Alaris BD 8300 EtCO2 Module
The Alaris 8300 EtCO2 Module brings continuous capnography onto the Alaris System. It attaches to an Alaris PC Unit (Model 8015) like an infusion module and uses Microstream™ sidestream capnography to monitor end-tidal CO2 (EtCO2), fractional inspired CO2 (FiCO2), and respiratory rate, with audible and visual alarms for high and low EtCO2 and respiratory rate, high FiCO2, no breath, and disposable or system faults.
Its biggest clinical value is pairing with the Alaris 8120 PCA Module: with BD’s optional PCA pause protocol enabled, the PCA infusion pauses and alarms when a hospital-defined low respiratory rate limit is exceeded and sustained. Respiratory monitoring and opioid PCA run from one PC Unit, one interface, and one pole position.
Also available: BD Alaris 8015 PC Unit (v12.3 Software)
Brand new units may be available — contact us for details. IPR Medical buys, sells, repairs, and stocks parts for the Alaris 8300 EtCO2 Module. Call us at 855-477-8866 or email cs@iprmed.com.
Rx only. Sold to healthcare facilities, licensed practitioners and equipment service providers; not sold to patients for home use (Terms §8).
Alaris 8300 EtCO2 Module — Specifications
| Manufacturer | BD (Becton, Dickinson and Company) / CareFusion |
| Model | Alaris EtCO2 Module, Model 8300 |
| System Platform | BD Alaris System with Guardrails Suite MX; requires an Alaris PC Unit (Model 8015) |
| Intended Use | Capnograph for continuous, noninvasive monitoring of end-tidal CO2 (EtCO2), fractional inspired CO2 (FiCO2), and respiratory rate |
| Technology | Microstream™ sidestream capnography using Microstream FilterLine™ disposables (adult/pediatric sets and FilterLine H sets for infant/neonatal use) |
| Measurement Range | EtCO2: 0 – 99 mmHg; FiCO2: 0 – 99 mmHg; respiratory rate: 0 – 150 bpm |
| CO2 Accuracy | ±2 mmHg from 0 – 38 mmHg at sea level; accuracy above 38 mmHg and at breath rates above 80 bpm per BD labeling (FilterLine H set required for specified accuracy above 60 breaths/min) |
| Respiratory Rate Accuracy | 0 – 70 bpm: ±1 bpm; 71 – 120 bpm: ±2 bpm; 121 – 150 bpm: ±3 bpm |
| Alarm Limits | EtCO2 low 0 – 98 mmHg, high 5 – 99 mmHg; FiCO2 high 2 – 99 mmHg; no breath 10 – 60 sec; respiratory rate low 0 – 149, high 1 – 150 breaths/min |
| Alarms | High and low EtCO2 and respiratory rate, high FiCO2, Microstream disposable condition, system failure, no breath, and low battery |
| Sampling Flow Rate | Nominally 50 ml/min (+15 / −7.5 ml/min) |
| Response Time | 4.9 seconds typical (includes rise time of 260 msec maximum) |
| Warm-Up Time | 30 seconds typical |
| Waveform Sampling | 20 samples per second |
| Barometric Pressure | Automatic barometric pressure compensation |
| Gas Interference | Desflurane, enflurane, halothane, isoflurane, and sevoflurane tested with no effect |
| PCA Pause Protocol | Supports BD’s optional PCA pause protocol with the Alaris 8120 PCA Module (pauses PCA when the defined low respiratory rate limit is exceeded and sustained) |
| Power | Powered through the Alaris PC Unit; BD lists about 4 hours of PC Unit battery runtime with one active EtCO2 Module (new, fully charged battery) |
| Shock Protection | Type BF |
| Fluid Ingress Protection | IPX2 (Drip Proof) |
| Operating Environment | 41 – 104°F; 20 – 90% relative humidity (noncondensing); 525 – 795 mmHg |
| Storage / Transport | −4 – 140°F; 5 – 90% relative humidity (noncondensing); 375 – 760 mmHg |
| Mode of Operation | Continuous |
| Dimensions | 3.3″ W × 8.9″ H × 5.5″ D (8.4 cm × 22.6 cm × 14 cm) |
| Weight | 2.5 lbs (1.13 kg) |
| Purchase Scope | Includes: one recertified Alaris 8300 EtCO2 Module. Not included: Alaris PC Unit and Microstream FilterLine sampling disposables |
| FDA Device Corrections | Class 2 IUI connector correction (August 2024, Z-3140-2024); earlier 2020 FDA records for the 8300 remain listed as open — see the Description tab and contact IPR Medical at 855-477-8866 for current guidance |
IPR Medical buys, sells, repairs, and stocks parts for the Alaris 8300 EtCO2 Module. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: BD, Microstream, FilterLine, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by BD.
Quick answer: The Alaris 8300 EtCO2 Module is the capnography module of the Alaris System. It attaches to an Alaris PC Unit (Model 8015) and uses Microstream sidestream capnography to monitor EtCO2, FiCO2, and respiratory rate, and it can drive BD’s PCA pause protocol with the Alaris 8120 PCA Module. IPR Medical sells recertified 8300 modules backed by IPR Medical’s warranty, repairs them in-house, and stocks parts.
Overview
The Alaris 8300 EtCO2 Module is a capnograph that provides continuous, noninvasive monitoring of end-tidal carbon dioxide (EtCO2), fractional inspired carbon dioxide (FiCO2), and respiratory rate. It attaches to an Alaris PC Unit (Model 8015) alongside the facility’s infusion modules, shows EtCO2 and respiratory rate on the module’s own display, and uses the PC Unit for setup, alarm limits, and power. Status indicators show alarm (red), monitoring (green), and standby (yellow), and a Monitor key starts patient monitoring.
Microstream Capnography and Accuracy
The 8300 samples gas through Microstream FilterLine disposables at a nominal 50 ml/min and reports CO2 partial pressures from 0 to 99 mmHg, calculating EtCO2 and FiCO2 for every valid breath. BD specifies ±2 mmHg accuracy from 0 to 38 mmHg at sea level and respiratory rate accuracy of ±1 bpm up to 70 bpm, ±2 bpm from 71 to 120 bpm, and ±3 bpm from 121 to 150 bpm. For breath rates above 60 per minute, BD requires the Microstream FilterLine H set for infant/neonatal use to achieve the specified accuracy. The module compensates automatically for barometric pressure, runs a periodic auto zero to prevent drift, and warms up in about 30 seconds.
PCA Pause Protocol with the 8120 PCA Module
When a facility enables BD’s optional PCA pause protocol and the 8300 is attached and monitoring, an Alaris 8120 PCA Module on the same PC Unit pauses its infusion and alarms when the hospital-defined low respiratory rate limit is exceeded and sustained. Without an EtCO2 Module attached and started, the protocol does not activate. For facilities running opioid PCA, this puts respiratory monitoring and PCA delivery under one interface and one set of Guardrails rules.
Use Precautions
BD states that the EtCO2 Module is not intended for use with high-frequency surgical equipment such as electrocautery devices, and that the module and Microstream disposables should not be used inside a hyperbaric chamber. Inaccurate readings or loss of the respiratory rate signal can result from incorrect disposable use, a disconnected or loose disposable, a clogged, twisted, or leaking airway connection, or placement near electrocautery equipment. Leaks or internal venting of sampled gas can also affect accuracy, and BD directs any device whose accuracy is in doubt to biomedical engineering.
FDA Device Corrections and Safety Bulletins
The following FDA-listed action includes the Alaris EtCO2 Module 8300.
1. Class 2 Correction (August 2024, Z-3140-2024) — IUI Connectors: BD identified an increase in bent contacts on the new female (left) IUI connectors, which can make a module inoperable and delay the start of monitoring. The FDA record lists specific serial numbers. BD instructs users to inspect all IUI connectors before use and to send any module with a bent or lifted pin to biomedical engineering or qualified service personnel.
Earlier 2020 FDA records for the 8300, covering dim LED display segments and a component defect that could interrupt monitoring, are also listed as open in the FDA recall database.
Action recommended: Inspect both IUI connectors before use, confirm the module’s display segments are fully lit during check-in, and check each serial number against BD’s open notices. IPR Medical can assist with inspection, repair, and parts — call 855-477-8866 or email cs@iprmed.com.
Because FDA device corrections and safety communications may be updated or expanded after the date of this listing, IPR Medical recommends that facilities also check the FDA’s official resources directly to ensure they have the most current information:
IPR Medical — Your Source for the Alaris 8300 EtCO2 Module
IPR Medical buys, sells, repairs, and stocks parts for the Alaris 8300 EtCO2 Module. Whether you are adding capnography to PCA therapy, expanding an existing Alaris fleet, or need service on modules you already own, our team can help you match modules and software to what your facility runs.
IPR Medical buys, sells, repairs, and stocks parts for the Alaris 8300 EtCO2 Module. Contact us at 855-477-8866 or cs@iprmed.com.
Frequently asked questions
Does the 8300 work on its own?
No. It attaches to an Alaris PC Unit (Model 8015), which provides setup, alarm limits, and power. See our BD Alaris 8015 PC Unit (v12.3 Software) and 5.7-inch PC Unit listings.
What does the 8300 measure?
EtCO2 and FiCO2 from 0 to 99 mmHg and respiratory rate from 0 to 150 breaths per minute, using Microstream sidestream capnography.
Which sampling disposables does it use?
Microstream FilterLine disposables. BD specifies the FilterLine H set for infant/neonatal use to achieve rated accuracy at breath rates above 60 per minute. Sampling disposables are not included with the module.
Can IPR Medical repair our Alaris EtCO2 Modules?
Yes. IPR Medical repairs Alaris EtCO2 Modules in-house. U.S. customers can request a free inbound FedEx or UPS shipping label through our RMA form, receive a free evaluation within 1 to 2 business days, and approve a written estimate before work begins. Repaired modules are tested to OEM specifications, cleaned, and carry a 90-day warranty.
Repair service: IPR Medical also repairs BD Alaris pumps in house, with a free shipping label, a free evaluation and a 90-day repair warranty. See BD Alaris pump repair.
Trademark Notice: BD, Microstream, FilterLine, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by BD.
| Weight | 7.2 lbs |
|---|---|
| Dimensions | 8.8 × 6.9 × 8.8 in |
- IUI Connector
Reviews
There are no reviews yet.