IPR Medical

  • RecertifiedQuick View

    Baxter Auto Syringe AS40A Infusion Pump

    $995.00

    The Baxter Auto Syringe AS40A is a compact, single-channel syringe infusion pump designed for accurate continuous or intermittent delivery of fluids and medications. It supports IV, intra-arterial, epidural, and subcutaneous routes, accepts standard disposable syringes from 1 mL to 60 mL across three manufacturers, and operates on internal rechargeable battery or AC charger for bedside, transport, and ambulatory use.

    Pump Type
    Single-channel syringe infusion pump

    Flow Rate Range
    0.01 to 360 mL/hr (syringe-dependent)

    Compatible Syringes
    B-D Plastipak, Monoject, and Terumo, 1–60 mL

    Battery
    Internal NiCd rechargeable pack; 12 hr at 2 mL/hr (60 mL syringe)

    Notable Features
    Bolus, titration, auto syringe recognition, auto-lock, configurable occlusion sensitivity

    Looking for a newer alternative? Consider upgrading to the Baxter AS50 — the direct next-generation successor sharing the same compact form factor and syringe compatibility, with an extended flow rate ceiling of 438 ml/h and an upgraded rechargeable battery — or the Medfusion 3500 Version 6, a modern syringe pump with a built-in drug library options and full third-party service support.

    Please note: Baxter has ended manufacturer support for the AS40A. IPR Medical buys, sells, and repairs the Baxter AS40A and stocks replacement parts to keep these pumps performing reliably in the field. Contact us at 855-477-8866 or cs@iprmed.com.

  • Baxa Microfuse Dual Rate

    $995.00

    The Baxa MicroFuse Dual Rate Infuser is designed for small volume infusions (SVI) of intravenous fluids. It delivers fluids diluted in 1 to 100 mL volumes over 1 to 120 minutes intermittently. Using syringe infusion, it offers an efficient alternative to gravity and minibag IV systems. The MicroFuse Infuser provides reliable, fixed-rate infusion, ensuring consistent medication delivery. It utilizes cost-effective materials, reducing waste and setup time. This system minimizes administration labor, enhancing clinical efficiency. Its compact design is ideal for precise and controlled small volume infusions. Overall, the Baxa MicroFuse Dual Rate Infuser is a dependable and efficient solution for SVI needs.

     

  • Recertified
    Doppler 915
    Quick View

    Parks Medical Ultrasonic Doppler Flow Detector 915-BL

    $895.00

    The Parks Medical Electronics Model 915-BL is the dual-frequency Doppler in the Parks lineup — purpose-built for anesthesiology and surgical environments where a single-frequency unit simply isn’t enough. It houses two independent Doppler channels in one compact case: a low-frequency ~2.25 MHz precordial channel for detecting the passage of air emboli in the heart, and a high-frequency 8–9 MHz channel for arterial blood flow detection and systolic blood pressure measurement. This combination makes the 915-BL the go-to instrument for neurosurgery, cardiac procedures, seated craniotomies, and any case where venous air embolism (VAE) monitoring is part of the anesthetic plan.

    On top of dual-frequency capability, the 915-BL includes a cautery suppressor with a controllable threshold — a step up from the fixed suppressor found in the 811-BL — allowing the clinician to dial in the suppression level to match the specific interference environment rather than applying a blanket cutoff.

    IPR Medical is an authorized Parks Medical Doppler repair facility and one of only a few such centers in the country. Working closely with the Parks Medical technical team, IPR Medical buys, sells, repairs, and stocks genuine replacement parts for the Parks Medical 915-BL Doppler — including batteries, probes, and chargers. Whether you need a factory-quality repair, a certified refurbished unit, or expert Parks Doppler service you can trust, contact IPR Medical at 855-477-8866 or cs@iprmed.com.

    Probes are not included in the purchase of the dopplers and are sold separately.

  • -31%
    Alaris 8015 PC UnitQuick View

    BD Alaris 8015 PC Unit (5.7″ Display)

    Original price was: $1,295.00.Current price is: $895.00.

    The BD Alaris 8015 PC Unit is the brain of one of the most widely deployed modular infusion systems in North American hospitals. It doesn’t deliver medication on its own — it’s the command center. Attach up to four Alaris infusion and monitoring modules (pump, syringe, PCA, SpO2, EtCO2) to a single PCU, and it gives every one of them a unified color interface, a shared drug library, and one place to program, monitor, and alarm. For facilities managing complex patients on multiple simultaneous infusions, that common user interface is a real operational advantage — less device-switching, less cognitive load, fewer programming errors.

    What makes the Alaris system worth running is Guardrails Suite MX. Up to 30 patient-specific care area profiles, each with its own drug library, soft and hard dose limits, concentration guidelines, and IV fluid entries. The library runs on every device in the fleet, wirelessly updated through Alaris Systems Manager, and the CQI Reporter pulls infusion event data for ongoing safety improvement.
    Also available: BD Alaris 8015 with 4.7″ display

    The 5.7″ display model is the larger-screen version of the 8015, and if your staff has used either the 4.7″ or 5.7″ variants, they’ll recognize the workflow instantly. IPR Medical buys, sells, repairs, and stocks parts for the BD Alaris 8015. Call us at 855-477-8866 or email cs@iprmed.com.

  • -10%
    RecertifiedBaxter 6301 Infusion PumpQuick View

    Baxter Flo-Gard 6301

    Original price was: $995.00.Current price is: $895.00.

    The Baxter Flo-Gard 6301 is a dual-channel linear peristaltic volumetric infusion pump that does the work of two conventional pumps in a single unit mounted to one IV pole. Each of its two independently programmable channels supports full primary and secondary infusion programs, a 10-step Programmed Delivery Profile, volume-time programming, automatic piggybacking, and a dedicated Flow Check display — making the 6301 one of the most capable pumps in the Flo-Gard family.

    Both channels share a single control interface with PUMP 1 and PUMP 2 selector keys, keeping the footprint compact while delivering the full feature set of the 6201 on each channel simultaneously. The device runs on 110/120V AC or its internal 12-volt sealed lead-acid battery — approximately 6 hours with one pump running, or approximately 4 hours with both running. Nurse call output, configurable hospital area designator, selectable downstream occlusion and air-in-line sensitivity, five-hour data memory, and an automatic self-test on startup round out a pump built for demanding clinical environments.

    The 6301 is an older, discontinued pump, but facilities that rely on it value the space savings and operational efficiency of dual-channel infusion in a single device. IPR Medical maintains a large inventory of Flo-Gard 6301 parts to keep your fleet running strong.

  • -15%
    RecertifiedQuick View

    Philips IntelliVue MP30 Patient Monitor | 10.4″ Touchscreen, 12-Lead ECG

    Original price was: $995.00.Current price is: $845.95.

    The Philips IntelliVue MP30 (M8002A) is a compact, touchscreen-equipped bedside patient monitor designed for intermediate care, ambulatory surgery, post-operative care, special procedures, lower acuity environments, and in-hospital patient transport. Sharing the common IntelliVue platform and user interface with the broader MP-series family, the MP30 delivers powerful clinical measurement capability — including conventional diagnostic 12-lead ECG, multi-lead arrhythmia analysis, capnography, and SpO2 — in a portable package weighing less than 13.2 lbs combined with the Multi-Measurement Server (MMS) and battery. Wired and optional wireless networking connect the MP30 to the Philips IntelliVue Clinical Network and IntelliVue Information Center for enterprise-wide data continuity.

    Display
    10.4″ color TFT LCD, SVGA resolution; touchscreen standard

    Waveforms
    Up to 4 simultaneously (USA); 12-lead ECG screen available

    User Interface
    Touchscreen (standard); integrated navigation point; optional Remote SpeedPoint

    Patient Population
    Adult, Pediatric, Neonatal

    Battery Operation
    Up to 5 hours with dual lithium-ion batteries (M4605A)

    Weight (system)
    Less than 13.2 lbs (monitor + MMS + battery)

    Connectivity
    Wired LAN standard; optional IEEE 802.11 a/b/g wireless

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue MP30. Contact us at 855-477-8866 or cs@iprmed.com.

  • -17%
    Quick View

    Alaris 8120 PCA Module

    Original price was: $995.00.Current price is: $825.00.

    The Alaris 8120 is a PCA pump module designed for patient-controlled delivery of pain management medications. It utilizes syringe-based technology with secure drug access and easily attaches to the Alaris PC. This module is compatible with the Alaris PC Unit and other Alaris System modules. The Alaris 8120 uses standard or pre-filled, single-use disposable syringes with luer-lock connectors. It also employs administration sets with anti-siphon valves for added safety. The system ensures precise and secure medication delivery. Its design enhances patient control over pain management. Overall, the Alaris 8120 provides a reliable and integrated solution for PCA therapy.

     

    Brand new units may be available. Please contact us directly for more information.

  • -11%
    RecertifiedQuick View

    Baxter Flo-Gard 6200

    Original price was: $895.00.Current price is: $795.00.

    The Baxter Flo-Gard 6200 is a single-channel volumetric infusion pump built for reliable, accurate intravenous delivery of a wide range of fluids — including blood and fat emulsions — across primary and secondary infusion programs. Operating on standard 115 VAC power or its self-contained rechargeable battery, it delivers flow rates from 1 to 999 mL/hr in 1 mL/hr increments with a VTBI range of 1 to 9,999 mL. Automatic piggybacking switches seamlessly from the secondary program back to the primary when secondary infusion completes, and a built-in safety clamp prevents accidental free flow any time the pump door is opened.

    The Flo-Gard 6200 is an older pump — discontinued by Baxter — but it remains one of the most straightforward, dependable large-volume pumps in clinical use today. Hospitals, long-term care facilities, outpatient clinics, and veterinary practices continue to rely on them for good reason: they are simple to load, simple to program, and built to last.

    IPR Medical maintains a large inventory of Flo-Gard 6200 parts — including batteries, fuses, pump mechanisms, power cords, and more — to keep your fleet running strong. Whether you need a single unit serviced or a supply of components to support ongoing maintenance, we have what you need.

  • Recertified
    Quick View

    Parks Medical Ultrasonic Doppler Flow Detector 811-BL

    $795.00

    The Parks Medical Electronics Model 811-BL is a non-directional ultrasonic Doppler flow detector built on the same proven 811-series platform that has been in continuous clinical use for over 50 years — with one critical addition for surgical environments: a built-in cautery suppressor. The cautery suppressor filters out electromagnetic interference generated by electrosurgical units, keeping the Doppler signal clean and audible during active cautery use. This makes the 811-BL the preferred choice over the standard 811-B anywhere electrocautery is in routine use, particularly in operating rooms and interventional settings. Like its siblings, it uses a factory-tuned 8–9 MHz probe to detect blood flow acoustically, enabling systolic blood pressure measurement at sites where a stethoscope cannot reach and detection of pulses too faint for conventional auscultation.

    The 811-BL features a built-in speaker for immediate audio feedback, an auxiliary headphone jack for private monitoring or recording, and a rechargeable 12V sealed lead-acid battery with a low-battery indicator lamp and a safety circuit that prevents operation while charging. Probe options include standard pencil, skinny pencil (for small vessels), adult flat, and infant flat configurations — the infant flat probe is the most commonly used probe in veterinary applications.

    IPR Medical is an authorized Parks Medical Doppler repair facility and one of only a few such centers in the country. Working closely with the Parks Medical technical team, IPR Medical buys, sells, repairs, and stocks genuine replacement parts for the Parks Medical 811-BL Doppler — including batteries, probes, and chargers. Whether you need a factory-quality repair, a certified refurbished unit, or expert Parks Doppler service you can trust, contact IPR Medical at 855-477-8866 or cs@iprmed.com.

    Dopplers are sold based on frequency without the probe. Please let us know if you also need a probe with your Doppler.

  • -11%
    Recertified
    Ultrasonic Doppler Flow Detector
    Quick View

    Parks Medical Ultrasonic Doppler Flow Detector 811-BTS

    Original price was: $895.00.Current price is: $795.00.

    The Parks Medical Electronics Model 811-BTS is a non-directional ultrasonic Doppler flow detector built on the same proven 811-series platform that has been in continuous clinical use for over 50 years — with one practical addition for everyday clinical use: a built-in auto-shutoff. The auto-shutoff automatically powers the unit down after a period of inactivity, extending battery life and eliminating the all-too-common issue of a Doppler being left on between patients and found with a depleted battery at the next use. In every other respect the 811-BTS shares the full capability of the 811-B — using a factory-tuned 8–9 MHz probe to detect blood flow acoustically, enabling systolic blood pressure measurement at sites where a stethoscope cannot reach and detection of pulses too faint for conventional auscultation.

    The 811-BTS features a built-in speaker for immediate audio feedback, an auxiliary headphone jack for private monitoring or recording, and a rechargeable 12V sealed lead-acid battery with a low-battery indicator lamp and a safety circuit that prevents operation while charging. Probe options include standard pencil, skinny pencil (for small vessels), adult flat, and infant flat configurations.

    IPR Medical is an authorized Parks Medical Doppler repair facility and one of only a few such centers in the country. Whether you need a factory-quality repair, a certified refurbished unit, or expert Parks Doppler service you can trust, contact IPR Medical at 855-477-8866 or cs@iprmed.com.

    Dopplers are sold based on frequency without the probe. Please let us know if you also need a probe with your Doppler.

  • Recertified
    811-B Flow Detector
    Quick View

    Parks Medical Ultrasonic Doppler Flow Detector 811-B

    $795.00

    The Parks Medical Electronics Model 811-B is one of the most trusted non-directional Doppler flow detectors in clinical practice — a workhorse device that has been in continuous use for over 50 years. It uses a factory-tuned 8–9 MHz probe to detect blood flow acoustically, making it possible to measure systolic blood pressure at sites where a stethoscope cannot reach and to detect pulses too faint for conventional auscultation. Whether you’re measuring ankle-brachial pressures, monitoring peripheral arterial flow intraoperatively, or conducting a quick vascular screen at bedside, the 811-B delivers reliable signal with minimal setup. It’s used widely in operating rooms, emergency departments, recovery rooms, ICUs, vascular clinics, urology, pediatrics, and veterinary practice.

    The internal speaker provides immediate audio feedback, and an auxiliary headphone jack allows for private monitoring or recording. Probe options include standard pencil, skinny pencil (for small vessels), adult flat, and infant flat configurations — the infant flat probe is the most commonly used probe in veterinary applications. Parks manufactures the 811-B in the USA at their facility in Aloha, Oregon, and the device carries a one-year warranty on the unit and six months on probes.

    IPR Medical is an authorized Parks Medical Doppler repair facility and one of only a few such centers in the country. Working closely with the Parks Medical technical team, IPR Medical buys, sells, repairs, and stocks genuine replacement parts for the Parks Medical 811-B Doppler — including batteries, probes, and chargers. Whether you need a factory-quality repair, a certified refurbished unit, or expert Parks Doppler service you can trust, contact IPR Medical at 855-477-8866 or cs@iprmed.com.

    Dopplers are sold based on the frequency without the probe. Please let us know if you also need a probe with your doppler.

  • -50%
    Recertified
    Medfusion 3500 Infusion PumpRecertified (refurbished) Medfusion 3500 syringe pump from IPR Medical
    Quick View

    Smiths Medical Medfusion 3500 Syringe Pump | V6, PharmGuard

    Original price was: $1,595.00.Current price is: $795.00.

    The Smiths Medical Medfusion 3500 is a single-syringe infusion pump built for critical-care precision across patients of all ages, from neonatal to adult. Running Software Version 6 (V6) with PharmGuard medication safety software, it pairs a configurable drug library and hard/soft dose limits with FlowSentry rapid occlusion detection, giving clinicians both programming safety and early pressure awareness. With a delivery range of 0.01 to 1130 mL/hr at a nominal ±2% accuracy and compatibility with 1–60 mL syringes from five major manufacturers, the 3500 V6 remains a workhorse in NICU, PICU, OR, and ICU settings on the secondary market.

    **SALE – Sold without accessories. Pump includes a power cord and a 1-year warranty. All accessories, including the pole clamp, are sold separately. Compatibility with existing systems must be confirmed by the buyer. For any information regarding the Drug Library, please contact our team directly.** Offer valid for a Limited Time Only.

    Pump Type
    Single-syringe infusion pump (1–60 mL)

    Flow Rate Range
    0.01 to 1130 mL/hr

    Delivery Accuracy
    Nominal ±2% (± syringe accuracy)

    Safety Software
    PharmGuard drug library; FlowSentry occlusion detection

    Patient Population
    Neonatal, pediatric, and adult

    Power & Weight
    Rechargeable NiMH + AC; ~3.8 lbs

    IPR Medical buys, sells, repairs, and stocks parts for the Smiths Medical Medfusion 3500 (V6) Syringe Pump. Contact us at 855-477-8866 or cs@iprmed.com.

    Also available from IPR Medical:
    Medfusion 4000 — next-generation pump on the same platform  |
    Medfusion 2010i — ambulatory syringe pump, 15 delivery modes  |
    B. Braun Perfusor Space (Version U) — transport-rated syringe pump

     

    Medfusion syringe pumps are sold without a configured drug library. PharmGuard® Medication Safety Software is required to build and load custom drug libraries. If you need a custom drug library configured for your facility, contact us for available options and pricing.