  • GE Healthcare 411202-001 Compatible 5-Lead Multi-Link ECG Leadwire, Snap, Molded, 3 ft (0.9 m), AHA

    $50.00

    The GE Healthcare 411202-001 compatible 5-lead ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s Multi-Link 5-lead snap set (also sold as 2106383-001 and 2106381-001), built to match the original’s fit, form, and function.

    Leads
    5 (RA, LA, LL, RL, V)

    Trunk-End Connector
    GE Multi-Link, Molded

    Patient-End Connector
    Snap

    Lead Length
    3 ft (0.9 m)

    Color Code
    AHA (US)

    Patient Size
    Adult/Pediatric

    Construction
    Shielded, Reusable, Latex-Free

    Works with: GE CARESCAPE B450, B650, and B850; Dash 3000, 4000, and 5000; Solar 8000 and 9500; Tram modules; ApexPro CH; Datex-Ohmeda Aestiva/5 and Unity; and more. See the Specifications tab for the full list. Browse more ECG/EKG cables and leadwires.

    IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • GE Healthcare 2106389-001 / 412681-001 Compatible 5-Lead Multi-Link ECG Leadwire, Grabber/Pinch, Molded, 3 ft (0.9 m), AHA

    $50.00

    The GE Healthcare 2106389-001 compatible 5-lead ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s Multi-Link 5-lead grabber set (also sold as 412681-001), built to match the original’s fit, form, and function.

    Leads
    5 (RA, LA, LL, RL, V)

    Trunk-End Connector
    GE Multi-Link, Molded

    Patient-End Connector
    Grabber/Pinch Clips

    Lead Length
    3 ft (0.9 m)

    Color Code
    AHA (US)

    Patient Size
    Adult/Pediatric

    Construction
    Shielded, Reusable, Latex-Free

    Works with: GE CARESCAPE B450, B650, and B850; Dash 3000, 4000, and 5000; Solar 8000 and 9500; Tram modules; ApexPro CH; Datex-Ohmeda Aestiva/5 and Unity; and more. See the Specifications tab for the full list. Browse more ECG/EKG cables and leadwires.

    IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • GE Healthcare 2017008-001 Compatible Dual-Tube NIBP Air Hose, Adult/Pediatric, 12 ft (3.6 m)

    $50.00

    The GE Healthcare 2017008-001 compatible NIBP air hose is a reusable, aftermarket replacement (not OEM) for GE’s dual-tube adult/pediatric blood pressure hose, built to match the original’s fit, form, and function.

    Hose Type
    Dual-Tube

    Monitor-End Connector
    GE Adult Black Block

    Cuff-End Connectors
    Dual Twist-Lock (for Female Cuff Fittings)

    Hose Length
    12 ft (3.6 m)

    Patient Size
    Adult/Pediatric

    Construction
    PVC, Reusable, Latex-Free

    Works with: GE Dash 2000–5000, CARESCAPE B450/B650/B850, Solar, Tram, Corometrics 120/250/259 series, Datex-Ohmeda Aespire 7900, and more. See the Specifications tab for the full list. Browse more NIBP hoses and accessories.

    IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • GE Healthcare 9461-217 Compatible Dual-Tube NIBP Air Hose, Adult/Pediatric, Screw Cuff Connection, 8.2 ft (2.5 m)

    $50.00

    The GE Healthcare 9461-217 compatible NIBP air hose is an aftermarket replacement (not OEM) for GE’s dual-tube adult/pediatric blood pressure hose, built to match the original’s fit, form, and function.

    Hose Type
    Dual-Tube

    Monitor-End Connector
    GE Adult Black Block

    Use With
    2-Tube Screw-Type Cuffs

    Hose Length
    8.2 ft (2.5 m)

    Patient Size
    Adult/Pediatric

    Works with: GE Dash 2000–5000, CARESCAPE B105/B125/B450/B650/B850, Dinamap B105/B125, Procare B40, Solar, Tram, Corometrics 120/250/259 series, Datex-Ohmeda Aespire 7900, and more. See the Specifications tab for the full list. Browse more NIBP hoses and accessories.

    IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • Critikon/GE Compatible NIBP Air Hose, Adult/Pediatric Dual-Tube, 8 ft | 107365

    $50.00

    The GE Healthcare / Critikon 107365 compatible NIBP air hose is a reusable, aftermarket replacement (not OEM) adult/pediatric dual-tube hose for GE Healthcare, Critikon, and Dinamap non-invasive blood pressure monitors, built to maintain a secure, leak-free air path between the monitor and the cuff.

    Tube Configuration
    Dual-Tube

    Patient Size
    Adult/Pediatric

    Hose Length
    8 ft (2.5 m)

    Cuff Connector
    Threaded / Screw

    Connects To
    GE / Critikon / Dinamap NIBP monitors

    Lifecycle
    Reusable

    Replaces
    GE Healthcare / Critikon / Dinamap 107365

    Works with: select GE Healthcare / Critikon Dinamap Pro, ProCare, and Compact models, the MPS, and the Carescape B650, V100, and VC150. See the Specifications tab for the full list.

    IPR Medical buys, sells, repairs, and stocks parts for GE Healthcare, Critikon, and Dinamap patient monitoring systems. Call 855-477-8866 or email cs@iprmed.com.

  • Datex-Ohmeda 877235 Compatible NIBP Air Hose, Adult/Pediatric, Dual Tube, 8.2 ft (2.5 m)

    $50.00

    Datex-Ohmeda 877235 Compatible NIBP Air Hose (SKU BPH-AD25-13-1011) is a compatible aftermarket replacement (not OEM) for the Datex-Ohmeda 877235. It is a reusable adult/pediatric dual-tube blood pressure hose, 8.2 ft (2.5 m) long.

    Replaces
    Datex-Ohmeda / GE Healthcare 877235

    Patient Size
    Adult/Pediatric

    Tubing
    Dual Tube (2-Tube)

    Used with Cuff
    2-Tube Mated Submin Cuff

    Hose Length
    8.2 ft (2.5 m)

    Lifecycle
    Reusable

    Works with: select Datex-Ohmeda monitors such as the Cardiocap, S/5, AS/3, and CS/3, GE Healthcare / Marquette Eagle, Solar, and Tram models, and the Omron / Colin VP-1000/2000. See the Specifications tab for the full compatibility list.

    IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • Datex-Ohmeda / GE Compatible Adult/Pediatric Dual-Tube NIBP Air Hose, 11.8 ft (3.6 m) – 9461-214

    $50.00

    The Datex-Ohmeda / GE Healthcare 9461-214 compatible adult/pediatric dual-tube NIBP air hose (SKU BPH-AD36-13-09M) is a reusable aftermarket replacement (not OEM) built to OEM fit, form, and function for use with 2-tube adult and pediatric cuffs with screw (threaded) connectors.

    Hose Type
    Dual Tube

    Patient Size
    Adult / Pediatric

    Hose Length
    11.8 ft (3.6 m)

    Compatible Cuff Type
    2-Tube Adult/Pediatric Cuff with Screw (Threaded) Connectors

    Lifecycle
    Reusable

    Packaging
    1 Hose per Bag

    Replaces
    Datex-Ohmeda / GE Healthcare 9461-214

    Works with: Datex-Ohmeda S/5, AS/3, CS/3, Cardiocap II, Cardiocap/5, and Light monitors; GE Marquette Solar, Eagle 4000, and Tram 100 through 350 series; GE Corometrics 120 Series; and Criticare/CSI 500 and 507. Browse our full line of compatible NIBP hoses and cuffs.

    IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda and GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • Mindray 0010-20-42594 Compatible SpO2 Adapter Cable for Nellcor OxiSmart Sensors, 6-Pin, 7.9 ft

    $50.00

    The Mindray 0010-20-42594 compatible SpO2 adapter cable (SKU SA-052-24) is a reusable, aftermarket replacement (not OEM). It connects Nellcor OxiSmart-compatible SpO2 sensors to the compatible Mindray and Datascope monitors listed below.

    Cable Type
    SpO2 Adapter (Extension) Cable, Reusable

    SpO2 Technology
    Nellcor OxiSmart Compatible

    Monitor Connector
    6-Pin

    Cable Length
    7.9 ft (2.4 m)

    Replaces
    Mindray 0010-20-42594

    Works with: Datascope Passport XG, DPM1 through DPM5, MEC 100, MEC 200, PM 600, PM 6000 (New), PM 9000 Express, VS 800, and VS 900, plus Mindray Accutorr V, Duo, Trio, Passport V, MEC 1000/1200/2000, PM 7000, PM 8000, PM 9000, and VS-800 monitors. See the Specifications tab for the full list. Browse more SpO2 sensors and adapter cables.

    IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • Mindray 0010-30-42625 Compatible SpO2 Adapter Cable for Masimo LNCS Sensors, 6-Pin, 7.9 ft

    $50.00

    The Mindray 0010-30-42625 compatible SpO2 adapter cable (SKU SA-052M-24LS) is a reusable, aftermarket replacement (not OEM). It connects Masimo LNCS-compatible SpO2 sensors to the compatible Mindray and Datascope monitors listed below.

    Cable Type
    SpO2 Adapter (Extension) Cable, Reusable

    SpO2 Technology
    Masimo LNCS Compatible

    Monitor Connector
    6-Pin

    Cable Length
    7.9 ft (2.4 m)

    Replaces
    Mindray 0010-30-42625, 115-023136-00

    Works with: Datascope DPM3, DPM4, DPM5, M1K0, M2K0 (before January 2006), PM 6201, PM 8000 Express, PM 9000 Express, PM 9100, PM 9200P, and VS 800, plus Mindray PM 6000, PM 7000, PM 8000, and PM 9000 monitors. See the Specifications tab for the full list, including models that require the Masimo SpO2 option. Browse more SpO2 sensors and adapter cables.

    IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • Mindray 0012-00-1261-01 Compatible 5-Lead ECG Leadwire Set, AHA, Snap, Shielded, 3 ft (0.9 m)

    $50.00

    The Mindray 0012-00-1261-01 compatible 5-lead ECG leadwire set (SKU EL-MR5-90S-A) is a reusable, aftermarket replacement (not OEM). It has shielded limb and chest leads, snap ends, and AHA color coding, and it connects to a Mindray or Datascope 3/5-lead ECG trunk cable.

    Lead Count
    5-Lead (Limb and Chest Leads)

    Standard
    AHA (RA White, LA Black, RL Green, LL Red, V Brown)

    Electrode Ends
    Snap

    Lead Length
    3 ft (0.9 m), Shielded

    Lifecycle
    Reusable

    Replaces
    Mindray / Datascope 0012-00-1261-01, 0012-00-1261-02, 0012-00-1261-03, 0010-30-42735, and more

    Works with: Mindray and Datascope Passport, Spectrum, Trio, BeneView, BeneVision, BeneHeart, DPM, iMEC, cPM, ePM, and PM-series monitors, plus Edan iM-series and Midmark Cardell Touch (see the Specifications tab for the full list). Browse more ECG cables and leadwires.

    IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • Mindray 0012-00-1262-01 Compatible 5-Lead ECG Leadwire Set, AHA, Grabber/Pinch, Shielded, 3 ft (0.9 m)

    $50.00

    The Mindray 0012-00-1262-01 compatible 5-lead ECG leadwire set (SKU EL-MR5-90G-A) is a reusable, aftermarket replacement (not OEM). It has shielded limb and chest leads, grabber (pinch) ends, and AHA color coding, and it connects to a Mindray or Datascope 3/5-lead ECG trunk cable.

    Lead Count
    5-Lead (Limb and Chest Leads)

    Standard
    AHA (RA White, LA Black, RL Green, LL Red, V Brown)

    Electrode Ends
    Grabber / Pinch

    Lead Length
    3 ft (0.9 m), Shielded

    Lifecycle
    Reusable, Latex-Free

    Replaces
    Mindray / Datascope 0012-00-1262-01, 0012-00-1262-02, 0012-00-1262-03, 0010-30-42727, and more

    Works with: Mindray and Datascope Passport, Spectrum, Trio, BeneView, BeneVision, BeneHeart, DPM, iMEC, cPM, ePM, PM-series, Expert, and MPM monitors, plus Edan X12 and iM-series and Midmark Cardell Touch (see the Specifications tab for the full list). Browse more ECG cables and leadwires.

    IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

  • Mindray 0012-00-1503-03 Compatible 5-Lead Mobility ECG Leadwire Set, AHA, Snap, Shielded, 3 ft (0.9 m)

    $50.00

    The Mindray 0012-00-1503-03 compatible 5-lead mobility ECG leadwire set (SKU EL-DT5-90S-A) is a reusable, aftermarket replacement (not OEM). It has shielded limb and chest leads, snap ends, and AHA color coding, and it connects to a Mindray mobility-style 3/5-lead ECG trunk cable.

    Lead Count
    5-Lead (Limb and Chest Leads)

    Standard
    AHA (RA White, LA Black, RL Green, LL Red, V Brown)

    Electrode Ends
    Snap

    Trunk Connector
    Mindray Mobility Style

    Lead Length
    3 ft (0.9 m), Shielded

    Lifecycle
    Reusable, Latex-Free

    Replaces
    Mindray / Datascope 0012-00-1503-03, 0012-00-1503-01, 0012-00-1503-02, and more

    Works with: Mindray and Datascope Passport 2, 8, 12, 12m, 17m and V, plus V12, V21, Spectrum, DPM 6 and 7, Panorama, T1, BeneVision N-series, cPM, ePM, and uMEC monitors (see the Specifications tab for the full list). Browse more ECG cables and leadwires.

    IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.