Welch Allyn 008-0864-00 Compatible Adult/Pediatric NIBP Air Hose, 1-Tube, Female Threaded Plug, 5.9 ft (1.8 m)
The Welch Allyn 008-0864-00 compatible NIBP air hose (SKU BPH-AS18-09M-10) is a reusable aftermarket replacement (not OEM) with a 5.9 ft (1.8 m) single-tube design and a female threaded BP plug, for use with a 1-tube female Submin cuff on adult and pediatric patients.
| Patient Size | Adult/Pediatric |
| Tube Configuration | 1-Tube (Single Tube) |
| BP Plug | Female Threaded |
| Used with Cuff | 1-Tube Female Submin Cuff |
| Hose Length | 5.9 ft (1.8 m) |
| Replaces | Welch Allyn 008-0864-00 |
Works with: select Welch Allyn, MEK, and Draeger models. See the Specifications tab for the full list. Browse more NIBP hoses and accessories.
IPR Medical buys, sells, repairs, and stocks parts for NIBP hoses and the monitors they connect to. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | BPH-AS18-09M-10 |
| Replaces OEM Part | Welch Allyn 008-0864-00 |
| Category | Cables & Sensors > NIBP |
| Hose Type | BP Air Hose |
| Patient Size | Adult/Pediatric |
| Tube Configuration | 1-Tube (Single Tube) |
| BP Plug | Female Threaded |
| Used with Cuff | 1-Tube Female Submin Cuff |
| Hose Length | 5.9 ft (1.8 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Draeger | Narkomed 4 |
| MEK | MP 700, MP 1000 |
| Welch Allyn | 42NTB, 53N00, 53N0P, 53NT0, 53NTP, 53S00, 53S0P, 53ST0, 53STP, 530T0, 530TP, 1500, 5300P, 53000, Propaq 102, Propaq 104, Propaq 106-EL, Propaq CS, Propaq Encore, Propaq LT, Spot Vital Signs |
| Welch Allyn (with Nellcor SpO2 Option) | Propaq CS |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Welch Allyn | 008-0864-00 |
IPR Medical buys, sells, repairs, and stocks parts for blood pressure air hoses and patient monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Welch Allyn, Nellcor, or any other manufacturer or supplier named on this page. Welch Allyn, Nellcor, Propaq, Spot Vital Signs, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Welch Allyn 008-0864-00 Compatible NIBP Air Hose?
The IPR Medical BPH-AS18-09M-10 is a compatible aftermarket (not OEM) NIBP air hose that replaces the Welch Allyn 008-0864-00. Intended for reuse with adult and pediatric patients, it is a 5.9 ft (1.8 m) single-tube hose with a female threaded BP plug, and it is used with a 1-tube female Submin cuff.
Compatible Monitor Models
Most of the compatibility list for this hose belongs to Welch Allyn: it names select Welch Allyn models such as the Propaq 104, Propaq CS, Propaq Encore, Spot Vital Signs, 1500, and 53NTP. Select MEK models (the MP 700 and MP 1000) and the Draeger Narkomed 4 are listed as well. One Welch Allyn configuration is also listed with an SpO2 option and has its own row. Before you order, look up your monitor in the table of compatible models on the Specifications tab.
Design and Construction
This hose runs a single tube for 5.9 ft (1.8 m). Its BP plug is designated female threaded, and it is matched to 1-tube female Submin cuffs. It is reusable and packed one per bag; clean it between patients as your facility protocol directs, and check the threaded plug for damage each time you reconnect it.
When to Replace Your Welch Allyn Compatible NIBP Air Hose
A threaded plug that has been cross-threaded, flattened, or cracked can stop sealing, so start any inspection there. Then work along the tubing for splits, abrasion, hardened or sticky sections, and kinks that will not relax. Measurements that abort, cuffs that inflate slowly, and recurring leak alarms all suggest the hose is losing air; a known-good hose on the same monitor will confirm it.
Cross Reference and Interchange Part Numbers
Welch Allyn 008-0864-00 is the only interchange number on record for this hose, and it is also the OEM part the BPH-AS18-09M-10 replaces. You will see it as the single Welch Allyn entry under Cross Reference / Interchange Part Numbers, near the bottom of the Specifications tab.
Why Source NIBP Air Hoses from IPR Medical?
Welch Allyn compatible hoses like this one fall within IPR Medical’s work of buying, selling, repairing, and stocking parts for patient monitoring equipment and infusion pumps. IPR Medical holds ISO 9001:2015 certification as an independent service organization, with repairs done in-house by staff technicians. Reach us at 855-477-8866 or view more NIBP hoses and accessories.
IPR Medical buys, sells, repairs, and stocks parts for blood pressure air hoses and patient monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Welch Allyn, Nellcor, or any other manufacturer or supplier named on this page. Welch Allyn, Nellcor, Propaq, Spot Vital Signs, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews