GE Healthcare 2017008-001 Compatible Dual-Tube NIBP Air Hose, Adult/Pediatric, 12 ft (3.6 m)
$50.00The GE Healthcare 2017008-001 compatible NIBP air hose is a reusable, aftermarket replacement (not OEM) for GE’s dual-tube adult/pediatric blood pressure hose, built to match the original’s fit, form, and function.
Hose Type
Dual-TubeMonitor-End Connector
GE Adult Black BlockCuff-End Connectors
Dual Twist-Lock (for Female Cuff Fittings)Hose Length
12 ft (3.6 m)Patient Size
Adult/PediatricConstruction
PVC, Reusable, Latex-FreeWorks with: GE Dash 2000–5000, CARESCAPE B450/B650/B850, Solar, Tram, Corometrics 120/250/259 series, Datex-Ohmeda Aespire 7900, and more. See the Specifications tab for the full list. Browse more NIBP hoses and accessories.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 2017009-001 Compatible Neonatal Dual-Tube NIBP Air Hose, Luer Slip, 8.2 ft (2.5 m)
$60.00The GE Healthcare 2017009-001 compatible neonatal NIBP air hose (SKU BPH-ND25-14N-17) is a reusable, aftermarket replacement (not OEM) for GE’s dual-tube neonatal blood pressure hose, built to match the original’s fit, form, and function.
Hose Type
Dual-Tube, NeonatalMonitor-End Connector
GE Neonatal Black BlockCuff-End Connectors
Dual Female Safe-Release Luer (for Male Luer Slip Cuffs)Hose Length
8.2 ft (2.5 m)Patient Size
NeonateConstruction
PVC, Reusable, Latex-FreeWorks with: GE Dash 2000–5000, Eagle, Solar, Tram, CARESCAPE B105/B125/B450/B650/B850, Procare B40, Corometrics 120/250/259 series, Datex-Ohmeda Aespire 7900 and B30, and more. See the Specifications tab for the full list. Browse more NIBP hoses and accessories.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 2021197-001 Compatible IBP Adapter Cable for Edwards Transducers, 11-Pin, 13 ft (4.0 m)
$62.50The GE Healthcare 2021197-001 compatible IBP adapter cable (SKU IBP-MQ-EW40) is a reusable, aftermarket replacement (not OEM) that connects Edwards disposable pressure transducers to GE monitors with the flat 11-pin IBP input, built to match the original’s fit, form, and function.
Cable Type
IBP Adapter / Interface CableTransducer Compatibility
Edwards Disposable Pressure TransducersMonitor-End Connector
Flat 11-Pin, Dual-Keyed GETransducer-End Connector
EdwardsCable Length
13 ft (4.0 m)Construction
Gray, Reusable, Latex-FreeWorks with: GE Dash 1000–5000, Solar 7000/8000/9000, Eagle, Tram and Tram-Rac modules, PDM and CARESCAPE PDM, Procare B40, Cath-Lab and MAC-Lab, Datex-Ohmeda E-PRESTN, and Draeger Narkomed 6400. See the Specifications tab for the full list. Browse more IBP cables and accessories.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 2021406-001 Compatible SpO2 Adapter Cable for Nellcor OxiMax Sensors, 9.8 ft (3.0 m)
$60.00The GE Healthcare 2021406-001 compatible SpO2 adapter cable is a reusable, aftermarket replacement (not OEM) for GE’s Nellcor OxiMax SpO2 extension cable, built to match the original’s fit, form, and function.
SpO2 Technology
Nellcor OxiMaxCable Length
9.8 ft (3.0 m)Lifecycle
ReusableWorks with: OxiMax-equipped GE CARESCAPE B450/B650/B850/V100, Dinamap B105/B125/B155M, Procare B40, Dash 2000–5000, Solar 8000/8000M and i/9500, Tram modules, and Corometrics 128/250/259 monitors. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 2021701-001 Compatible Temperature Adapter Cable, 400 Series, Reusable, 9.8 ft (3.0 m)
$62.50The GE temperature adapter 2021701-001 compatible replacement is a reusable, aftermarket interconnect cable (not OEM) that connects a 400-series temperature probe to GE Marquette monitors and modules, built to OEM fit, form, and function.
Probe Compatibility
400 SeriesCable Length
9.8 ft (3.0 m)Lifecycle
ReusableWorks with: Marquette Dash and Eagle monitors, Tram 451 and PDM modules, GE Procare B40, and CARESCAPE B650. See the Specifications tab for the full list. Browse more temperature cables and probes.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 2027263-002 Compatible SpO2 Adapter Cable for Masimo LNCS Sensors, 7.9 ft (2.4 m)
$60.00The GE Healthcare 2027263-002 compatible SpO2 adapter cable is a reusable, aftermarket replacement (not OEM) for GE’s Masimo LNCS extension cable (Masimo LNC-10-GE), built to match the original’s fit, form, and function.
SpO2 Technology
Masimo LNCSCable Length
7.9 ft (2.4 m)Lifecycle
ReusableWorks with: Masimo-equipped GE CARESCAPE B450/B650/B850 and V100, Dinamap ProCare and B-series, Dash 2000–5000, Solar 7000/8000/i9500, Tram modules, Corometrics 250 series, and Datascope Accutorr, DPM, and Passport monitors. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 2104727-001 Compatible 10-Lead Diagnostic One-Piece EKG Cable, 4 mm Banana, Defib-Proof, AHA
$120.00The GE Healthcare 2104727-001 compatible one-piece EKG cable is a reusable, aftermarket replacement (not OEM) for GE’s 10-lead diagnostic ECG cable, with the trunk and leadwires built into a single assembly for resting 12-lead ECG.
Leads
10 (RA, LA, LL, RL, V1–V6)Design
One-Piece (Integrated Trunk and Leads)Electrode End
4 mm BananaTrunk / Lead Length
7.2 ft (2.2 m) Trunk; 2.6 ft (0.8 m) and 3.9 ft (1.2 m) LeadsProtection
Defib-Proof (with Resistors)Color Code
AHA (US)Works with: GE Marquette MAC 400, 500, 600, 800, 1000, 1100, 1200, 1600, 2000, and 3500 electrocardiographs and the Microsmart M. Browse more ECG/EKG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for GE diagnostic ECG equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 2106389-001 / 412681-001 Compatible 5-Lead Multi-Link ECG Leadwire, Grabber/Pinch, Molded, 3 ft (0.9 m), AHA
$50.00The GE Healthcare 2106389-001 compatible 5-lead ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s Multi-Link 5-lead grabber set (also sold as 412681-001), built to match the original’s fit, form, and function.
Leads
5 (RA, LA, LL, RL, V)Trunk-End Connector
GE Multi-Link, MoldedPatient-End Connector
Grabber/Pinch ClipsLead Length
3 ft (0.9 m)Color Code
AHA (US)Patient Size
Adult/PediatricConstruction
Shielded, Reusable, Latex-FreeWorks with: GE CARESCAPE B450, B650, and B850; Dash 3000, 4000, and 5000; Solar 8000 and 9500; Tram modules; ApexPro CH; Datex-Ohmeda Aestiva/5 and Unity; and more. See the Specifications tab for the full list. Browse more ECG/EKG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 2106395-001 / 421930-001 Compatible 6-Lead Multi-Link ECG Leadwire, Snap, Individual, 3 ft (0.9 m), AHA
$60.00The GE Healthcare 2106395-001 compatible 6-lead ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s Multi-Link 6-lead snap set (also referenced as 421930-001), built to match the original’s fit, form, and function.
Leads
6 (4 Limb + 2 Chest)Trunk-End Connector
GE Multi-Link, Individual LeadsPatient-End Connector
SnapLead Length
3 ft (0.9 m)Color Code
AHA (US)Patient Size
Adult/PediatricConstruction
Shielded, Reusable, Latex-FreeWorks with: GE CARESCAPE B450, B650, B850, and CARESCAPE ONE monitors, and ApexPro CH telemetry. Browse more ECG/EKG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 2106397-001 / 421932-001 Compatible 6-Lead Multi-Link ECG Leadwire, Grabber/Pinch, Individual, 3 ft (0.9 m), AHA
$60.00The GE Healthcare 2106397-001 compatible 6-lead ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s Multi-Link 6-lead grabber set (also sold as 421932-001), built to match the original’s fit, form, and function.
Leads
6 (4 Limb + 2 Chest)Trunk-End Connector
GE Multi-Link, Individual LeadsPatient-End Connector
Grabber/Pinch ClipsLead Length
3 ft (0.9 m)Color Code
AHA (US)Patient Size
Adult/PediatricConstruction
Shielded, Reusable, Latex-FreeWorks with: GE CARESCAPE B450, B650, B850, and CARESCAPE ONE monitors, and ApexPro CH telemetry. Browse more ECG/EKG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 22341809 / 2104723-001 Compatible 10-Lead Diagnostic EKG Trunk Cable, Defib-Proof, 8.2 ft (2.5 m), AHA
$120.00The GE Healthcare 22341809 / 2104723-001 compatible 10-lead EKG trunk cable (SKU EKT10R-MQ-GE-A) is a reusable, aftermarket replacement (not OEM) for the diagnostic 12-lead trunk cable used on GE MAC resting electrocardiographs, built to match the original’s fit, form, and function.
Cable Type
10-Lead Diagnostic EKG Trunk CableLead Placement
Limb + Chest (RA, LA, LL, RL, V1–V6), AHAMonitor-End Connector
DB-15Leadwire-End Connector
Twin-Pin Yoke for GE Multi-Link LeadwiresDefibrillation Protection
Defib-Proof, 10K OhmCable Length
8.2 ft (2.5 m)Works with: GE Marquette MAC 400, 500, 600, 800, 1000, 1100, 1200, 1600, 2000, and 3500 electrocardiographs and the Microsmart M. See the Specifications tab for the full list. Browse more ECG/EKG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
GE Healthcare 394111-005 / 394111-502 Compatible 5-Lead ApexPro FH Telemetry ECG Leadwire, Grabber/Pinch, Molded, 3 ft (0.9 m), AHA
$70.00The GE Healthcare 394111-005 compatible 5-lead telemetry ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s ApexPro FH telemetry lead set (also referenced as 394111-502), built to match the original’s fit, form, and function.
Leads
5 (RA, LA, LL, RL, V)Transmitter-End Connector
Molded ApexPro FH (DIN-Style)Patient-End Connector
Grabber/Pinch ClipsLead Length
3 ft (0.9 m)Color Code
AHA (US)Patient Size
Adult/PediatricConstruction
Shielded, Reusable, Latex-FreeWorks with: GE ApexPro FH telemetry transmitters and Mindray/Datascope DT-4500 telemetry. Browse more ECG/EKG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring and telemetry equipment. Call 855-477-8866 or email cs@iprmed.com.