3M Bair Hugger Model 775 Warming Unit | Forced-Air

$1,895.00 Original price was: $1,895.00.$1,695.00Current price is: $1,695.00.

The 3M Bair Hugger Model 775 is a forced-air warming unit used across pre-operative, intra-operative, and post-anesthesia care settings to prevent and treat perioperative hypothermia. The unit delivers temperature-controlled warm air through a sensor-equipped hose into any Bair Hugger blanket or warming gown, supporting pediatric through adult patients. The 775 is compact, rolling-cart or rail mountable, and tracks therapy duration, fault codes, and cumulative use through its front panel — making it a workhorse in OR, PACU, and pre-op fleets.

Device Type Forced-air patient warming unit
Temperature Settings High 109.4°F, Medium 100.4°F, Low 89.6°F, Ambient
Patient Population Pediatric and adult
Airflow / Sensing Two airflow settings; hose-end temperature sensing
Filter MERV 14
Mounting Hard surface, rolling cart, bed rail, or IV pole

IPR Medical buys, sells, repairs, and stocks parts for the 3M Bair Hugger Model 775 Warming Unit. Contact us at 855-477-8866 or cs@iprmed.com.

SKU: 3m-bair-hugger-model-775-warming-unit Category: Brand:
Send In 3M Bair Hugger Model 775 Warming Unit | Forced-Air for Repair

3M Bair Hugger Model 775 — Specifications


Manufacturer 3M
Model Bair Hugger Model 775 (Catalog No. 77500)
Device Classification Forced-air temperature management (warming) unit for perioperative use
Intended Use Prevention and treatment of hypothermia; patient thermal comfort across pediatric and adult populations in all clinical settings
Patient Population Pediatric and adult
User Interface Front-panel membrane keys and digital display; alternative mode access for service functions
Temperature Settings High: 109.4°F ± 2.7°F; Medium: 100.4°F ± 2.7°F; Low: 89.6°F ± 2.7°F; Ambient: room temperature
Temperature Sensing Three temperature sensors; hose-end temperature sensing for delivery-point accuracy
Airflow Two airflow settings, adjustable from the front panel
Alarms Audible and visual over-temperature alarm; high-temperature limit ≤127.4°F ±3°C
Air Filter MERV 14 (refer to OEM Operator’s Manual for filtration FAQ)
Hose Replaceable hose with integrated sensor assembly
Device Tracking Built-in hour meter; tracks therapy duration, cumulative use, over-temperature events, and fault codes; viewable from front panel
Power 110–120 VAC, 50/60 Hz, 11.7 A
Battery Not battery-powered; AC mains operation only
Mounting Options Hard surface, OEM rolling cart (90090), bed rail mount, or accessory mount (90096)
Dimensions 13″ H × 14″ W × 13″ D
Weight 16 lb
Disposable Compatibility All 3M Bair Hugger Warming Blankets and Warming Gowns (pediatric through adult); 3M Bair Hugger 241 Blood/Fluid Warming Set
Regulatory FDA 510(k) K053645 (Arizant Healthcare, Inc., cleared 2006-03-09); Product Code DWJ; Cardiovascular advisory panel
FDA Device Corrections Historical Class 2 power cord recall (Z-0895-2010, December 2009), Terminated April 2012. See the Description Tab for full detail.

IPR Medical buys, sells, repairs, and stocks parts for the 3M Bair Hugger Model 775 Warming Unit. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: 3M, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by 3M.

Overview

The 3M Bair Hugger Model 775 Warming Unit is a forced-air temperature management device used to prevent and treat perioperative hypothermia and to provide thermal comfort across pre-operative, intra-operative, and post-anesthesia care settings. The unit draws filtered room air, heats it to one of three patient-warming setpoints (plus an ambient option), and delivers it through a sensor-tipped hose into a compatible Bair Hugger warming blanket, warming gown, or the Bair Hugger 241 Blood/Fluid Warming Set. The 775 supersedes earlier Bair Hugger units (including the 505 and 750) and remains one of the most widely deployed forced-air warming platforms in U.S. hospitals. It is intended for both pediatric and adult patients and is cleared by the FDA under 510(k) K053645 to Arizant Healthcare, Inc., the original manufacturer prior to acquisition by 3M and the subsequent transition of the Bair Hugger product line to Solventum.


Display and User Interface

The Model 775 uses a front-panel membrane keypad and digital display rather than a touchscreen. Clinicians select one of four temperature setpoints (High, Medium, Low, or Ambient) and one of two airflow settings directly from the front panel, and the digital display indicates the active setpoint and any fault or alarm condition. Hose-end temperature sensing means the displayed and regulated value reflects air temperature at the delivery point — closer to the patient than at the heater outlet — which helps the unit respond quickly when patient demand or hose routing changes. Service and calibration functions are accessed through alternative-mode key combinations described in the OEM service manual; this allows biomed staff to read fault history, cumulative hours, and calibration data without opening the chassis. The interface is intentionally simple, which reduces training time across rotating PACU and OR staff and shortens setup at the start of each case.


Forced-Air Warming Performance and Blanket Compatibility

The 775 delivers warm air at three regulated setpoints — High 109.4°F, Medium 100.4°F, and Low 89.6°F — each held within ±2.7°F, plus an Ambient setting that circulates room-temperature air for thermal comfort without active heating. Three internal temperature sensors plus hose-end sensing provide redundancy for both regulation and over-temperature protection; the audible and visual high-temperature alarm trips at or below 127.4°F (±3°C). Two airflow settings allow clinicians to balance heat delivery against patient comfort and against the surgical field — higher airflow for rapid rewarming, lower airflow for steady-state maintenance and for cases where airflow disturbance is a concern. The hose terminates in a connector compatible with the full Bair Hugger blanket portfolio, including full-body, upper-body, lower-body, underbody, pediatric, and surgical-access blankets, as well as the Flex, Plus, and OR warming gowns. This broad compatibility lets a single 775 unit serve multiple service lines from pre-op staging through PACU recovery.


Filtration and Infection Prevention Considerations

The Model 775 uses an OEM MERV 14 air filter (catalog 90047) on the air intake, the same filter rating used in many hospital HVAC final-filtration stages. Forced-air warming filtration has been the subject of clinical debate over the past decade, and the OEM Operator’s Manual includes a dedicated frequently-asked-questions section addressing filter performance and recommended replacement intervals. Filter replacement is a field-serviceable task that does not require chassis disassembly; cumulative hours of use are reported on the front panel through alternative-mode access, which helps biomed teams plan filter changes based on actual run time rather than calendar interval alone. Facilities running 775 fleets in high-utilization ORs should align filter replacement with the OEM-recommended schedule and document filter changes in the equipment record. The Bair Hugger 241 Blood/Fluid Warming Set is an additional disposable compatible with the 775 for intraoperative warming of crystalloid or blood product through the same forced-air pathway.


Portability, Mounting, and Power

The Model 775 weighs 16 lb and measures 13 inches in each principal dimension, giving it a footprint small enough for a counter, rolling cart, or rail mount. The OEM rolling cart (catalog 90090), optional rolling-cart handle (90094), and accessory mount (90096) are the standard mobility configurations; the unit can also be secured to a bed rail through OEM mounts. The device operates on 110–120 VAC at 50/60 Hz and draws up to 11.7 A under full heating load, which is the principal reason the 775 should be plugged into a hospital-grade circuit rather than shared with high-draw equipment on the same outlet. There is no internal battery — therapy is interrupted if mains power is lost, so patient transport with active warming requires a uninterrupted power path or a brief therapy pause. The replacement power cord (Bair Hugger Power Cord 120V-B, catalog 90224) is OEM-specified and is the same cord covered by the historical 2009 power cord recall described in the FDA section below.


Device Tracking, Fault Codes, and Service Diagnostics

The Model 775 tracks therapy duration per session and cumulative hours through a built-in hour meter, and it logs over-temperature events and fault codes that are retrievable through alternative-mode access from the front panel — no chassis access is required to read service history. This makes the 775 friendly to clinical-engineering workflows: a biomed can perform an incoming inspection or annual PM and pull cumulative use and fault history within seconds. Calibration is verified against the OEM Temperature Test Unit (catalog 22110) or the Bair Hugger Calibration Test Kit (90055), both of which interface with the hose-end sensor circuitry. The service manual documents adjustment procedures, harness diagrams, and component-level troubleshooting for the heater assembly, blower motor, sensor harness, and power supply. Common service items include filter replacement, hose-with-sensor assembly replacement (catalog 90046), and periodic verification of the over-temperature shutdown threshold.


Service and Maintenance Considerations

The Bair Hugger 775 is not a network-connected device and does not integrate with hospital EMR systems — there is no Ethernet, no Wi-Fi, and no patient-data export. This simplifies the cybersecurity posture for the device but means that perioperative documentation of warming therapy must be captured separately in the anesthesia or PACU record. Standard preventive maintenance includes annual electrical safety testing per IEC 60601-1, periodic filter replacement, hose-with-sensor inspection, calibration verification with an OEM test unit, and visual inspection of the chassis and power cord. Because the device draws nearly 12 amps at full load, IPR Medical recommends including a load test as part of incoming inspection, particularly on units that have been in storage or that arrive from a fleet refresh. Replacement parts most commonly requested through IPR include the replacement hose with sensor assembly, replacement filter, sheet clip, rolling cart, and OEM power cord.


FDA Device Corrections and Safety Bulletins

The 3M Bair Hugger Model 775 was subject to one FDA-documented Class 2 device correction involving its OEM AC power cord. In December 2009, Arizant Healthcare, Inc. initiated a nationwide voluntary recall (FDA recall number Z-0895-2010, openFDA cfres_id 88575) of 100/110-volt power cords supplied with multiple Bair Hugger and Bair Paws temperature management units, including the Model 775, Model 750, Model 505, Model 500/OR, and Bair Paws Models 850 and 875. The recall covered Arizant part number 502221, Model 90024 — the original-issue power cord manufactured by Electri-Cord Manufacturing Corporation. The root cause was identified as nonconforming material or component on the power cord assembly. Arizant distributed an Urgent Medical Device Power Cord Recall letter dated December 17, 2009 to biomed and recall coordinators, and a replacement power cord program was set up through arizant.com/powercords. The recall was assigned FDA Class 2 status, and the recall event was formally terminated by the FDA on April 19, 2012. Units in current circulation should already carry the replacement OEM cord; the current OEM-specified replacement power cord for the Model 775 is the Bair Hugger Power Cord 120V-B, catalog number 90224.

Recommended actions: Confirm any Model 775 unit entering or already in service is fitted with the current OEM-specified power cord (Bair Hugger Power Cord 120V-B, catalog 90224) and not a 2009-vintage Arizant 502221/Model 90024 cord. Inspect cords for damage at the strain reliefs and plug body during every preventive-maintenance interval, and replace any cord showing wear or heat discoloration regardless of model year. Document the cord part number in the equipment record so future inspections can verify the unit remained in compliance after the 2012 recall termination.

Because FDA device corrections and safety communications may be updated or expanded after the date of this listing, IPR Medical recommends that facilities also check the FDA’s official resources directly to ensure they have the most current information.

FDA resources for further review:
FDA Medical Device Recalls Database  |
FDA Medical Device Safety


IPR Medical — Buy, Sell, Repair, and Parts

IPR Medical buys, sells, repairs, and stocks parts for the 3M Bair Hugger Model 775 Warming Unit. We support hospital biomed and clinical engineering departments, ASCs, GPO buyers, and equipment dealers with refurbished 775 units, repair turn-arounds, individual replacement parts (hose-with-sensor assemblies, filters, sheet clips, power cords, rolling carts), and fleet trade-in or fleet-refresh purchasing. Because the 775 family was originally manufactured by Arizant Healthcare, transferred to 3M, and is now part of the Solventum Bair Hugger portfolio, IPR Medical can also help facilities sort out OEM versus aftermarket parts compatibility across the model’s service life. Reach out for current availability, pricing, calibration documentation, or to discuss surplus units from a fleet retirement.

IPR Medical buys, sells, repairs, and stocks parts for the 3M Bair Hugger Model 775 Warming Unit. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: 3M, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by 3M.

Weight 20 lbs
Dimensions 7 × 17 × 15 in
Product Condition

,

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the 3M Bair Hugger Model 775 Warming Unit. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.


Unit, Replacement Hose, and Filter

Bair Hugger Warming Unit, Model 775 (77500) Complete forced-air warming unit, OEM catalog number for the full Model 775 unit.
Replacement Hose with Sensor Assembly (90046) OEM replacement delivery hose with integrated hose-end temperature sensor, specific to the 775 platform.
Replacement Filter (90047) OEM MERV 14 air-intake filter for the 700-series Bair Hugger warming units.
Power Cord 120V-B (90224) Current OEM-specified replacement power cord; supersedes the recalled 2009-era 502221 / Model 90024 cord.

Mounting and Transport Accessories

Rolling Cart (90090) OEM rolling cart designed specifically for the Model 775; sold separately from the warming unit.
Rolling Cart Handle (90094) OEM accessory handle for the 90090 rolling cart.
Mount (90096) OEM mount accessory for the Model 775; supports bed-rail and IV-pole installations.
Sheet Clip (90063) Tethered sheet clip used to secure the warming hose and blanket interface during therapy. Compatible with Model 675 and Model 775.

Calibration and Service Tools

Temperature Test Unit (22110) OEM test unit used for verifying hose-end temperature accuracy on the Model 675 and Model 775.
Calibration Test Kit (90055) OEM calibration kit listed in the Bair Hugger spare parts catalog. Contact IPR Medical to confirm the specific configuration compatible with your 775 software revision.

Compatible Warming Blankets

Full Body Warming Blanket (30000) 84″ × 36″ full-body blanket; integrated tuck flaps and foot drape.
Multi-Access Warming Blanket (31500) 84″ × 36″ full-body blanket with six access panels for chest, arms, torso, and lower body.
Surgical Access Warming Blanket (57000) 84″ × 36″ with two resealable hose ports and a large surgical access window; suitable for spinal, abdominal, hip, and pelvic procedures.
Lower Body Warming Blanket (52500) 60″ × 36″ lower-body blanket for supine, lateral, or prone upper-body surgeries.
Small Lower Body Warming Blanket (53700) 35″ × 24″ lower-body blanket sized for large pediatric or small adult patients.
Dual Port Torso Warming Blanket (54200) 42″ × 36″ upper-body blanket with two hose ports and pre-attached clear head drape.
Multi-position Upper Body Warming Blanket (62200) 78″ × 24″ upper-body blanket adaptable to multiple surgical positions.
Sterile Cardiac Warming Blanket (63000) 60″ × 36″ cummerbund-design blanket with 36″ sterile hose for cardiac procedures.

Compatible Underbody Warming Blankets

Adult Underbody Warming Blanket (54500) 74″ × 36″ radiolucent underbody blanket for cath lab and radiology suites; positioned on the table prior to patient arrival.
Spinal Underbody Warming Blanket (57501) 74″ × 36″ blanket compatible with open spinal frames; includes removable head section.
Lithotomy Underbody Warming Blanket (58501) 74″ × 36″ blanket with peritoneal cut-out and integrated tie strips for stirrups; for lower-extremity, abdominal, and pelvic procedures.
Full Access Underbody Warming Blanket (63500) 84″ × 36″ blanket with two resealable hose ports; supports supine, lateral, or prone positioning.
Large Pediatric Underbody Warming Blanket (55000) 60″ × 32″ underbody blanket for a large child or small adult; includes two clear head drapes.
Pediatric Underbody Warming Blanket (55501) 36″ × 33″ pediatric underbody blanket with uniform perforations and two resealable hose ports.

Compatible Warming Gowns

Flex Warming Gown (81103 / 81003 / 81203) Small / Standard / X-Large; warming before, during, and after surgery in a single patient gown with separate upper- and lower-body inserts and two hose ports.
Plus Warming Gown (81102 / 81002 / 81202) Small / Standard / X-Large; perioperative warming gown with two hose ports for use with the Model 775 inside and outside the OR.
OR Warming Gown (81101 / 81001 / 81201 / 81501) Small / Standard / X-Large / Pediatric; single hose port; warming before, during, and after surgery.

Blood and Fluid Warming Compatibility

Bair Hugger 241 Blood/Fluid Warming Set Disposable blood/fluid warming set compatible with the Model 775 hose for intraoperative warming of IV fluids and blood products. Contact IPR Medical for the current OEM catalog number for your fleet configuration.

IPR Medical buys, sells, repairs, and stocks parts for the 3M Bair Hugger Model 775 Warming Unit. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Reviews

There are no reviews yet.