Mindray 0012-00-1262-01 Compatible 5-Lead ECG Leadwire Set, AHA, Grabber/Pinch, Shielded, 3 ft (0.9 m)
$50.00The Mindray 0012-00-1262-01 compatible 5-lead ECG leadwire set (SKU EL-MR5-90G-A) is a reusable, aftermarket replacement (not OEM). It has shielded limb and chest leads, grabber (pinch) ends, and AHA color coding, and it connects to a Mindray or Datascope 3/5-lead ECG trunk cable.
Lead Count
5-Lead (Limb and Chest Leads)Standard
AHA (RA White, LA Black, RL Green, LL Red, V Brown)Electrode Ends
Grabber / PinchLead Length
3 ft (0.9 m), ShieldedLifecycle
Reusable, Latex-FreeReplaces
Mindray / Datascope 0012-00-1262-01, 0012-00-1262-02, 0012-00-1262-03, 0010-30-42727, and moreWorks with: Mindray and Datascope Passport, Spectrum, Trio, BeneView, BeneVision, BeneHeart, DPM, iMEC, cPM, ePM, PM-series, Expert, and MPM monitors, plus Edan X12 and iM-series and Midmark Cardell Touch (see the Specifications tab for the full list). Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray 0012-00-1261-01 Compatible 5-Lead ECG Leadwire Set, AHA, Snap, Shielded, 3 ft (0.9 m)
$50.00The Mindray 0012-00-1261-01 compatible 5-lead ECG leadwire set (SKU EL-MR5-90S-A) is a reusable, aftermarket replacement (not OEM). It has shielded limb and chest leads, snap ends, and AHA color coding, and it connects to a Mindray or Datascope 3/5-lead ECG trunk cable.
Lead Count
5-Lead (Limb and Chest Leads)Standard
AHA (RA White, LA Black, RL Green, LL Red, V Brown)Electrode Ends
SnapLead Length
3 ft (0.9 m), ShieldedLifecycle
ReusableReplaces
Mindray / Datascope 0012-00-1261-01, 0012-00-1261-02, 0012-00-1261-03, 0010-30-42735, and moreWorks with: Mindray and Datascope Passport, Spectrum, Trio, BeneView, BeneVision, BeneHeart, DPM, iMEC, cPM, ePM, and PM-series monitors, plus Edan iM-series and Midmark Cardell Touch (see the Specifications tab for the full list). Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray 0010-30-42898 Compatible 3-Lead ECG Leadwire Set, AHA, Grabber/Pinch, Shielded, 3 ft (0.9 m)
$40.00The Mindray 0010-30-42898 compatible 3-lead ECG leadwire set (SKU EL-MR3-90G-A) is a reusable aftermarket replacement (not OEM). It has shielded limb leads with grabber/pinch ends and AHA color coding, and it connects to a 3-lead ECG trunk cable.
Lead Count
3-Lead (Limb Leads)Standard
AHA (RA White, LA Black, LL Red)Electrode Ends
Grabber / PinchLead Length
3 ft (0.9 m), ShieldedLifecycle
ReusableReplaces
Mindray 0010-30-42898, 0010-30-43248, Draeger 2606497, Unimed MRB3-90PWorks with: Mindray and Datascope PM-9000, iMEC, DPM, and cPM monitors, plus 3-lead trunk cables used on Spacelabs, Nihon Kohden, Welch Allyn, Zoll, Physio-Control, and many other monitors. See the Specifications tab for the full list. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray 0010-30-42900 Compatible 3-Lead ECG Leadwire Set, AHA, Snap, Shielded, 3 ft (0.9 m)
$40.00The Mindray 0010-30-42900 compatible 3-lead ECG leadwire set (SKU EL-MR3-90S-A) is a reusable, aftermarket replacement (not OEM). It has shielded limb leads, snap ends, and AHA color coding, and it connects to a 3-lead ECG trunk cable.
Lead Count
3-Lead (Limb Leads)Standard
AHA (RA White, LA Black, LL Red)Electrode Ends
SnapLead Length
3 ft (0.9 m), ShieldedLifecycle
ReusableReplaces
Mindray 0010-30-42900, 0010-30-43249, Unimed MRB3-90SWorks with: Mindray and Datascope PM-9000, iMEC, DPM, and cPM monitors. It also works with 3-lead trunk cables on Spacelabs, Nihon Kohden, Welch Allyn, Zoll, Physio-Control, and many other monitors (see the Specifications tab for the full list). Need grabber ends for tab electrodes? See our compatible Mindray 0010-30-42898 grabber leadwire set, or browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray 115-020768-00 Compatible SpO2 Adapter Cable for Masimo LNCS Sensors, 7.9 ft (2.4 m)
$60.00The Mindray 115-020768-00 compatible SpO2 adapter cable is a reusable, aftermarket replacement (not OEM) for the Mindray/Datascope Masimo SpO2 extension cable, built to match the original’s fit, form, and function. It connects Masimo LNCS pulse oximetry sensors to Mindray and Datascope monitors equipped with Masimo SpO2.
SpO2 Technology
Masimo LNCSMonitor-End Connector
Male 8-Pin Round, KeyedSensor-End Connector
Female 9-Pin D-Sub (LNCS)Cable Length
7.9 ft (2.4 m)Construction
Reusable, Latex-FreeWorks with: Masimo-equipped Mindray BeneVision N-Series, BeneView T-Series, Passport 8/12/12m/17m, iPM and iMEC Series, ePM Series, BeneHeart D-Series, Accutorr 3 and 7, and Datascope DPM, MPM, and PM 6800 monitors. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for Mindray and Datascope patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray 0010-20-42712 Compatible SpO2 Adapter Cable for Nellcor OxiMax Sensors, 9.8 ft
$60.00The Mindray 0010-20-42712 compatible SpO2 adapter cable (SKU SA-053X-30) is a reusable, aftermarket replacement (not OEM). It connects Nellcor OxiMax-compatible SpO2 sensors to the compatible Mindray and Datascope monitors listed below.
Cable Type
SpO2 Adapter (Extension) Cable, ReusableSpO2 Technology
Nellcor OxiMax CompatibleCable Length
9.8 ft (3.0 m)Replaces
Mindray 0010-20-42712Works with: Mindray BeneView T1, T5, and T8, BeneHeart D6, select BeneVision N, ePM, and VS models, Passport 8, 12, 12m, and 17m, and select iMEC, uMEC, iPM, and cPM models, plus Datascope Accutorr 3 and 7, DPM4 through DPM7, MEC 12, MPM, and PM 6800. See the Specifications tab for the full list, including models that require the Nellcor OxiMax option. Browse more SpO2 sensors and adapter cables.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray 0010-20-42710 Compatible SpO2 Adapter Cable for Nellcor OxiSmart Sensors, 7-Pin, 7.9 ft
$60.00The Mindray 0010-20-42710 compatible SpO2 adapter cable (SKU SA-053-24) is a reusable, aftermarket replacement (not OEM). It connects Nellcor OxiSmart-compatible SpO2 sensors to the compatible Mindray, Datascope, and other monitors listed below.
Cable Type
SpO2 Adapter (Extension) Cable, ReusableSpO2 Technology
Nellcor OxiSmart CompatibleMonitor Connector
7-PinCable Length
7.9 ft (2.4 m)Replaces
Mindray 0010-20-42710, 0010-30-43112Works with: Mindray BeneView T1, T5, and T8, BeneHeart D3 and D6, select BeneVision N, ePM, and VS models, select iMEC models, iPM 9800, and Passport 8 and 12, plus Datascope Accutorr 3 and 7, DPM6, DPM7, MEC 12, MPM, PM 6800, T8, and VS 900. See the Specifications tab for the full list, including models that require the Nellcor SpO2 option. Browse more SpO2 sensors and adapter cables.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray 512FLH Compatible Adult Finger Clip SpO2 Sensor, Nellcor OxiSmart Compatible, Hard Shell, 9.8 ft
$80.00The Mindray 512FLH compatible adult SpO2 sensor (SKU SS-053-AF30) is a reusable, aftermarket replacement (not OEM). It is a hard-shell finger clip sensor for Nellcor OxiSmart-equipped monitors, including the models listed below.
Sensor Type
Hard-Shell Finger Clip, ReusablePatient Size
AdultSpO2 Technology
Nellcor OxiSmart CompatibleCable Length
9.8 ft (3.0 m)Replaces
Mindray 512FLH, 115-012807-00Works with: Mindray BeneView T1, T5, and T8, BeneHeart D3 and D6, select BeneVision N, ePM, and VS models, iPM 8, iPM 9800, uMEC 10/12/15, and Passport 8 and 12, plus Datascope Accutorr 3 and 7, DPM6, DPM7, MEC 12, MPM, PM 6800, T8, and VS 900. See the Specifications tab for the full list, including models that require the Nellcor SpO2 option. Browse more SpO2 sensors and adapter cables.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray 0010-30-42625 Compatible SpO2 Adapter Cable for Masimo LNCS Sensors, 6-Pin, 7.9 ft
$50.00The Mindray 0010-30-42625 compatible SpO2 adapter cable (SKU SA-052M-24LS) is a reusable, aftermarket replacement (not OEM). It connects Masimo LNCS-compatible SpO2 sensors to the compatible Mindray and Datascope monitors listed below.
Cable Type
SpO2 Adapter (Extension) Cable, ReusableSpO2 Technology
Masimo LNCS CompatibleMonitor Connector
6-PinCable Length
7.9 ft (2.4 m)Replaces
Mindray 0010-30-42625, 115-023136-00Works with: Datascope DPM3, DPM4, DPM5, M1K0, M2K0 (before January 2006), PM 6201, PM 8000 Express, PM 9000 Express, PM 9100, PM 9200P, and VS 800, plus Mindray PM 6000, PM 7000, PM 8000, and PM 9000 monitors. See the Specifications tab for the full list, including models that require the Masimo SpO2 option. Browse more SpO2 sensors and adapter cables.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray Compatible Adult Finger Clip SpO2 Sensor, Masimo SET Compatible, Hard Shell, 9.8 ft
$80.00This Mindray-compatible adult finger clip SpO2 sensor (SKU SS-052M-AF30) is a reusable, aftermarket replacement (not OEM). It is a hard-shell finger clip sensor for the compatible Mindray and Datascope monitors with Masimo SET SpO2 technology listed below.
Sensor Type
Hard-Shell Finger Clip, ReusablePatient Size
AdultSpO2 Technology
Masimo SET CompatibleCable Length
9.8 ft (3.0 m)Works with: Datascope DPM3, DPM4, DPM5, M1K0, M2K0 (before January 2006), PM 6201, PM 8000 Express, PM 9000 Express, PM 9100, PM 9200P, and VS 800, plus Mindray PM 6000, PM 7000, PM 8000, and PM 9000 monitors. See the Specifications tab for the full list, including models that require the Masimo SpO2 option. Browse more SpO2 sensors and adapter cables.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray 0010-20-42594 Compatible SpO2 Adapter Cable for Nellcor OxiSmart Sensors, 6-Pin, 7.9 ft
$50.00The Mindray 0010-20-42594 compatible SpO2 adapter cable (SKU SA-052-24) is a reusable, aftermarket replacement (not OEM). It connects Nellcor OxiSmart-compatible SpO2 sensors to the compatible Mindray and Datascope monitors listed below.
Cable Type
SpO2 Adapter (Extension) Cable, ReusableSpO2 Technology
Nellcor OxiSmart CompatibleMonitor Connector
6-PinCable Length
7.9 ft (2.4 m)Replaces
Mindray 0010-20-42594Works with: Datascope Passport XG, DPM1 through DPM5, MEC 100, MEC 200, PM 600, PM 6000 (New), PM 9000 Express, VS 800, and VS 900, plus Mindray Accutorr V, Duo, Trio, Passport V, MEC 1000/1200/2000, PM 7000, PM 8000, PM 9000, and VS-800 monitors. See the Specifications tab for the full list. Browse more SpO2 sensors and adapter cables.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
-
Mindray 0600-00-0094 Compatible Adult Finger Clip SpO2 Sensor, Nellcor OxiSmart Compatible, Hard Shell, 9.8 ft
$72.00The Mindray 0600-00-0094 compatible adult SpO2 sensor (SKU SS-052-AF30) is a reusable, aftermarket replacement (not OEM). It is a hard-shell finger clip sensor for the compatible monitors with Nellcor OxiSmart SpO2 technology listed below.
Sensor Type
Hard-Shell Finger Clip, ReusablePatient Size
AdultSpO2 Technology
Nellcor OxiSmart CompatibleCable Length
9.8 ft (3.0 m)Replaces
Mindray 0600-00-0094, 512FLLWorks with: Datascope Passport XG, DPM1 through DPM5, MEC 100, MEC 200, PM 600, PM 6000 (New), PM 9000 Express, VS 800, and VS 900, plus Mindray Accutorr V, Duo, Trio, Passport V, MEC 1000/1200/2000, MEC-509B, PM 7000, PM 8000, PM 8000 Express, PM 9000, and VS-800 monitors. See the Specifications tab for the full list. Browse more SpO2 sensors and adapter cables.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.