinity Kappa and Infinity Vista. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for Draeger patient monitors and SpO2 accessories. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SA-028RB-12LS |
| Replaces OEM Part | Draeger MS24303 |
| Category | Cables & Sensors > SpO2 |
| Cable Type | SpO2 Adapter Cable |
| SpO2 Technology | Masimo LNCS |
| Used With | Masimo LNCS sensors |
| Cable Length | 3.9 ft (1.2 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Draeger | Infinity Delta, Infinity Gamma, Infinity Kappa, Infinity MultiMed Pod, Infinity Vista |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Draeger | MS24303 |
| Unimed | U704M-23R |
IPR Medical buys, sells, repairs, and stocks parts for SpO2 accessories and Draeger patient monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Draeger, Masimo, or any other manufacturer or supplier named on this page. Draeger, Masimo, LNCS, Infinity, MultiMed, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Draeger MS24303 Compatible SpO2 Adapter Cable?
The IPR Medical SA-028RB-12LS is a compatible aftermarket (not OEM) SpO2 adapter cable that replaces the Draeger MS24303. It is a reusable 3.9 ft (1.2 m) adapter for use with Masimo LNCS sensors, listed for the Draeger models shown on the Specifications tab.
Compatible Monitor Models
For this part, the compatible list is made up of select Draeger Infinity models: Infinity Vista, Infinity Kappa, Infinity Gamma, Infinity Delta, and the Infinity MultiMed Pod. That list matches the Compatible Monitor Models table on the Specifications tab; use the table to confirm the model printed on your equipment.
Design and Construction
Intended for use with Masimo LNCS SpO2 technology, the SA-028RB-12LS has a 3.9 ft (1.2 m) cable. It is packed one per bag and is reusable. Clean the adapter in line with your facility’s protocol, and check the jacket and connector ends for damage before connecting it again.
When to Replace Your SpO2 Adapter Cable
Look for a jacket that has split or stiffened, cracks in either connector body, and crush damage from bed rails or equipment wheels. Functionally, gaps in the saturation trend, sensor-fault alarms, and readings that shift whenever the adapter is moved suggest it should be replaced. Swapping in a second adapter known to be good will show whether the cable is the cause.
Cross Reference and Interchange Part Numbers
Draeger MS24303 is the OEM part number this adapter replaces. Its one aftermarket counterpart appears in the row beneath that number in the cross-reference table on the Specifications tab.
Why Source SpO2 Adapter Cables from IPR Medical?
Parts for patient monitors and infusion pumps, this adapter included, are bought, sold, repaired, and stocked by IPR Medical. When a repair is needed, IPR Medical’s own technicians do the work in-house, and the company holds ISO 9001:2015 certification as an independent service organization. For pricing or other questions, call 855-477-8866 or look through our SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for SpO2 accessories and Draeger patient monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Draeger, Masimo, or any other manufacturer or supplier named on this page. Draeger, Masimo, LNCS, Infinity, MultiMed, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.



















