  • Philips Avalon Toco+ MP Fetal Transducer (M2735A) | DECG/MECG/IUP

    $1,495.00

    The Philips Avalon Toco+ MP Transducer (M2735A) is the most versatile wired Smart Transducer in the Avalon family — it measures uterine activity via external Toco, captures maternal pulse with built-in Smart Pulse, and accepts adapter cables for direct fetal ECG (DECG), maternal ECG (MECG), or intrauterine pressure (IUP). One transducer covers four measurement modes, which is why labor and delivery floors keep the M2735A on hand even when most patients are monitored externally.

    The Toco+ MP connects to any of the four fetal sensor sockets on Avalon FM20, FM30, FM40, or FM50 monitors via a standard D-shaped connector. Smart Pulse is always active when the transducer is applied, feeding maternal pulse into the monitor’s Cross-Channel Verification (CCV) feature to reduce the risk of mistaking maternal pulse for fetal heart rate. When DECG, MECG, or IUP monitoring is needed, the user simply plugs the appropriate adapter cable into the transducer’s auxiliary connector — the monitor automatically detects the mode.

    OEM Part Number
    M2735A (989803143681)

    Measurements
    Toco, Smart Pulse, DECG, MECG, IUP

    Compatible Monitors
    Avalon FM20, FM30, FM40, FM50

    Connector
    D-shaped (plug-and-play to any fetal sensor socket)

    Auxiliary Connector
    7-pin D-type for DECG/MECG/IUP adapter cables

    Smart Pulse
    Built-in, no separate SpO2 or MECG sensor required

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Toco+ MP Transducer (M2735A). Contact us at 855-477-8866 or cs@iprmed.com.

    Also available from IPR Medical:
    Philips M2734A / M2734B Smart Toco MP Transducer — wired external Toco with Smart Pulse  | 
    Philips Avalon Ultrasound Fetal Transducer (M2736A) — wired US transducer for external FHR  | 
    Philips Avalon CL Wireless Toco+ MP (866075) — cableless equivalent  | 
    Philips Avalon CL Wireless ECG/IUP (866077) — cableless DECG/MECG/IUP  | 
    Philips Avalon FM50 Fetal Monitor — host monitor

  • Philips Avalon Ultrasound Fetal Transducer

    $1,475.00

    The Philips Avalon Ultrasound Fetal Transducer is a state-of-the-art device designed to deliver precise and continuous monitoring of fetal heart rate and activity. This advanced transducer leverages cutting-edge ultrasound technology to ensure accurate and reliable data, which is crucial for making informed clinical decisions during labor and delivery. Its ergonomic design and lightweight construction ensure patient comfort and ease of use for healthcare providers. The Philips Avalon Ultrasound Fetal Transducer integrates seamlessly with existing Philips fetal monitoring systems, providing a cohesive and efficient workflow in maternity wards. The device features a durable, high-quality build, ensuring consistent performance even in the most demanding clinical settings. Real-time, clear displays and alerts keep healthcare providers informed of any changes in fetal status, allowing for timely interventions. The transducer’s intuitive interface simplifies setup and operation, reducing training time and enhancing overall efficiency. Invest in the Philips Avalon Ultrasound Fetal Transducer for unparalleled accuracy, reliability, and comfort in fetal monitoring.

     

    Brand new units may be available. Please contact us directly for more information.

  • Philips Avalon Ultrasound Transducer

    $1,995.00

    The Avalon Ultrasound system by Philips is a top-tier solution designed for precise and reliable fetal and maternal monitoring. Featuring advanced ultrasound technology, it ensures accurate and continuous monitoring of fetal heart rate and uterine activity, providing critical insights for informed clinical decisions. Its user-friendly interface and intuitive controls make setup and operation straightforward, allowing healthcare professionals to focus on patient care. The Avalon Ultrasound system boasts seamless integration with existing hospital networks, enhancing workflow efficiency and enabling real-time data sharing. Its compact, ergonomic design ensures easy portability and adaptability to various clinical settings, from labor and delivery rooms to intensive care units. Constructed with high-quality materials, the system promises durability and consistent performance even in demanding environments. Advanced safety features and comprehensive monitoring capabilities make it an indispensable tool for ensuring the well-being of both mother and baby. Invest in the Philips Avalon Ultrasound system for unparalleled accuracy, efficiency, and reliability in fetal and maternal healthcare.

     

    Brand new units may be available. Please contact us directly for more information.

  • Philips CL Wireless ECG / IUP Transducer (866077)

    $1,195.00

    The Philips Avalon CL Wireless ECG/IUP Transducer (866077) is a cableless, battery-powered transducer that captures maternal ECG, fetal ECG (DECG), and intrauterine pressure (IUP) on a single device — giving labor and delivery teams three internal and maternal measurements without tethering the patient to the monitor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same measurement performance as wired Smart Transducers while letting mothers walk, shower, or reposition during labor with an operating range of up to 100 m (300 ft) line of sight.

    The 866077 is watertight for underwater monitoring, weighs only 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic assignment and battery recharging — no patient cables, no separate charger. IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Compatible M1355A External Toco Transducer | Series 50

    $295.00

    The Philips M1355A is the external tocodynamometer (Toco) transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) and the Series 50 IP-2 (M1353A). It uses a strain-gauge–based pressure sensor strapped over the fundus of the maternal abdomen to detect the duration, frequency, and relative intensity of uterine contractions, and it pairs with the M1356A ultrasound transducer to provide a complete external CTG trace.

    Device Type
    External tocodynamometer (Toco) transducer for non-invasive uterine activity monitoring

    Compatible Monitors
    Philips Series 50 A (M1351A Single and Twins), Series 50 IP-2 (M1353A), and earlier Philips/HP M1350 fetal monitors

    Patient Population
    Antepartum and intrapartum monitoring of uterine activity

    Connector
    Keyed round multi-pin connector to the dedicated Toco socket on the Series 50 monitor

    Mounting
    Snap-clip to M1562A reusable transducer belt; transducer knob adapter (M1356-43201) optional

    Housing Color Variants
    Brown (M1355-60001) and Blue (M1355-60011) — color matches monitor housing

    IPR Medical buys, sells, repairs, and stocks parts for the Philips M1355A external Toco transducer. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Compatible M1356A Fetal Ultrasound Transducer | Series 50

    $295.00

    This is an aftermarket-compatible wide-beam Doppler ultrasound transducer designed to function as a direct replacement for the M1356A fetal ultrasound transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) and the Series 50 IP-2 (M1353A). It is applied externally to the maternal abdomen and uses a wide-beam Doppler ultrasound element to detect fetal heart sounds, which the host monitor then processes through its auto-correlation algorithm to produce a continuous fetal heart rate (FHR) trace. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.

    Device Type
    Aftermarket-compatible external wide-beam Doppler ultrasound transducer for fetal heart rate (FHR)

    Replaces / Cross Reference
    M1356A fetal ultrasound transducer (also referenced as part 80310120)

    Compatible Monitors
    Philips Series 50 A (M1351A Single and Dual Ultrasound Twins), Series 50 IP-2 (M1353A), and earlier Philips/HP M1350 series fetal monitors

    Patient Population
    Antepartum (from approximately 20–25 weeks gestation) and intrapartum monitoring

    Connector
    Keyed round multi-pin connector compatible with the US, US1, or US2/ECG socket on the Series 50 monitor

    Mounting
    Snap-clip belt fixing onto compatible reusable fetal monitoring belts (e.g., M1562A); transducer knob adapter (M1356-43201) optional

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Series 50 fetal monitor family, including aftermarket-compatible fetal ultrasound transducers for the M1356A. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Compatible Wireless Toco Transducer for Philips Avalon | M2725A

    $1,395.00

    This is an aftermarket-compatible cordless Toco transducer designed to function as a direct replacement for the M2725A wireless Toco fetal transducer used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50) when paired with the Avalon CTS cordless transducer base station (M2720A). It uses a strain-gauge pressure sensor to detect uterine activity by evaluating the hardness of the maternal abdomen during labor, transmitting the signal wirelessly to the CTS base so the patient retains freedom of movement during antepartum testing and labor and delivery. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.

    Device Type
    Aftermarket-compatible cordless (wireless) external Toco transducer for fetal/maternal monitoring

    Replaces / Cross Reference
    M2725A cordless Toco transducer (also referenced as part 862488)

    Compatible Monitors
    Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) — used together with the Avalon CTS base station (M2720A)

    Patient Population
    Antepartum testing and labor and delivery; ambulatory patients within the CTS base station’s coverage area

    Key Features
    Cordless operation, lightweight handheld form factor, waterproof housing for shower/bath use during labor, on-board status indicators

    Mounting
    Snap-clip belt fixing onto compatible reusable or waterproof fetal monitoring belts

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips M2734A / M2734B Smart Toco MP Transducer | Avalon

    $1,395.00

    The Philips M2734A and M2734B are wired Smart Toco MP transducers used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50). They combine two parameters in a single sensor — external uterine activity (Toco) and maternal pulse (MP) — and enable the Avalon platform’s Smart Pulse automated coincidence detection, which cross-checks the maternal pulse against the fetal heart rate to confirm the host monitor is not inadvertently tracking maternal heart rate as fetal. The M2734B is the successor revision to the M2734A and is functionally interchangeable on the Avalon Toco socket; both are auto-identifying via the Smart-interface (pink) connector and carry internal calibration data storage.

    Device Type
    Wired dual-parameter Smart Toco MP transducer (uterine activity + maternal pulse)

    Models
    M2734A (original Smart Toco MP) and M2734B (successor revision); both share the same role and Avalon socket

    Compatible Monitors
    Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) at supported software revisions

    Connector
    Wired Smart-interface (pink) connector to the dedicated Toco socket on the Avalon host monitor

    Key Features
    Dual-parameter Toco + maternal pulse, Smart Pulse coincidence detection, waterproof housing for shower/bath use, latex-free, auto-identification, internal calibration data storage

    Patient Population
    Antepartum testing and labor and delivery

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon fetal monitor family, including the M2734A and M2734B Smart Toco MP transducers. Contact us at 855-477-8866 or cs@iprmed.com.

  • -22%
    RecertifiedFluid Warming SystemQuick View

    Smiths Medical HOTLINE 3 Blood and Fluid Warmer

    Original price was: $895.00.Current price is: $695.00.

    The Smiths Medical HOTLINE® 3 Blood and Fluid Warmer (Model HL-390-38) — now distributed by ICU Medical — is a proven routine-flow fluid warming system designed to deliver blood and IV fluids to patients at normothermic temperatures under gravity flow conditions. The HOTLINE 3 uses a closed recirculating solution system that surrounds the sterile IV line with a continuous layer of warmed fluid, eliminating patient line cool-down from the warmer all the way to the access site. The proprietary triple-lumen tubing design keeps the infusate path warm without exposing it to any direct heating element. The HL-390-38 sets a recirculating solution temperature of 38°C, with an electronic primary control circuit that limits recirculating solution to 38°C maximum and an independent watchdog circuit that alarms and stops the pump at 39.2°C — keeping the system inherently free of hot spots. Compatible with the HOTLINE® 3 L-370 Fluid Warming Set (single-use, sold separately), the HL-390 mounts to a standard IV pole and serves operating rooms, recovery rooms, ICUs, and emergency departments handling patients at risk of hypothermia.

    IPR Medical buys, sells, repairs, and stocks parts and administration sets for the HOTLINE® 3 Blood and Fluid Warmer. Contact us at 855-477-8866 or cs@iprmed.com.

  • -14%
    New
    Quick View

    Stryker/Gaymar T/Pump TP700

    Original price was: $1,395.00.Current price is: $1,195.00.

    The Stryker/Gaymar T/Pump® TP700 is a professional-grade localized temperature therapy system that circulates temperature-controlled water through a Stryker Mul•T•Pad® to deliver precise warming or cooling therapy to targeted body areas. Four selectable setpoints — 50°F (cooling), 95°F, 100°F, and 107°F — cover everything from post-operative hypothermia prevention and edema management to chronic joint pain and muscle strain relief. The TP700 upgrades over the classic TP600 with a fourth warming setpoint (95°F), programmable therapy cycles (20-minute, 30-minute, or continuous), and a setpoint lockout feature that prevents accidental temperature changes mid-treatment. A three-layer safety architecture — dual temperature sensors, dual microprocessors, and a mechanical over-temperature thermostat — ensures the pad never exceeds the 107°F maximum contact surface temperature. At 6.5 lbs empty and with built-in hose and cord management, the TP700 is easy to position at bedside, in recovery, or in the OR.

    IPR Medical buys, sells, and repairs the Stryker/Gaymar T/Pump TP700 and stocks compatible Mul•T•Pad® accessories and replacement parts. Contact us at 855-477-8866 or cs@iprmed.com.

  • -11%
    RecertifiedQuick View

    Baxter Flo-Gard 6200

    Original price was: $895.00.Current price is: $795.00.

    The Baxter Flo-Gard 6200 is a single-channel volumetric infusion pump built for reliable, accurate intravenous delivery of a wide range of fluids — including blood and fat emulsions — across primary and secondary infusion programs. Operating on standard 115 VAC power or its self-contained rechargeable battery, it delivers flow rates from 1 to 999 mL/hr in 1 mL/hr increments with a VTBI range of 1 to 9,999 mL. Automatic piggybacking switches seamlessly from the secondary program back to the primary when secondary infusion completes, and a built-in safety clamp prevents accidental free flow any time the pump door is opened.

    The Flo-Gard 6200 is an older pump — discontinued by Baxter — but it remains one of the most straightforward, dependable large-volume pumps in clinical use today. Hospitals, long-term care facilities, outpatient clinics, and veterinary practices continue to rely on them for good reason: they are simple to load, simple to program, and built to last.

    IPR Medical maintains a large inventory of Flo-Gard 6200 parts — including batteries, fuses, pump mechanisms, power cords, and more — to keep your fleet running strong. Whether you need a single unit serviced or a supply of components to support ongoing maintenance, we have what you need.

  • -39%
    RecertifiedBaxter Flo-Gard 6201Quick View

    Baxter Flo-Gard 6201

    Original price was: $895.00.Current price is: $550.00.

    The Baxter Flo-Gard 6201 is a single-channel linear peristaltic volumetric infusion pump designed to deliver a wide variety of fluids — including blood and fat emulsions — across a broad range of infusion rates. A significant upgrade over the 6200, the 6201 adds incremental 0.1 mL/hr flow rate precision, a Programmed Delivery Profile (PDP) with up to 10 sequential infusion steps for ramped or manual programming, selectable air-in-line detection sensitivity, selectable downstream occlusion sensitivity, a Flow Check display, volume-time programming, a five-hour infusion data memory, and suitability for epidural administration.

    It runs on 110/120V AC or an internal 12-volt sealed lead-acid battery with approximately 6 hours of runtime. Automatic piggybacking, a locking control panel, and an automatic safety clamp that occludes tubing on door open round out a pump that hospitals continue to rely on long after its discontinuation.

    The Flo-Gard 6201 is an older, discontinued pump — but its dependability has kept it in active service across healthcare settings for decades. IPR Medical maintains a large inventory of Flo-Gard 6201 parts to keep your fleet running strong, from batteries and fuses to pump mechanisms and power cords.