Baxter Auto Syringe AS40A Infusion Pump
The Baxter Auto Syringe AS40A is a compact, single-channel syringe infusion pump designed for accurate continuous or intermittent delivery of fluids and medications. It supports IV, intra-arterial, epidural, and subcutaneous routes, accepts standard disposable syringes from 1 mL to 60 mL across three manufacturers, and operates on internal rechargeable battery or AC charger for bedside, transport, and ambulatory use.
| Pump Type | Single-channel syringe infusion pump |
| Flow Rate Range | 0.01 to 360 mL/hr (syringe-dependent) |
| Compatible Syringes | B-D Plastipak, Monoject, and Terumo, 1–60 mL |
| Battery | Internal NiCd rechargeable pack; 12 hr at 2 mL/hr (60 mL syringe) |
| Notable Features | Bolus, titration, auto syringe recognition, auto-lock, configurable occlusion sensitivity |
Looking for a newer alternative? Consider upgrading to the Baxter AS50 — the direct next-generation successor sharing the same compact form factor and syringe compatibility, with an extended flow rate ceiling of 438 ml/h and an upgraded rechargeable battery — or the Medfusion 3500 Version 6, a modern syringe pump with a built-in drug library options and full third-party service support.
Please note: Baxter has ended manufacturer support for the AS40A. IPR Medical buys, sells, and repairs the Baxter AS40A and stocks replacement parts to keep these pumps performing reliably in the field. Contact us at 855-477-8866 or cs@iprmed.com.
Baxter AS40A Syringe Pump — Specifications
Baxter has ended manufacturer support for this device; IPR Medical provides sales, repair, and replacement parts.
| Pump Type | Syringe infusion pump — continuous and intermittent |
| Infusion Modes | Continuous; intermittent (timed single or multiple equal doses); pre-programmable bolus; titration without flow interruption — all field configurable |
| Routes of Administration | Intravenous (IV), intra-arterial (IA), epidural, subcutaneous |
| Compatible Syringe Brands | Becton Dickinson (BD Plastipak), Monoject, Terumo — 1 mL to 60 mL |
| Flow Rate Range | 0.01 ml/h (1 mL syringe) to 360 ml/h (60 mL syringe) — varies by syringe size and rate range configuration |
| Flow Accuracy | ±3% (not including syringe tolerance); ±0.1 mL for bolus infusions under 3 mL (not including syringe tolerance) |
| Deliverable Volume | Full syringe volume programmable; VTBI programmable with volume limit alarm |
| Programming Modes | ml/h, ml/min, units/h, units/min, mUnits/h, mUnits/min, mg/h, mg/min, mcg/h, mcg/min — with optional drug library (drug-specific parameters stored in memory) |
| Data Display | Self-prompting, multi-field LCD — displays syringe manufacturer and size, infusion rate, body weight, concentration, next dose, total volume limit, and total volume delivered |
| Status Display | Nine-LED array |
| Keyboard | Numeric keypad, elastomeric with tactile feedback; configurable auto-lock |
| Alarms & Alerts | Line occluded, empty, volume limit, dose due, dose complete, near empty, low battery, near volume limit, bad battery, power fault, system failsafe |
| Occlusion Detection | Variable occlusion pressure sensitivity — field configurable |
| Power Supply | AC: 105–125V, 60 Hz (battery charger); DC: internal nickel-cadmium rechargeable battery pack |
| Battery Life | Approx. 12 hours at 2 ml/h using a 60 mL syringe following a 16-hour charge |
| Operating Temperature | 32°F to 113°F (0°C to 45°C); delivery of high-viscosity fluids at low temperatures not recommended |
| Dimensions | Approx. 3.4″ W × 2.6″ D × 10″ H (8.6 × 6.7 × 25 cm) |
| Weight | Approx. 2.75 lbs (1.25 kg) |
| Construction | High-impact plastic case with removable elastomeric protective bumpers; water resistant |
| Mounting | Built-in pole clamp and lanyard loop; tabletop capable |
| Connectivity | Optional RS-232 serial port (9-pin) for remote computer control and monitoring |
| Safety Standards | UL 544, UL 1310, ANSI/NFPA 99; meets AAMI ID-P Standards for Infusion Devices; meets MDS-201-0004 EMI/EMS requirements |
| Manufacturer Support Status | Baxter has ended manufacturer service for this device. Third-party service and parts available through IPR Medical. |
| FDA Device Corrections | A Class 2 device recall has been recorded for the AS40 and AS40A series. See Tab 2 for details and FDA resource links. Contact IPR Medical for guidance. |
IPR Medical buys, sells, repairs, and stocks parts for the Baxter AS40A. Contact us at 855-477-8866 or cs@iprmed.com.
What Our Customers Say
“I’ve been using IPR (Infusion Pump Repair) for about five years, and their service has been consistently outstanding. The team is incredibly knowledgeable and stands behind all their work. They respond quickly and make the repair process for our equipment, particularly our Baxter AS40 and AS50 pumps, seamless and hassle-free. The staff is always friendly, helpful, and super responsive. I highly recommend their services to anyone in need of reliable equipment repair and maintenance.”
— Jeremy J., Google review
Read more customer testimonials
Trademark Notice: Baxter, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Baxter.
Overview
The Baxter Auto Syringe AS40A is a compact, field-configurable syringe infusion pump designed to meet the precise fluid and drug delivery demands of clinical environments including anesthesia, critical care, pain management, chemotherapy, and neonatal or pediatric therapy. It supports continuous and intermittent infusion via intravenous, intra-arterial, epidural, and subcutaneous routes, accepting standard disposable syringes from 1 mL to 60 mL across Becton Dickinson, Monoject, and Terumo brands. At approximately 2.75 lbs with a built-in pole clamp and lanyard loop, the AS40A was engineered for flexible deployment at the bedside or on an IV pole — making it a workhorse pump across a wide range of acute care settings.
Infusion Modes and Programming
The AS40A supports continuous infusion as well as intermittent delivery of one or more equal timed doses, pre-programmable bolus operation, and dose titration without interruption of fluid flow. Programming is guided by a self-prompting multi-field LCD that walks the clinician through each field in sequence — syringe size and manufacturer, infusion rate, concentration, and volume limit — reducing the potential for entry errors. The pump programs in ml/h, ml/min, units/h, units/min, mUnits/h, mUnits/min, mg/h, mg/min, mcg/h, and mcg/min, with an optional on-board drug library that stores drug-specific infusion parameters in memory for faster, safer setup. A nine-LED status array provides at-a-glance infusion status throughout the therapy.
Field Configuration and Safety Features
One of the AS40A’s defining strengths is its field-configurable architecture, which allows biomedical technicians to tailor the pump’s behavior to the institution’s clinical protocols. Configurable options include available syringe brands and sizes, automatic syringe size recognition, selectable infusion modes, maximum rate ceiling, variable occlusion pressure sensitivity, and keypad auto-lock. This flexibility makes the AS40A adaptable across different care settings within the same facility. The comprehensive alarm system covers line occlusion, syringe empty, volume limit reached, near-empty warning, low battery, dose due and dose complete notifications, and a suite of failsafe alarms including bad battery, power fault, and system error — ensuring that any interruption to therapy is immediately flagged.
Power and Portability
The AS40A operates on its internal nickel-cadmium rechargeable battery pack, delivering approximately 12 hours of runtime at 2 ml/h using a 60 mL syringe after a full 16-hour charge, or can be operated continuously while the battery charger is connected to AC power (105–125V, 60 Hz). The pump’s high-impact plastic housing with removable elastomeric bumpers and water-resistant construction provides durability for demanding clinical environments. The built-in pole clamp and lanyard loop allow flexible IV pole mounting, while the flat base supports tabletop use. An optional RS-232 serial port (9-pin) enables remote computer monitoring and control for facilities utilizing centralized infusion management systems.
FDA Device Corrections and Safety Bulletins
The FDA has recorded a Class 2 device recall for the Baxter Auto Syringe AS40 and AS40A Infusion Pumps series (FDA recall ID 44130). A Class 2 recall designation indicates that use of the affected device may cause temporary or reversible adverse health consequences, or that the probability of serious harm is remote. Because the AS40A is a legacy device for which Baxter has ended manufacturer service, facilities currently operating AS40A pumps should verify the recall status and any recommended corrective actions directly through the FDA’s official databases. IPR Medical strongly recommends that all facilities check for the most current information using the FDA resources listed below.
Important safety note: Facilities using the Baxter AS40A should verify the current recall status and any required actions against the FDA Medical Device Recalls Database. Because Baxter has ended manufacturer service for this model, IPR Medical can assist with pump inspection, repair, and evaluation. Contact us at 855-477-8866 or cs@iprmed.com.
FDA official resources for current correction and recall information:
Because FDA device corrections and safety communications may be updated or expanded after the date of this listing, IPR Medical recommends that facilities also check the FDA’s official resources directly to ensure they have the most current information.
Considering an Upgrade?
Because Baxter has ended manufacturer support for the AS40A, some facilities may prefer to transition to a currently supported platform. The Baxter AS50 is the direct next-generation successor — sharing the same compact form factor, syringe compatibility, and intuitive keypad interface, while offering an extended flow rate ceiling of 438 ml/h and an upgraded rechargeable battery. For facilities seeking a more modern platform with a optional built-in drug libraries, and pharmguard safety software, the Medfusion 3500 Version 6 is a strong alternative. IPR Medical stocks, sells, and supports both platforms.
IPR Medical — Your Source for the Baxter AS40A
IPR Medical buys, sells, and repairs the Baxter AS40A and maintains an inventory of replacement parts to keep these pumps performing accurately in the field. Whether you need a refurbished unit, a specific component, or a full repair evaluation, our team has the experience and parts inventory to support your AS40A fleet. We also carry the AS50 and Medfusion 3500 V6 for facilities ready to upgrade.
IPR Medical buys, sells, repairs, and stocks parts for the Baxter AS40A. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: Baxter, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Baxter.
| Weight | 5 lbs |
|---|---|
| Dimensions | 14 × 10 × 10 in |
| Product Condition | Refurbished / Patient Ready |
Compatible Parts and Accessories
IPR Medical stocks a range of compatible parts and accessories for the Baxter Auto Syringe AS40A Infusion Pump. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.
Compatible Syringes
| B-D Plastipak Syringes | 1, 3, 5, 10, 20, 30, and 60 mL Plastipak disposable syringes; OEM-supported manufacturer; specific size enabled in pump configuration. |
| Monoject Syringes | 1, 3, 6, 12, 20, 35, and 60 mL disposable syringes; OEM-supported manufacturer; note 6/12/35 mL sizes (not 5/10/30) per Monoject sizing. |
| Terumo Syringes | 1, 3, 5, 10, 20, 30, and 60 mL disposable syringes; OEM-supported manufacturer. |
IV Extension Sets
| High-Flow IV Extension Set, 60 in (1M8521) | 60-inch high-flow IV extension set referenced in the AS40A Technical Manual calibration procedure; OEM P/N 1M8521. |
| Additional Compatible Extension Sets | The AS40A Operator’s Manual identifies additional Baxter-recommended IV extension sets in micro-volume, high-flow, and 0.22 µm filtered configurations across multiple lengths. Contact IPR Medical for the specific OEM catalog number matching your length, configuration, and filtration requirement. |
Power and Battery
| Battery Stack Assembly | Internal rechargeable nickel-cadmium battery pack; per the OEM Technical Manual, the pack is acceptable when it can sustain 5 V or greater after 19 hours of discharge through a 135 ohm load. OEM reference AAS40-01-533. |
| Battery Cover | Replacement battery hatch cover; OEM reference DAS40-01-483. |
| Battery Cover Screws (set of 3) | Three retaining screws for the battery cover; OEM reference S0232-03-663. |
| “900 Series” AC Battery Charger (CAS40-01-900) | Standard wall-mount AC charger; rated 115 VAC, 125 mA, 60 Hz; 8-pin Mini-DIN output. The AS40A is restricted to “900 Series” chargers and approved accessories per the OEM Technical Manual. OEM model number CAS40-01-900. |
Field-Replaceable Units (FRU)
| Barrel Clamp Assembly | External barrel clamp assembly that secures the syringe barrel and provides barrel-diameter sensing for syringe recognition. Held to the case by three screws and a locating boss. Requires Barrel Clamp Label BAS40-01-038. OEM reference AAS40-01-518. |
| Barrel Clamp Label | Replacement label paired with the Barrel Clamp Assembly; OEM reference BAS40-01-038. |
| Barrel Clamp Zebra Strip | Flexible zebra-strip electrical connector that seats between the barrel clamp assembly and the pump body; metallic strips face toward the top of the pump. OEM reference BAS40-01-487. |
| Barrel Clamp Assembly Screws (set of 3) | Three Phillips-head screws that retain the barrel clamp assembly to the case; OEM reference S0440-08-614. |
| Upper Plunger Assembly | Outer portion of the plunger driver assembly; field-replaceable by removing the lever pin. Requires Upper Plunger Assembly Label BAS40-01-012. OEM reference AAS40-01-501. |
| Upper Plunger Assembly Label | Replacement label paired with the Upper Plunger Assembly; OEM reference BAS40-01-012. |
| Lever Pin, Plunger Assembly | Replacement lever pin used to retain the Upper Plunger Assembly; OEM reference BAS40-01-422. |
| Top Case | Replacement top case (front housing); OEM reference AAS40-01-001 (per the AS40A Technical Manual replacement parts list). |
| Back Case | Replacement back case; OEM reference DAS40-01-097675 (per the AS40A Technical Manual replacement parts list). |
| Back Case Label | Replacement back case label; OEM reference BAS40-01-040 (per the AS40A Technical Manual replacement parts list). |
Bumpers, Pole Clamp, and Mounting
| End Cap (Bumper) Kit, Grey — Standard | Removable elastomeric protective bumper kit (top + bottom + instructions) in grey, the OEM standard color; OEM reference AAS40-01-491. |
| End Cap (Bumper) Kit, Blue | Same OEM bumper kit in blue (commonly used for color-coding by department or unit); OEM reference AAS40-02-491. |
| End Cap (Bumper) Kit, Green | Same OEM bumper kit in green; OEM reference AAS40-03-491. |
| End Cap (Bumper) Kit, Orange | Same OEM bumper kit in orange; OEM reference AAS40-04-491. |
| End Cap (Bumper) Kit, Black | Same OEM bumper kit in black; OEM reference AAS40-05-491. |
| Pole Clamp | Removable IV pole clamp; supports both vertical and horizontal pole orientations (jaw rotates 90° to fit horizontal poles). OEM reference A-AS40-01-515. |
Calibration Test Fixtures and Service Tooling
| Drive Position Calibration Fixture (CAS40-01-801) | “Syringe-full” drive position calibration fixture that verifies the 2.798 in driver-to-cradle distance per the OEM Technical Manual; OEM reference CAS40-01-801. |
| Drive Position Calibration Fixture (CAS40-02-801) | “Syringe-empty” drive position calibration fixture that verifies the 0.672 in driver-to-cradle distance per the OEM Technical Manual; OEM reference CAS40-02-801. |
| Syringe Recognition Calibration Fixture (CAS40-03-801) | Large-syringe (0.742 in) barrel-clamp calibration fixture for the Syringe Recognition system; OEM reference CAS40-03-801. |
| Syringe Recognition Calibration Fixture (CAS40-04-801) | Small-syringe (0.291 in) barrel-clamp calibration fixture for the Syringe Recognition system; OEM reference CAS40-04-801. |
| Additional Barrel Clamp Calibration Fixtures (CAS40-05-801, CAS40-06-801) | Additional fixtures in the OEM CAS40-XX-801 calibration set (-05- and -06-); OEM references CAS40-05-801 and CAS40-06-801. |
| Load Yoke for 10 lb Pressure Sensor Calibration (CAS40-01-802) | Load yoke used with cable and weights to perform the 10 lb pressure-sensor calibration step; OEM reference CAS40-01-802. |
Service and Documentation
| Charger / Serial Cable (8-Pin Mini-DIN) | 8-pin Mini-DIN cable used at the AS40A charger port for the “900 Series” charger interface and the pump’s serial communication. Pinout documented in the OEM Technical Manual. Contact IPR Medical for the specific cable specification matching your application. |
| Operator’s and Technical Manuals | Auto Syringe AS40A Infusion Pump Operator’s Manual and Technical Manual (LAS40-01-701). The Technical Manual covers software revisions A002P002 and A003P003; later software versions are documented in subsequent revisions. Contact IPR Medical for assistance locating archived OEM documentation. |
IPR Medical buys, sells, repairs, and stocks parts for the Baxter Auto Syringe AS40A Infusion Pump. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Reviews
There are no reviews yet.