IPR Medical

GE Healthcare 2106389-001 / 412681-001 Compatible 5-Lead Multi-Link ECG Leadwire, Grabber/Pinch, Molded, 3 ft (0.9 m), AHA

$50.00

The GE Healthcare 2106389-001 compatible 5-lead ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s Multi-Link 5-lead grabber set (also sold as 412681-001), built to match the original’s fit, form, and function.

Leads 5 (RA, LA, LL, RL, V)
Trunk-End Connector GE Multi-Link, Molded
Patient-End Connector Grabber/Pinch Clips
Lead Length 3 ft (0.9 m)
Color Code AHA (US)
Patient Size Adult/Pediatric
Construction Shielded, Reusable, Latex-Free

Works with: GE CARESCAPE B450, B650, and B850; Dash 3000, 4000, and 5000; Solar 8000 and 9500; Tram modules; ApexPro CH; Datex-Ohmeda Aestiva/5 and Unity; and more. See the Specifications tab for the full list. Browse more ECG/EKG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: EL-MQ5-90G-A Categories: , Tags: , ,
Send In GE Healthcare 2106389-001 / 412681-001 Compatible 5-Lead Multi-Link ECG Leadwire, Grabber/Pinch, Molded, 3 ft (0.9 m), AHA for Repair
Product Type Compatible Replacement (Aftermarket, Not OEM)
IPR Medical SKU EL-MQ5-90G-A
OEM Reference GE Healthcare 2106389-001 / 412681-001
Lead Type GE Multi-Link
Lead Count 5 Leads
Lead Placement Limb + Chest (RA, LA, LL, RL, V)
Color Code AHA (US): RA White, LA Black, LL Red, RL Green, V Brown
Trunk-End Connector GE Multi-Link, Molded
Patient-End Connector Grabber/Pinch Clip (Grouped)
Leadwire Length 3 ft (0.9 m), Limb and Chest Leads
Shielding Shielded
Cable Jacket TPU, Gray
Cable Diameter 0.10 in (2.6 mm)
Patient Size Adult/Pediatric
Lifecycle Reusable
Latex-Free Yes
Sterile No
Packaging 1 per Bag
Weight 0.3 lbs

Compatible Equipment Models

Manufacturer Compatible Models
GE Healthcare CARESCAPE B105, B125, B450, B650, B850, CARESCAPE ONE; Procare B40; ApexPro CH; Aisys CS2
GE Healthcare (Imaging) Logiq 5, Logiq 7, Logiq E9; Vivid 7, Vivid e9, Vivid i, Vivid q, Vivid S5, Vivid S6, Vivid S70N, Vivid E80, Vivid E90, Vivid E95
GE Healthcare / Marquette Dash 1000, 2000, 2500, 3000, 4000, 5000; Dash PRO 2000, 3000, 4000
GE Healthcare / Marquette Solar 3000, 8000, 9500; Eagle, Eagle Systems; Responder 2000, 3000
GE Healthcare / Marquette Tram 100, 200, 300, 400, 451, 500, 600, 800; PDM Module; MAC-Lab; Unity Systems
GE Healthcare / Corometrics 120, 250cx, 259cx
Datex-Ohmeda Aestiva/5, E-PRESTN, M-PRESTN, Unity
Draeger Narkomed 6400

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
GE Healthcare 2106389-001, 2106389-002, 2106389-005
GE Healthcare 2106391-001, 2106391-002, 2106391-005
GE Healthcare / Marquette 412681-001, 412681-002, 412681-005
Marquette 414556-001, 414556-002, 414556-005
Marquette E9002ZW, E9003CJ
AMC LW-3410029/5A, LW-3410051/5A, LW-34100MX/5A
AMC LW-3400029/5A (Individually Replaceable)
Curbell LDW-05BW-29AM-0000, LDW-05BW-51AM-0000, LDW-05BW-MXAM-0000
Pacific Medical NLMQ5251-S
RPI LKM055, LKM057 (Individually Replaceable)
Sage Services Group L02-05-29P, L02-05-51P, L02-05-MP
Tenacore 41738-P

IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE, Dash, and Solar patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the GE 2106389-001 Compatible 5-Lead ECG Leadwire?

The GE Healthcare 2106389-001 compatible 5-lead ECG leadwire is a reusable, aftermarket lead set for GE’s Multi-Link ECG system. It carries cardiac signals from five surface electrodes, four limb leads and one chest lead, to a Multi-Link trunk cable and on to the monitor. The five-lead configuration supports multi-lead arrhythmia and ST-segment monitoring in the ICU, OR, emergency department, and step-down units. It is a compatible replacement, not an original GE part, and it is built to the same fit, form, and function as the OEM 2106389-001 and 412681-001 lead sets.


Compatible Equipment Models

GE Multi-Link leadwires are among the most widely used ECG accessories in US hospitals, and this compatible set fits the full range of equipment that accepts Multi-Link trunk cables. That includes GE CARESCAPE B105, B125, B450, B650, B850, and CARESCAPE ONE monitors, the Procare B40, Dash 1000 through Dash 5000 and Dash PRO monitors, Solar 3000, 8000, and 9500 systems, Tram modules, the PDM module, ApexPro CH telemetry, Eagle and Responder monitors, MAC-Lab, and Unity Systems. It also fits the GE Aisys CS2 anesthesia system, Logiq and Vivid ultrasound systems, the Corometrics 120, 250cx, and 259cx fetal monitors, Datex-Ohmeda Aestiva/5, E-PRESTN, M-PRESTN, and Unity equipment, and the Draeger Narkomed 6400.


Design and Construction

All five leads are 3 ft (0.9 m) long and shielded, which helps keep the ECG trace clean in electrically noisy clinical settings. The trunk end has a molded GE Multi-Link connector that snaps securely into the matching Multi-Link trunk cable. The patient end has grabber/pinch clips that attach to both tab and snap-style electrodes. The leads follow the AHA color code: white for right arm, black for left arm, red for left leg, green for right leg, and brown for the chest lead. The gray TPU jacket is about 0.10 in (2.6 mm) in diameter and stays flexible and tangle-resistant through repeated cleaning. The set is latex-free, non-sterile, rated for adult and pediatric patients, weighs about 0.3 lbs, and ships one per bag.


When to Replace Your GE Multi-Link 5-Lead Leadwire

Reusable leadwires wear out from constant clip handling, flexing, and repeated disinfection. Replace the set when you see baseline wander or noise on one or more leads, intermittent “lead fail” alarms with good electrode contact, grabber clips that no longer hold the electrode firmly, cracked or stiff jacketing, exposed shielding, faded color coding, or a Multi-Link connector that no longer locks into the trunk cable. A failing chest lead can distort the V-lead view that ST analysis depends on, so many units replace lead sets at the first sign of wear and keep spares on hand.


Cross Reference and Interchange Part Numbers

This compatible 5-lead grabber leadwire, IPR Medical SKU EL-MQ5-90G-A, cross-references to GE Healthcare part numbers 2106389-001, 2106389-002, 2106389-005, 2106391-001, 2106391-002, and 2106391-005, and to GE Marquette 412681-001, 412681-002, 412681-005, 414556-001, 414556-002, 414556-005, E9002ZW, and E9003CJ. It also interchanges with AMC LW-3410029/5A, LW-3410051/5A, LW-34100MX/5A, and LW-3400029/5A; Curbell LDW-05BW-29AM-0000, LDW-05BW-51AM-0000, and LDW-05BW-MXAM-0000; Pacific Medical NLMQ5251-S; RPI LKM055 and LKM057; Sage Services Group L02-05-29P, L02-05-51P, and L02-05-MP; and Tenacore 41738-P. Some of these OEM and aftermarket numbers are the same lead set in a different lead length, so confirm the 3 ft (0.9 m) length suits your application when replacing a longer set.


Why Source ECG Leadwires from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. Our compatible leadwires, cables, and sensors give biomedical departments an affordable alternative to OEM accessories while matching OEM fit and function across large GE CARESCAPE, Dash, and Solar fleets. Our team can help confirm the right lead set for your monitors, source hard-to-find accessories, and support your equipment with in-house repair services.

IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE, Dash, and Solar patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.