CADD Legacy Plus
The CADD-Legacy™ PLUS ambulatory infusion pump provides measured medication therapy to patients in hospital or outpatient settings. The CADD-Legacy™ PLUS pump is indicated for intravenous, intra-arterial, subcutaneous, intraperitoneal, epidural space, or subarachnoid space infusion. The pump is intended for therapies that require a continuous or intermittent rate of infusion.
Features
- Easy to read display
- Cassette detection
- Occlusion detection
- Reliable and Durable
- Programming flexibility
- Air-in-Line detector with Off, High- and Low-sensitivity settings
- ON/OFF key allows pump to be put in a low-power state to save battery life
- Event memory of the last 1,000 events in the pump’s history
-
Dimensions: 1.6″ W X 3.8″ H X 4.4″ L
- Weight: 0.86 lbs. (13.8 oz), including 2 AA batteries and empty medication reservoir
- Moisture Protection: Splash-proof (IPX4)
- Power: Two AA alkaline batteries; AC Adapter
- Battery Capacity: The expected life of 2 AA batteries is 15 hours at 125 ml/hour, or approximately 14 days at 10 ml/day (nominal).
- Accuracy: ± 6% (nominal)
- Maximum Infusion Pressure: 40.0 psi
- Maximum Time to Occlusion Alarm: CADD® Administration Set with anti-siphon valve: 2.0 hours
- Operating Temperature: 35°F to 104°F (2°C to 40°C)
- Storage/Transportation Temperature: -4°F to 140°F (-20°C to 60°C)
- High Pressure Alarm: 26 ± 14 psi
- Maximum Volume Infused under Single Fault Condition: CADD® Administration Set with anti-siphon valve: 0.2 ml
- Delivery Rate during priming: Approximately 180 ml/hr
- Alarm Disabled during priming: Air Detector
Continuous Delivery Specifications:
- Reservoir Volume: 1 to 9999 or Not In Use; programmable in 1 ml increments, displayed in 0.1 ml increments (Default = 1.0 ml)
- Continuous Rate:1 to 125 ml/hr; programmable in 0.1 ml/hr increments (Default = 0.0 ml)
- Given: 0 to 99999.95 in 0.05 ml increments
Intermittent Delivery Specifications:
- Reservoir Volume: 1 to 9999 or Not In Use; programmable in 1 ml increments, displayed in 0.1 ml increments (Default = 1.0 ml)
- Dose Volume: 1 to 1000 ml programmable in 0.1 ml increments (Default = 0.0 ml)
- Dose Duration: Default = 30 min. Duration lasts 1 min to 24 hrs in the following increments:
- 1 minute for values between 1 min and 10 min
- 5 minutes for values above 10 min
- * Duration is limited by Dose Volume so that rate does not exceed 125 ml/hr.
- Dose Cycle: 10 min to 96 hrs in 5 minute increments. Default = 4 hrs
- KVO Rate: 0 to 125 ml/hr in 0.1 ml/hr increments. Default = 0 ml/hr
- Given: 0 to 99999.95 in 0.05 ml increments
- Dose Remaining: 1 minute increments
Alarms/Alerts:
Low battery power | Disposable not attached when run attempted |
Depleted battery power | Motor locked |
Battery dislodged | Upstream occlusion |
Pump stopped | Reservoir volume empty |
Pump fault | Program incomplete |
Low reservoir volume | Key stuck |
High delivery pressure | Disposable detached |
Air in line |
Download the operator’s Manual